GD3127 Series High Voltage Insulation Resistance Tester
GD3127 Series Insulation Resistance Tester imagwiritsidwa ntchito kwambiri pokonza zida zamagetsi mu thiransifoma, malo opangira magetsi, etc. Ndi oyenera kuchita muyeso wa kukana kutchinjiriza (IR), polarization index(PI), mayamwidwe chiŵerengero (DAR), ramp( RAMP), fyuluta (FR, 10s, 20s, 30s, 40s 4 zosankha), voteji (V), panopa (nA) yamitundu yonse ya zida zamagetsi apamwamba, kuphatikiza ma switchgear, ma transformer, ma reactor, ma capacitor, ma mota, ma jenereta ndi zingwe, ndi zina.
GD3127 Series ndiye chida chabwino kwambiri choyesera chodziwikiratu ndikupeza njira zodzitetezera kapena zolosera zam'tsogolo zomwe zidalephera kulephera.Ndikofunikira kwambiri kuonetsetsa kuti zinthu zili bwino komanso chitetezo cha anthu ndi zida zomwe zikugwira ntchito.Kagwiritsidwe kake kazinthu zamagetsi ndi chimodzi mwazizindikiro zofunika kuwunika mtundu wa kutchinjiriza, womwe umawonetsedwa ndi kuyesa kukana kukana.
●Max.nthawi yochepa> 5mA.
●Insulation resistance (IR), polarization index (PI), mayamwidwe ratio (DAR).
●Ramp (RAMP), fyuluta (FR), voliyumu (V).
●Kuwunika basi voteji moyo wa chinthu kuyeza, ndi basi kuletsa mayeso ngati voteji kuposa 36V, amene bwino amateteza chida ndi woyendetsa.
●Ntchito yowerengera nthawi, lemberani nthawi yoyeserera.
●Kutulutsa voteji yayikulu mukatha kuyeza, nthawi yotulutsa sipitilira masekondi 30.
●Makinawa amazimitsa ntchito.
●Chiwonetsero chachikulu cha madontho a LCD okhala ndi magwiridwe antchito okhazikika.
●Mapangidwe a zipolopolo zamitundu iwiri, zolimba komanso zolimba, kalasi yachitetezo IP65.
●Paketi yayikulu yowonjezeredwa ya lithiamu batire.
●Ntchito yosungira, imatha kusunga ma seti 1000 a data yeniyeni yoyeserera ndi tsiku loyesa ndi nthawi komanso nthawi yoyeserera.
●Ntchito yokweza, yokhala ndi mawonekedwe a USB, deta yojambulira imatha kutsitsidwa pakompyuta kuti ifufuze ziwerengero.
Ntchito | Insulation resistance(IR), polarization index(PI), mayamwidwe chiŵerengero (DAR), ramp(RAMP), fyuluta (FR, 10s, 20s, 30s, 40s 4 kusankha), voltage(V), panopa (nA) |
Magetsi | Zobwerezedwansolithiamu batire5.2Ayi |
Adavotera mphamvu | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Mphamvu yamagetsi akulondola | (5% -10%)±10 V |
Mtundu wa kuyeza kwa insulation | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
Short circuit panopa | > 5mA |
Polarization index (PI) | Inde |
Chiyerekezo cha mayamwidwe (DAR) | Inde |
Ramp (RAMP) mayeso mode | Yesani masitepe a 10% yamagetsi okonzedweratu mpaka voteji yokonzedweratu |
Zosefera zoyeserera | Zosankha zinayi za 10S, 20S, 30S, 40S |
Mayeso a Voltage | Mtundu: AC/DC 0V-1000V, kulondola:±5% pa±3V |
Mayeso apano | Mtundu: 0.01nA-7mA, kulondola:±5% pa±0.5nA |
Voltage Monitor | Yang'anirani mphamvu ya chinthu choyesedwa, yang'anirani momwe zimatulutsira pambuyo pa mayeso, ndikuletsa kuyesa pamene magetsi ndi aakulu kuposa 36V, tetezani chipangizocho ndi woyendetsa. |
Yesani nthawi | Jambulani nthawi yoyeserera, nthawi yake: 0s~9999s ku |
Kusungirako | Kusungirako zokha kwa data yoyesera ndi tsiku ndi nthawi, magulu onse a 1000 |
Kulankhulana | Kwezani data yoyeserera yosungidwa pakompyuta kudzera pa chingwe cholumikizira cha USB. |
Batiri | Pali chiwonetsero cha mulingo wa batri, kukumbutsa kuti mudzazilipira munthawi yomwe mphamvu ya batri ili yotsika |
Auto kuzimitsa ntchito | Kuzimitsa galimoto pakatha mphindi 15 |
Gulu la chitetezo | IP65/IP40 |
Insulation resistance | 50MΩ(1000V) (pakati pa mayeso ndi chipolopolo) |
Kupirira voltage | AC 3kV 50Hz 1min (pakati pa test circuit ndi shell) |
Miyezo | IEC61010-1, IEC61326-1 |
Ntchito kutentha ndi chinyezi | - 20℃ ~ +50℃ <80%RH |
Kusungirako kutentha ndi chinyezi | - 25℃ ~ +65℃80% RH |
Magetsi | 220V AC 50Hz |
kukula (mm) | 280(L) * 260(W)*160 (H) |
Kulemera | 4400g (kuphatikiza batire) |
Insulation resistance tester | 1 seti |
High voltage test waya (Yofiira) | 1 chidutswa |
Yesani waya(Wobiriwira) | 1 chidutswa |
Yesaniwaya(Wakuda) | 1 chidutswa |
Adaputala yamagetsi | 1 piece |
Wogwiritsa's chitsogozo | 1 kopi |
Yesanireport | 1 kopi |