GDTL AC Resonant Test System ya Jenereta
GDTL mndandanda wa AC Resonant Test System ya Majenereta angagwiritsidwe ntchito posintha inductance ya riyakitala, kapena kusintha njira yantchito yama frequency a resonant a dongosolo kuti akwaniritse resonance.Njira ziwirizi zingagwiritsidwe ntchito kukwaniritsa resonance.Mu njira yowonjezeretsa voteji, ngati resonant point ipatuka, imatha kupezeka ndendende ndi njira yosinthira pafupipafupi, yomwe imatsimikizira mtengo wapamwamba wa Q ndikuchepetsa mphamvu yamagetsi ndi kulemera kwa zida zoyesera.
●Kukula kwakung'ono, kulemera kopepuka poyerekeza ndi mulingo womwewo wamagetsi, jenereta yofananira ya AC kupirira zida zoyeserera voteji. Chida chimodzi sichiposa 60kg, chosavuta kusuntha.
●Mfundo zapamwamba za chipangizo chonsecho komanso ukadaulo watsopano waukadaulo & inductance modulation, onetsetsani kuti ma frequency a jenereta amapirira zofunikira pakuyesa kwamagetsi.Kuchuluka kwa ntchito.
●Okonzeka ndi 20Hz-300Hz gwero kusinthasintha kusintha.Chitetezo chabwino ndi mawonekedwe otuluka, kukhazikika kwakukulu.Ndi angapo ntchito mode, yosavuta kugwiritsa ntchito.
●Magetsi a 220V kapena 380V, osavuta kugwiritsa ntchito magetsi pamalopo.
●Mfundo ya Max.Q imapezeka ndendende ndi njira yoyamba yosinthira inductance ndikusintha pafupipafupi pafupipafupi, kupewa kupatuka kwa resonance chifukwa cha kukwera kwamagetsi;
●Kusintha kosinthika komanso kukulitsa mwamphamvu.Kukwaniritsa zofunikira zonse zoyeserera za capacitive test mumagetsi.
●Njira yoyesera ma frequency amphamvu kapena njira yoyeserera pafupipafupi.
●Zogwiritsa ntchito zambiri, zotsika mtengo.
●Ovoteledwa linanena bungwe voteji: 0 ~ 50kV (RMS) kapena pansipa.
●Kutulutsa pafupipafupi: 45 - 300Hz.
●Waveform: koyera sine wave, THD ≤ 1%.
●Max.mphamvu: 2000kVA kapena pansipa.
●Ntchito yozungulira: 15mins yogwira ntchito nthawi imodzi pakupanga mphamvu zonse.
●Quality factor: 10-40.
●Kusintha pafupipafupi kumva: 0.1HZ, kusakhazikika kwa <0.05%.
●Mphamvu: 220V kapena 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Mphamvu yolowera (V) | 380 |
Mphamvu yamagetsi (kV) | 0 - 50 |
Kuthekera (kVA) | 100 |
Kuchuluka kwa ntchito | Jenereta--kuthekera pansi 0.07-0.13 μF |
10 kV (300 mm² ) chingwe ≤ 1 km | |
Zosintha zazikulu | 50kV/1A Fixed reactor 1 seti |
50kV/1A Adjustable riyakitala 1 seti | |
Capacitive divider 50kV | |
GDTF-150/50 | |
Mphamvu yolowera (V) | 380 |
Mphamvu yamagetsi (kV) | 0 - 50 |
Kuthekera (kVA) | 150 |
Kuchuluka kwa ntchito | Jenereta--kuthekera pansi 0.13-0.2 μF |
10 kV (300 mm² ) chingwe ≤ 1.5 km | |
Zosintha zazikulu | 50kV/1.5A Fixed reactor 1 seti |
50kV/1.5A Adjustable riyakitala 1 seti | |
Capacitive divider 50 kV | |
GDTF- 225/50 | |
Mphamvu yolowera (V) | 380 |
Mphamvu yamagetsi (kV) | 0 - 50 |
Kuthekera (kVA) | 225 |
Kuchuluka kwa ntchito | Jenereta - mphamvu pansi 0.2-0.27 μF |
10 kV (300 mm² ) chingwe ≤ 2.5 Km | |
Zosintha zazikulu | 50kV/1.5A Fixed reactor 2 seti |
50kV/1.5A Adjustable riyakitala 1 seti | |
Capacitive divider 50 kV | |
GDTF- 360/60 | |
Mphamvu yolowera (V) | 380 |
Mphamvu yamagetsi (kV) | 0-60 |
Kuthekera (kVA) | 360 |
Kuchuluka kwa ntchito | Jenereta - mphamvu pansi 0.27-0.33 μF |
Zosintha zazikulu | 60kV/2A Fixed reactor 1 seti |
60kV/2A Adjustable riyakitala 1 seti | |
Capacitive divider 60kV |