GDJB-6000M Smart Substation Relay Protection Test System
GDJB-6000M Smart Substation Relay Protection Test System ndi m'badwo watsopano wa oyesa anzeru achitetezo opangidwa molingana ndi "Smart Substation Relay Protection Technical Specifications" ndi "Smart Substation Technical Guidelines".Sizingangozindikira kuyesa kwathunthu kwa chipangizo chachitetezo cha digito (IEC61850, smart digital station), komanso kuchita mayeso athunthu pazida zodzitchinjiriza (zovomerezeka).
GDJB-6000M ndi chinthu chatsopano chonyamulika chomwe chimapangidwa mwachisawawa pogwiritsa ntchito matekinoloje monga makina ogwiritsira ntchito nthawi yeniyeni, mapurosesa ophatikizika kwambiri, ndi zida zazikulu zomveka, zophatikizidwa ndi mikhalidwe yamunda wamagetsi ndi zochitika zambiri za ogwiritsa ntchito mphamvu.Imagwiritsidwa ntchito kwambiri pamafakitale amagetsi, malo ocheperako, opanga zida, mabizinesi ndi mabungwe, komanso mabungwe ena ofufuza omwe amafunikira kuyesa kapena kuyang'anira chitetezo cha relay.
GDJB-6000M imatengera chiwembu choyang'anira uinjiniya kuti ayendetse mayeso;kasamalidwe ka projekiti amatengera mitundu itatu ya zida zodzitetezera, mtundu wachitetezo, ndi malo oyeserera kuti athe kuyang'anira mayeso.Mapangidwe ake ndi omveka bwino;Imathandizira kutulutsa kwa analogi, ndipo nthawi imodzi imatha kutulutsa kuchuluka kwa analogi ndikutumiza & kulandira mauthenga a GOOSE;Amapereka njira zingapo zosinthira mauthenga a SV ndi GOOSE, kuphatikiza zoikamo pamanja, kuzindikira maukonde, ndi kutumiza mafayilo a SCL;Mauthenga a digito owoneka bwino ali ndi kasinthidwe kosinthika kwambiri kwa transceiver, yomwe imatha kutumiza mauthenga angapo a SV ndi GOOSE ndi 1 optical port, ndipo mauthenga omwewo a SV ndi GOOSE amatha kutumizidwa kudzera pamadoko angapo optical.
DL/T 860 Series Standard "Substation Communication Network ndi System"
DL/T 624-2010 "Technical Conditions for Relay Protection Microcomputer Based Test Equipment"
GBT 7261-2008 "Basic Test Method for Relay Protection and Safety Automatic Devices"
TS EN 60255-24: 2001 Zolumikizira zamagetsi - Gawo 24: Mawonekedwe wamba pakusinthana kwa data kwakanthawi (COMTRADE) pamakina amagetsi"
●Smart Test Module
Kusintha kwa template mwanzeru kumathandizidwa.Zinthu zoyeserera zitha kuwonjezeredwa mwachisawawa panthawi yoyeserera ndikusungidwa ngati mafayilo oyeserera obwereza kuti apititse patsogolo kuyesako komaliza poyang'anira ndi kuchotsa.Ntchito zamphamvu zamapulogalamu.Nthawi yeniyeni yowonetsera mawonekedwe, max.Peak ndi malo.Pulogalamuyi imatha kuyang'ana ndikuwunika mawonekedwe ena agawo.Mawindo akhoza kulowetsedwa mkati ndi kunja.Deta ya gawo limodzi imatha kuyesedwa mowoneka bwino ndipo mawonekedwe amtundu wa discharge waveform akhoza kuwunikidwa.
●Kuyesa kwachangu
Ndi chitetezo cha pa malo ndi chitetezo cha digito ntchito yoyesera yodziwikiratu, zinthu zonse zoyesera za chipangizo chimodzi chotetezera zingathe kutsirizidwa ndi fungulo limodzi.Deta yoyesera ndi mawonekedwe otulutsa mafunde osakhalitsa amatha kupulumutsidwa okha kapena pamanja.
●Kutulutsa kwa digito / analogi
Itha kuyesa zida zophatikizira, chitetezo, kuyeza ndi kuwongolera zida, ndi ma terminals anzeru a malo a digito, komanso kuyesa zida monga chitetezo cha analogi ndi thiransifoma.
●Kutulutsa munthawi yomweyo kwa analogi ndi kuchuluka kwa digito
Imathandizira kutulutsa kwa analogi munthawi imodzi ndi kutumiza ndi kulandira uthenga wa GOOSE.
● Angapo sikani modes
Imathandiza matalikidwe, gawo, pafupipafupi, impedance, vekitala, zinayendera, ndi mphamvu ikuchitika ndi mayeso Buku kapena basi, komanso amathandiza basi kusintha mayeso malinga ndi njira gradation, kuzembera ndi kaphatikizidwe.
● Chitetezo ndi alamu
Pokhala ndi chitetezo chowonjezereka komanso chamakono, gwero lamakono lili ndi chitetezo chotseguka ndi ntchito ya alamu, ndipo gwero lamagetsi limakhala ndi ntchito yowonjezereka komanso yotetezera nthawi yochepa.
● Chiwonetsero chazithunzi cha Virtual terminal
Thandizani ntchito yowonetsera mawonedwe a terminal, kusuntha kwa deta kumamveka bwino.
●Tumizani ndi kulandira mauthenga nthawi yomweyo
Thandizani IEC61850-9-1, IEC61850-9-2 ndi GOOSE kuwala kwa uthenga wa digito.Chizindikiro cha GOOSE chitha kutumizidwa ndikulandiridwa paokha, ndipo imathanso kutumiza ndikulandila ndi mawonekedwe a Ethernet opangidwa ndi IEC 61850-9-2.
● FT3/Yowonjezera FT3
Kuthandizira FT3, kuwonjezera FT3 ndi DL/T 282 kutulutsa uthenga, ndikuthandizira 2M/4M/6M/8M/10M baud mlingo wa UART encoding ndi 5M/10M/20M Manchester encoding.
● Kuyesedwa kwachilendo
Ndi ntchito yachilendo ya uthenga wa analogi, imatha kutsanzira zachilendo, kutumiza ma frequency jitter, kuchedwa kusokonezeka, kutayika kwa paketi, kutuluka, kulumpha kwa serial, kukonza, kusintha kwamtundu ndi mayeso ena.
● Kusewera kolakwika
Imathandizira kuyerekezera zolakwika ndi kusewerera kwamtundu wa COMTRADE.
● Ntchito ya MMS
Ndi ntchito yowerenga ndi kulemba ya MMS, mutha kuwerenga ndi kulemba zoikamo zanzeru za IED ndi zina zambiri zosintha.
● Kuyanjanitsa nthawi ndi kupereka nthawi
Ndi synchronous trigger function, kuthandizira kulumikiza kwachindunji kwa GPS/BD mlongoti pa nthawi yolumikizana, imathandiziranso IRIG-B, PPS ndi PTP 1588 mawonekedwe anthawi ndipo imatha kuthandizira kutulutsa kwakunja kwa IRIG-B, PPS ndi PTP 1588 yopereka chizindikiro.
● Kulumikizana kolimba kwa binary ndikutulutsa kwa binary
Kuchulukitsitsa kolowera kumagwira ntchito komanso kungokhala chete kulumikizidwa, ndipo mtundu wolowera ndi magetsi olowera zimazindikirika.Makanema ali olekanitsidwa wina ndi mzake, ndipo kulumikizana kwa polarity ndi alamu mwachangu.
●Kulandila ndi kusanthula uthenga
Ndi ntchito yolandila ndi kusanthula, uthenga womwe walandilidwa utha kutsegulidwa ndi ZHNPA kuti aunike kapena kutumiza kunja.
●Single fiber mode
Doko la kuwala limathandizira kutumiza kwa fiber imodzi ndi kulandila kwa fiber imodzi ndikuthandizira kuyesa kwamagetsi.
●Analogi yaying'ono chizindikiro
Ili ndi mawonekedwe ang'onoang'ono a analogi, kuthandizira 12 njira ya analogi yaying'ono, imatha kuyeza -7V ~ 7V AC voteji, kuthandizira 12 njira yaing'ono ya analogi, ndipo imatha kutulutsa -7V ~ 7V AC voteji.
●Kugwira ntchito
Chokhala ndi chiwonetsero cha 10.4 inchi chokhala ndi mawonekedwe apamwamba chomwe chimathandizira kugwira ntchito.
●Kulumikiza opanda zingwe
Perekani ntchito yoyeserera yakutali, yokhala ndi gawo la WiFi, yosavuta kugwiritsa ntchito.
Kutulutsa kwamagetsi kwa AC | Mtundu: 6 × 120 V, 120V / 60VA panjira Kulondola: ± 10mV pa 0.2 ~ 2V;± 0.2% pa 2V ~ 120V Kusintha: 1mV |
Kutulutsa kwa AC panopa | Mtundu: 6 × 30A, 30A / 150VA njira iliyonse Kulondola: ± 10mA kwa 0 ~ 500mA;± 0.2% kwa 500mA ~ 30A Kusamvana: 1mA |
Gawo lotulutsa | Kutalika: 0 ~ 360 ° Kulondola: ± 0.1 ° Kusamvana: 0.1 ° |
Linanena bungwe pafupipafupi | Mtundu: 0 ~ 1000Hz Kulondola:<±0.001Hz (0~65Hz) <±0.01Hz(65~450Hz) <±0.02Hz (450~1000Hz) Kusintha: 0.001 Hz |
Mphamvu yamagetsi yamagetsi ya DC | Mtundu: 6 njira, njira iliyonse 0 ~ 130V / 60VA Kulondola: 0.2% |
Zotsatira zaposachedwa za DC | Mtundu: 6 njira, njira iliyonse 0 ~ 20A / 100VA Kulondola: 0.2% |
Kulumikizana kwa IEC 61850 | Chiwerengero cha madoko: 6 awiriawiri ndi 100M adaptive;2 pairs ndi 100/1000M adaptive Mtundu wa Chiyankhulo: LC Kutalika: 1310nm |
Kulumikizana kwa IEC 60044 | Chiwerengero cha madoko: 6 ma doko otumiza, 2 amalandila madoko Mtundu wa Chiyankhulo: ST Kutalika: 850nm |
Kulunzanitsa mawonekedwe | Kuchuluka: 1 * GPS / BD ANT;2 * IRIG-B/PPS chizindikiro cha kuwala-1 ya nthawi, 1 yopereka nthawi;2 mapeyala * IRIG-B/PPS zizindikiro zamagetsi-1 peyala ya nthawi, 1 peyala ya nthawi yopatsa;1 awiri * IEEE 1588; Mtundu wa mawonekedwe: GPS / BD ANT, IRIG-B / PPS chizindikiro cha kuwala;IRIG-B / PPS chizindikiro chamagetsi;Mtengo wa 1588 |
Kuyeza nthawi | Kutalika: 10ms ~ 9999.999s Kulondola: 1ms |
Sinthani zolowetsa | Kuchuluka: 8 pairs Kusokoneza Mphamvu: DC250V/0.5A |
Sinthani zotulutsa | Kuchuluka: 6 awiriawiri, omwe 2 awiriawiri ndi otsegula mwachangu |
Kulumikiza opanda zingwe | Mtundu wa Chiyankhulo: WIFI |
Kulumikizana kwa mawaya (mawonekedwe olumikizirana a Ethernet) | Chiwerengero cha madoko: l 2 Mtundu wa mawonekedwe: 100 megabytes LAN port, RJ45 |
Magetsi | Voltage: AC/DC 220V, kupatuka kovomerezeka: -20% ~ 15% Fpafupipafupi: 47-65 Hz |
Chizindikiro chaching'ono cha analogi | Chiwerengero cha njira: 12 njira; Mtundu wa Chiyankhulo: Pulagi ya Aviation, AC Voltage |
Analogi yaying'ono yotulutsa chizindikiro | Chiwerengero cha njira: 12 njira; Mtundu wa Chiyankhulo: Pulagi ya Aviation, AC Voltage |
USB mawonekedwe | Kuchuluka: 2 |
Malo ogwirira ntchito | Kutentha kogwira ntchito: -20°C ~ 70°C Chinyezi: ≤95%, palibe condensation |
Ena | Kulemera kwake: 15kg Kukula: 360×480×190(mm) Mawonekedwe a pa intaneti: RJ45 Chiwonetsero: 10.4 inchizenera logwira1024 * 768 mtundu weniweni wa LCD chiwonetsero |