GDCR3000 Digital Earth Resistance Tester
GDCR3000 Digital Earth Resistance Tester idapangidwa mwapadera ndikupangidwira kuyeza kumunda, kutengera ukadaulo waposachedwa wa digito ndi yaying'ono, njira ya 3-pole kapena 2-pole poyezera kukana kwa dziko, yokhala ndi ntchito yapadera yotsimikizira kukana waya, kuthekera kolimbana ndi kusokoneza. ndi kuthekera kosinthira ku chilengedwe, kuonetsetsa kulondola kwambiri, kukhazikika kwakukulu komanso kudalirika kwanthawi yayitali, yomwe imagwiritsidwa ntchito kwambiri mumagetsi, matelefoni, meteorology, malo opangira mafuta, zomangamanga, chitetezo cha mphezi, zida zamagetsi zamafakitale ndi zina zapadziko lapansi kukana. kuyeza.
Ntchito yoyezera | Mtundu | Kulondola | Kusamvana |
Kulimbana ndi dziko lapansi | 0.01Ω~20Ω pa | ±2%rdg ± 3dgt (Zothandizira zapadziko lapansi 100Ω ± 5%, mphamvu yapadziko lapansi<10V) | 0.01Ω |
0.1 Ω~200Ω pa | 0.1 Ω | ||
1 Ω pa~2000Ω | 1 Ω pa | ||
Voltage yapadziko lapansi | 0~600V AC | ± 1%rdg ±3dgt | 1V |
Ntchito | Muyeso wa kukana kwapadziko lapansi, kuyeza kwamagetsi mpaka pansi, kuyeza kwa mtengo wotsika |
Magetsi | DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS) |
Kuwala kwambuyo | Kuwala kowoneka bwino kwa buluu, koyenera kugwiritsidwa ntchito pamalo amdima. |
Mulingo woyezera | Muyezo wolondola wa mizati 3, muyeso wosavuta wa 2-pole |
Njira Yoyezera | Earth ground resistance: adavotera njira yosinthira-pole, muyeso wapano20ma Max. Voltage to ground: kukonzanso mtengo kwapakati |
Data Mode | Mtengo wapakati, wopambana, wocheperako |
Waya Resistance Verification | Pewani cholakwika chobwera chifukwa cha mawaya oyesera omwe sanalowetsedwe m'njira yoyesera kapena chifukwa chosalumikizana bwino kapena chifukwa chakusintha kapena kutalikitsa mawaya oyesera, kupangitsa kuti ikhale yolondola poyezera kulimba kwa nthaka. |
Mawonekedwe Mode | Chiwonetsero cha 4-digital chapamwamba kwambiri cha LCD, chowunikira chakumbuyo chabuluu |
Chizindikiro choyezera | Pakuyezera, chizindikiro cha kuwala kwa LED, chiwonetsero cha LCD chowerengera pansi |
LCD Dimension | 128mm × 75mm;Onetsani gawo:124 × 67 mm |
Dimension | L×W×H: 215mm×190mm×95mm |
Mawaya Oyesera | Mawaya atatu: iliyonse ya Red 20m, Yellow 10m, ndi Green 5m |
Waya Woyesera Wosavuta | Mawaya awiri: iliyonse ya Red 1.6m ndi Green 1.6m |
Ndodo yothandizira nthaka | 2 ma PC: Φ10mm×150mm |
Mulingo Woyezera | Voltage pansi: pafupifupi 3 nthawi / sekondi;kukana kwapadziko lapansi: pafupifupi 5 masekondi / nthawi |
Kuyeza Nthawi | Nthawi zopitilira 5000 (Kuyeza 10Ω kwa nthawi imodzi pa 20Ω ndi kuima kaye30s) |
Circuit Voltage | Kuyeza magetsi mpaka pansi: kuyeza pansi pa AC 600V |
USBChiyankhulo | TenganiUSBmawonekedwe, kuyang'anira mapulogalamu, deta yosungirako ikhoza kuikidwa pa kompyuta, kusungidwa kapena kusindikizidwa. |
Kulumikizana Waya | Chidutswa chimodzi chaUSBwaya wolumikizana, wokhala ndi kutalika kwa 1.5m |
Kusungirako Data | 400 seti, chiwonetsero chazithunzi "FULL" chosonyeza kuti kusungirako kwadzaza |
Data Hold | Ntchito yosunga data: "HOLD" chiwonetsero chazithunzi |
Data Read | Ntchito yowerengera deta: "WERENGANI" chiwonetsero chazithunzi |
Chiwonetsero Chosefukira | Kupitilira muyeso wazosefukira: "O" chiwonetsero chazithunzi |
Ntchito Alamu | Muyeso woyezera ukadutsa mtengo wa ma alarm, pali chidziwitso cha "Toot-toot-toot". |
Mphamvu ya Battery | Mphamvu ya batri ikatsika mpaka pafupifupi 7.8V, chizindikiro chotsika cha batire chidzawonetsedwa, kukumbutsakulipira. |
Kugwiritsa Ntchito Mphamvu | Kuwala kwambuyo: 25mA Max |
Standby: 25mA Max (Backlight yatsekedwa) | |
Kuyeza:200mA Max (Backlight yatsekedwa) | |
Kulemera | Woyesa:1325g (kuphatikiza batri) |
Mawaya Oyesera:847g pa(kuphatikiza mawaya oyesera) | |
Mtundu Wothandizira:468g pa(2 ma PCS) | |
Chikwama cha mita:915g pa | |
Kutentha kwa Ntchito & Chinyezi | -10 ℃~40℃;pansi pa 80% rh |
Kutentha kosungira & chinyezi | -20 ℃~60℃;pansi pa 70% rh |
Chitetezo Chowonjezera | Kuyeza kukana kwa nthaka: pakati pa malo aliwonse a EP, EC, AC 280V/3 masekondi |
Kukana kwa Insulation | Kupitilira 10MΩ (pakati pa dera ndi mpanda ndi 500V) |
Kulimbana ndi Voltage | AC 3700V/rms (Pakati pa dera ndi mpanda) |
Electromagnetic Features | Wireless frequency electromagnetic field |
Mtundu wa Chitetezo | IEC61010-1,IEC1010-2-31,IEC61557-1,5,IEC60529(IP54),Kuipitsa ndi zina 2,CATⅢ 300V |