GDHG-108A CT/PT Analyzer
GDHG-108A CT/PT Tester imathandizira njira yoyesera yamagetsi kuyesa ma bushings CTs omwe adayikidwa pa thiransifoma kapena mkati mwa zida zosinthira, zoyenera ku labotale komanso kuzindikira komwe kuli pamalopo.
Itha kuchitidwa mosavuta komanso mosavuta mawonekedwe amagetsi apano, chiŵerengero cha thiransifoma, chiŵerengero ndi cholakwika cha gawo, zinthu zoyesa pa CT/PT.
●Kugwiritsa ntchito njira yodziwira ma voltage kuyeza CT ndi PT.
●Kukwaniritsa zofunikira za GB1207, GB1208, GB168-47 (IEC60044-1.6) ndi miyezo ina.
●Palibe zida zothandizira zakunja, makina amodzi amatha kumaliza zinthu zonse zoyeserera.
●Ndi chosindikizira chachikulu chothamanga kwambiri: sindikizani zotsatira zoyeserera munthawi yeniyeni.
●Pogwiritsa ntchito wolamulira wanzeru, ntchito ndi yosavuta.
●5 inchi LCD chiwonetsero chazithunzi.
●Kupatsidwa CT/PT (chisangalalo) phindu la bondo.
●Onetsani Auto 5% ndi 10% zolakwika pamapindikira.
●Sungani data yamagulu 3000, sidzatayika pambuyo pozimitsa.
●Ndi doko la USB.Deta ikhoza kusungidwa mu disk ya USB ndikuwerengedwa ndi PC (fayilo ya WORD).
●Kulemera kopepuka, kosakwana 22kg, koyenera kuyesa pamasamba.
Ntchito zazikulu
CT(kuzindikira voteji) | PT |
•Vchikhalidwe chamakonokupindika (makhalidwe osangalatsa) | •Vchikhalidwe chamakonokupindika (makhalidwe osangalatsa) |
•Auto kuwerengera mtengo wa mawondo | •Auto kuwerengera mtengo wa mawondo |
•Onetsani Auto 5% ndi 10% zolakwika pamapindikira | •Amatembenuza muyeso wa chiŵerengero |
•Amatembenuza muyeso wa chiŵerengero | •Kutsimikiza kwa polarity |
•Kutsimikiza kwa polarity | •AC Hipot Test |
•AC Hipot Test | •Demagnetizationn chuma chapakati |
•Demagnetizationn chuma chapakati | • Kuchuluka kwa Voltage kumatha kusinthidwa (1.2-2.5times) mu mayeso a PT VA |
• Muyezo wolondola wa malire (ALF). |
Main magawo
Kanthu | Parameter | |
Magetsi | AC220V±10%, 50Hz pa | |
Zotulutsa | 0-1000Vrms(20Ansonga) | |
Kulondola kwa kuyeza kosangalatsa | ≤ 0.4% ya kuwerenga + 0.6% yamtundu | |
CT amatembenuza muyeso wa chiŵerengero | Range | ≤3000A/1A(15000A/5A) |
Akulondola | ±1.0% | |
PT amatembenuza muyeso wa chiŵerengero | Range | ≤500KV |
Akulondola | ±1.0% | |
Malo ogwirira ntchito | Kutentha:-10 ℃ ~ 40 ℃, chinyezi:≤90%, Altitude:≤1000m | |
Dimension & Weight | Dimension:440mm × 360mm × 340mmKulemera kwake:≤22Kg |
CT/PT Tester | 1 chidutswa |
Mayeso Wotsogolera | 1 seti |
Chingwe cha Earth | 1 chidutswa |
Chingwe champhamvu | 1 chidutswa |
2 A fuse | 2 ma PC |
Wogwiritsa ntchito | 1 kopi |
Lipoti la mayeso a fakitale | 1 kopi |