GDC-9560B Power System Insulation Mafuta Gasi Chromatograph Analyzer
GDC-9560B Gas Chromatograph Analyzer ndikuwunika momwe mafuta amapangira mafuta pogwiritsa ntchito njira ya gasi chromatographic.Ndizothandiza kuweruza ngati zida zogwiritsira ntchito zili ndi vuto ngati kutentha kwambiri, kutulutsa kapena ayi, kuonetsetsa chitetezo cha gridi yamagetsi.Ndikofunikiranso kugwiritsidwa ntchito popanga zida zamafuta / mafuta kuti aziwunika zida zawo asanachoke kufakitale.
Ukadaulo wowunikira chromatography ya gasi ndi njira yolekanitsira ndikusanthula zosakaniza zamagulu angapo.Imagwiritsira ntchito kusiyana kwa mfundo yowira, polarity ndi adsorption coefficient ya gawo lililonse lachitsanzo mu ndime, kotero kuti zigawozo zimasiyanitsidwa ndi gawoli, ndipo zigawo zolekanitsa zimayesedwa bwino komanso mochuluka.
Chromatograph ya gasi imagwiritsa ntchito gasi ngati gawo la mafoni (gasi wonyamula).Pamene chitsanzocho chimatumizidwa ku jekeseni ndi vaporized, chimanyamulidwa ndi mpweya wonyamulira mzati yodzaza kapena capillary column chifukwa cha kutentha, polarity ndi adsorption coefficient ya chigawo chilichonse mu chitsanzo.Kusiyanitsa ndikuti zigawozo zimasiyanitsidwa ndi gawoli, ndiyeno zowunikira zomwe zimalumikizidwa ndi gawoli zimazindikiridwa motsatizana malinga ndi mawonekedwe a physicochemical a zigawozo, ndipo pamapeto pake zizindikiro zamagetsi zosinthidwa zimatumizidwa ku chromatographic workstation.Chromatogram ya gasi ya chigawo chilichonse imalembedwa ndikuwunikidwa ndi makina ogwiritsira ntchito chromatographic kuti apeze zotsatira zowunikira gawo lililonse.
●Imatengera mawonekedwe apamwamba a 10/100M osinthika a Efaneti olumikizirana ndi ma IP protocol stack, omwe amathandizira chidacho kuzindikira mosavuta kutumizirana kwa data mtunda wautali kudzera mu LAN yamkati ndi intaneti.Imathandizira kukhazikitsidwa kwa labotale komanso imathandizira ma labotale.Kukonzekera kumathandizira kasamalidwe ka deta yowunikira.
●Kupanga kwa 3 njira zolumikizira zodziyimira pawokha.Itha kulumikizidwa ndi makonzedwe am'deralo (laboratory), yabwino kwa oyang'anira kuti aziyang'anira momwe akugwirira ntchito ndikusanthula zotsatira.
●Malo ogwirira ntchito a NetChromTM omwe angasankhidwe amatha kuthandizira nthawi imodzi ma chromatograph angapo pokonza ndi kuwongolera deta, kufewetsa kasamalidwe ka zikalata komanso kuchepetsa ndalama zogulira labu la ogwiritsa ntchito komanso ndalama zogwirira ntchito.
●Dongosolo mu Chingerezi ndi Chitchaina, lomwe lingasinthidwe momasuka.
●Malo olamulira kutentha akhoza kutchulidwa momasuka ndi wogwiritsa ntchito, zomwe zimakhala zosavuta kwa ogwiritsa ntchito.
●Kugwiritsa ntchito multiprocessor parallel working mode, yokhazikika komanso yodalirika.Imakumana ndi kusanthula kwachitsanzo kovuta.Zokhala ndi zowunikira zosiyanasiyana zogwira ntchito kwambiri monga FID, TCD, ECD, ndi FPD.Mpaka mayesero anayi akhoza kuikidwa nthawi imodzi.Ndikothekanso kugwiritsa ntchito njira yowonjezera ya detector, yomwe ndi yabwino kugula ndikuyika zowunikira zina chida chikagulidwa.
●Chidacho chimagwiritsa ntchito mawonekedwe a modular, opangidwa ndikusinthidwa, osavuta kukweza ndikuteteza magwiridwe antchito a ndalama.
●Dongosolo latsopano lowongolera kutentha kwa microcomputer lili ndi kuwongolera kutentha kwambiri komanso kudalirika kwapamwamba komanso magwiridwe antchito oletsa kusokoneza.Ili ndi machitidwe asanu ndi limodzi odziyimira pawokha odziyimira pawokha, omwe amatha kuzindikira pulogalamu ya kutentha kwa masitepe 16, zomwe zimapangitsa zida kukhala zokhoza kusanthula zitsanzo.Ili ndi makina otsegulira khomo lakumbuyo kwa uvuni, yomwe imathandizira kuwongolera kutentha pang'ono ndikuwonjezera liwiro lokwera / kutsitsa.
●Chidacho chikhoza kukhala ndi zida zapamwamba zamagetsi zamagetsi (EFC) ndi zowongolera zamagetsi (EPC) kuti zizindikire kuwongolera kwa digito, zomwe zitha kusintha kwambiri kubweza kwa zotsatira zabwino komanso kuchuluka.
●Pulogalamu yodzipangira nthawi yodzipangira yokha imatha kumaliza kusanthula kwapaintaneti kwa zitsanzo zamagesi (zimafunika magawo a jakisoni wapaintaneti).
●Makina ogwiritsira ntchito kiyibodi yonse yowongolera ma microcomputer ndi osavuta komanso osavuta kugwiritsa ntchito;ndipo ukadaulo wodzizindikiritsa wodziwikiratu wa detector wapangidwa.Ndi kuzindikira zolakwika ndi kutetezedwa kwa data kuzimitsa, magawo amatha kuloweza pamtima.
●Chidacho chapanga phokoso lochepa, chigawo chapamwamba cha 24-bit AD chokhala ndi malo osungiramo maziko ndi kuchotsa koyambira.
●Sonkhanitsani ma chromatographic sign and processing data, oyenera WinXP, Win2000, Windows7 ndi machitidwe ena opangira.Deta yachitsanzo imawerengedwa kuchokera kumafayilo a CDF omwe amakwaniritsa miyezo ya A/A (American Analytical Society), kotero angagwiritsidwe ntchito ndi Agilent, Waters ndi malo ena ogwirira ntchito a chromatography.
●Dongosolo la Chromatographic lomwe lili ndi ufulu wodziyimira pawokha wazinthu zanzeru, zokhala ndi mawonekedwe okhazikika a MODBUS/TCP, zitha kulumikizidwa mosavuta ndi DCS.
●Chidacho chitha kulumikizidwa ndi sampler yamagalimoto opangidwa ndi opanga ambiri apakhomo ndi akunja;monga Shimadzu AOC-20i, kampani ya HTA ya HT yamadzimadzi othamanga kwambiri, oyesa gasi.
Kuzindikira mipweya | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 mpweya),O2(posankha), N2 (posankha) |
Display | 192 * 64 madontho masanjidwewo LCD |
Malo owongolera kutentha | 6 njira |
Kutentha kosiyanasiyana | kutentha kwa chipinda +5℃~400℃, , 1℃, kulondola:±0.1℃ |
Kukonzekera kwadongosolo | 16 masitepe |
Kukwera kwa pulogalamu | 0.1~40℃/min |
Kuwongolera gasi | makina owongolera valavu, njira yoyendetsera kuthamanga kwamagetsi mwakufuna |
Zochitika zakunja | 4 njira |
Mtundu wa jekeseni | odzaza ndime, capillary, njira zisanu ndi chimodzi vavu jekeseni mpweya, basi headspace jakisoni, etc. |
Chiwerengero cha zowunikira | 4pcs;FID, TCD, ECD, FPD (ngati mukufuna) |
Yambani jekeseni | manual, automatic optional |
Kulankhulana mawonekedwe | Efaneti: IEEE802.3 |
Zofufuza za Detector | |
Chowunikira chamoto cha haidrojeni chamoto (FID) | |
Malire ozindikira | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Phokoso loyambira | ≤ 5 × 10-14A |
Baseline drift | ≤ 1 × 10-13A / 30min |
Linear range | ≥106 |
Thermal Conductivity Detector (TCD) | |
Kumverera | S≥2500mV•ml/mg (benzene/toluene) (yokulitsidwa 1, 2, 4, 8 nthawi ngati mwasankha) |
Phokoso loyambira | ≤20μV |
Baseline drift | ≤30μV/30min |
Linear range | ≥104 |
Electronic Capture detector (ECD) kusankha | |
Malire ozindikira | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
Phokoso loyambira | ≤0.03mV |
Baseline drift | ≤0.2mV/30min |
Linear range | 103 |
Gwero la radioactive | 63 Ndi |
Flame Photometric Detector (FPD) kusankha | |
Malire ozindikira | (S) ≤ 5×10-11g/s, (P) ≤ 1×10-12g/s;methyl parathion / mtheradi ethanol) |
Phokoso loyambira | ≤ 3 × 10-13A |
Baseline drift | ≤ 2 × 10-12A / 30min |
Linear range | Fkapena sulfure ≥ 102, chifukwa phosphorous ≥ 103 |
Gasi Chromatograph Main Unit | 1 seti |
Jenereta ya haidrojeni | 1 seti |
Jenereta ya mpweya | 1 seti |
Multifunction Shaker | 1 seti |
Standard Pressure Reducing Valve | 1 seti |
Nayitrogeni Kuchepetsa Vavu | 1 seti |
Nitrogen Cylinder | 1 botolo |
Gasi wokhazikika | 1 botolo |
Njira ya gasi M8X1Φ3.2 | 10 ma PC |
Kuphatikizika kwa valve yochepetsera kuthamanga | 5 pcs |
Nati ya capillary Φ0.8 | 4 pcs |
Mzere wa mtedza Φ4.2 ndi Φ3.2 | Aliyense 5 pcs |
Chitoliro chamkati cha chitsulo chosapanga dzimbiri Φ2 | 10 ma PC |
Njira yosindikizira gasi | 50 ma PC |
Capillary sampler evaporative pad | 50 ma PC |
Capillary graphite pad Φ0.8 | 20 ma PC |
Padi ya graphite Φ4.2 ndi Φ3.2 | Aliyense 10 ma PC |
Fuse | 4 pcs |
Chithunzi cha M3X5 | 6 pcs |
Chitoliro cha gasi PE Φ3 | 20 m |
1 ml jekeseni wa pulasitiki | 5 pcs |
100 ml ya jakisoni | 5 pcs |
Singano | 10 ma PC |
20ml galasi jekeseni | 5 pcs |
5ml galasi jekeseni | 5 pcs |
1 ml jekeseni wa galasi | 5 pcs |
Zambiri kopanira | 2 ma PC |
Vaseline 30 g | 2 ma PC |
Slotted screwdriver 50mm 70mm | Aliyense 1 pc |
Crosshead screwdriver 50mm 70mm | Aliyense 1 pc |
Mphindi 8-10 | 1 pc |
Mphindi 12-14 | 2 pc pa |
Zopangira mphuno zakuthwa | 1 pc |
Chingwe chapansi | 1 pc |
Chingwe cholumikizira | 1 pc |
Chingwe champhamvu | 1 pc |
Chipewa cha mphira | 20 pc |
Chikwama cha Aluminium zojambulazo | 2 ma PC |
Singano iwiri | 25 pcs |
Disk | 1 pc |
Chingwe cholumikizirana | 1 pc |
Malo a gasi | 1 pc |