GDJB-802 Three Phase Secondary Current Relay Test Set
GDJB-802 3 Phase Secondary Current Injection Relay Protection Chipangizo chimagwira ntchito yofunika kwambiri pakugwiritsa ntchito mphamvu zamagetsi modalirika komanso motetezeka.Imatha kuweruza mopitilira apo, kuchuluka kwamagetsi, kuchulukira, kufupikitsa, kutentha kwambiri, data yosadziwika bwino komanso machenjezo oti agwiritse ntchito molakwika.Kuphatikiza pa kutsimikizira kwa ma relay osiyanasiyana (monga apano, voteji, nthawi yosinthira, kuwongolera mphamvu, kusokoneza, kusiyanitsa, kutsika pang'ono, kulunzanitsa, ma frequency, DC, apakatikati, nthawi, ndi zina) ndi chitetezo cha microcomputer, imathanso kutsanzira imodzi. -gawo mpaka magawo atatu osakhalitsa, okhazikika, ndi zolakwika zosinthika zimayesedwa pa seti yonse.Imathanso kumaliza ntchito zosiyanasiyana zazikulu komanso zovuta zoyeserera ndi makina apamwamba kwambiri, imatha kuyesa zokha ndikusanthula makonda osiyanasiyana achitetezo, zoyeserera zosungira munthawi yeniyeni, zowonetsa ma vector, ndikusindikiza malipoti pa intaneti.
Imatha kudziyesa paokha poyesa kuyesa kwa chipangizo m'magawo aukadaulo monga chitetezo cha microcomputer, chitetezo cholumikizirana, kusangalatsa, kuyeza, kujambula zolakwika, ndi zina zambiri. Amagwiritsidwa ntchito kwambiri pofufuza zasayansi, kupanga ndi malo oyesera magetsi pamagetsi amagetsi, petrochemical, zitsulo, njanji, ndege. , zankhondo ndi mafakitale ena.
●Standard 4-phase voltage ndi 3-phase current output, zomwe zimapangitsa kuti zikhale zosavuta kuchita ndikuphatikizana ndi zotuluka zosiyanasiyana pamitundu yosiyanasiyana ya mayeso achitetezo.Gawo lililonse lamagetsi limatha kutulutsa 120V, gawo limodzi lamakono max.Zotulutsa 40A (10s), zofananira zitatu zapano zitha kutulutsa 120A.Gawo lachinayi voteji Ux ndi mawu amagetsi amitundu yambiri.Itha kukhazikitsidwa ngati mitundu inayi ya 3U0 kapena voteji yolumikizira, kapena kutulutsa pamtengo uliwonse wamagetsi.
●Kompyuta imodzi ndiyosavuta kugwiritsa ntchito.Kompyuta imodzi imayendetsedwa ndi mbewa yosinthasintha komanso yosavuta yozungulira kudzera pa sikirini yayikulu ya LCD.Zonsezi zikuwonetsedwa mu Chingerezi.Ikhoza kumaliza ntchito zambiri zoyesa ndi kutsimikizira m'munda.Itha kuyang'ana mitundu yonse yachitetezo chozikidwa pa microprocessor ndikutsanzira mitundu yonse ya zovuta nthawi yomweyo, zokhazikika komanso zosinthika kuti ziyese mayeso ambiri.Itha kugwiritsidwa ntchito mukangoyambitsa, ndipo ndiyosavuta komanso yachangu kugwira ntchito.
●Kuphatikizika kwapawiri, kulumikiza kompyuta kuti igwiritse ntchito pulogalamu yathunthu yachingerezi papulatifomu ya Windows, imatha kugwira ntchito zazikuluzikulu, zovuta komanso zodziwikiratu, zimatha kuyesa ndikusanthula zoikamo zosiyanasiyana zachitetezo, zimatha kusunga zoyeserera zenizeni. nthawi, chiwonetsero cha vekitala, kujambula mawonekedwe a zolakwika, malipoti osindikizira pa intaneti ndi zina zotero.
●Pulogalamuyi ili ndi ntchito zamphamvu ndipo imatha kumaliza ntchito zingapo zazikulu komanso zovuta zotsimikizira ndi makina apamwamba kwambiri, monga kuyesa kwa magawo atatu, kusinthana mwachangu kwamagetsi othandizira, kuyesa kosintha koyimirira, kutsekanso kolumikizana kwachitetezo cha mzere, etc. Itha kuyesa ndikusanthula makonda osiyanasiyana achitetezo, kusewerera zolakwika, kuyesa kuyesa mu nthawi yeniyeni, kuwonetsa mamapu a vector, ndikulumikizidwa ndi lipoti la kompyuta ndi kusindikiza, ndi zina zambiri.
●Kusintha kuchuluka kwa omwe mumalumikizana nawo kumalemeretsa, ma tchanelo a 8 olowetsamo ndi ma 2 awiriawiri otulutsa opanda kanthu.Maulalo olowera amagwirizana ndi olumikizana opanda kanthu ndi ma 0-250V omwe angathe kulumikizidwa, omwe amatha kudziwika okha komanso mwanzeru.Othandizira ndi linanena bungwe kulankhula akhoza anawonjezera malinga ndi zosowa wosuta a.
●Chiwonetsero chachikulu cha LCD chimagwiritsa ntchito 320 * 240 dot matrix chachikulu chophimba chokhala ndi mawonekedwe a LCD.Njira zonse zogwirira ntchito zimayikidwa pazenera.Mawonekedwe ogwirira ntchito ndi zotsatira zoyesa amawonetsedwa m'Chingerezi, ndipo mawonekedwe ake ndi omveka komanso omveka bwino.
●Kudzitchinjiriza, kumatengera mawonekedwe otenthetsera kutentha, ndipo kumakhala ndi njira zodalirika komanso zodzitchinjiriza, kuyambika kofewa kwamagetsi, komanso kudzizindikiritsa nokha ndi kutseka ntchito zina.
●Ili ndi mphamvu yodziyimira payokha yodzipatulira ya DC, yokhala ndi 110V imodzi ndi 220V yodzipatulira yosinthika yamagetsi a DC.
●Kuchita kwamtengo wapamwamba ndi chinthu chopangidwa ndi akatswiri ophatikizana, chomwe chimapanga zopambana zasayansi ndiukadaulo zamaluso ambiri.Ili ndi magwiridwe antchito a tester yayikulu komanso mtengo wa tester yaying'ono, ndipo imakhala ndi chiŵerengero chapamwamba chamtengo wapatali.
Kutulutsa kwa AC | Gawo laposachedwa (mtengo wogwira ntchito) | 0-40A |
Phase current max.okutulutsa mphamvu | 420VA | |
Kuchulukira kofanana kwapano (mtengo wogwira ntchito) | 0-120A | |
Mphamvu zofananira kwambiri | 900VA | |
Mtengo wovomerezeka wanthawi yayitali wagawo lapano (mtengo wogwira ntchito) | 10A | |
Nthawi yovomerezeka yogwira ntchito pakali pano | 10s | |
Frequency range (mafunde oyambira) | 20-1000Hz pa | |
Harmonic wave nthawi | 1-20 nthawi | |
Kulondola | 0.2% | |
Mphamvu yamagetsi ya AC | Phase voltage output (mtengo wogwira ntchito) | 0 ~ 120V |
Line voltage output (mtengo wogwira ntchito) | 0 ~ 240V | |
Phase voltage/Line voltage output power | 80VA/100VA | |
Frequency range (mafunde oyambira) | 20-1000Hz pa | |
Harmonic wave nthawi | 1-20 nthawi | |
Kulondola | 0.5% | |
Mphamvu yamagetsi ya DC | Phase voltage output range | 0 ~ ± 160V |
Line voltage output range | 0 ~ ± 320V | |
Phase voltage/Line voltage output power | 70VA/140VA | |
Kulondola | 0.2% | |
Zotsatira zaposachedwa za DC | Zotulutsa | 0-± 10A / gawo, 0-±30A / parallel |
Maximum linanena bungwe katundu voteji | 20 V | |
Kulondola | 0.2% | |
Kulowetsa kwa binary (7channel) | Kulumikizana kosagwira ntchito | 1 ~ 20mA, 24V (DC) |
Kukhudzana ndi magetsi | "0":0- +6V; "1": +11 V- +250V | |
Kutulutsa kwa binary (2pairs) | DC 220V/0.2A AC 220V/0.5A | |
Kuyeza nthawi | Muyezo osiyanasiyana: 0.1ms-9999s kulondola 0.1ms | |
Size | 400× 300 × 180mm³ | |
Kulemera | 22kg | |
Perekani mphamvu | AC 220V±10%,50/60Hz pa | |
Kutentha kwa chilengedwe | -10 ℃~+ 50℃ |
GDJB-802 Host & Portable box | 1 seti |
Chingwe champhamvu | 1 chidutswa |
Chingwe chamakono (4-core, red, yellow, green, black) | 1 chidutswa |
Chingwe chamagetsi (4-core, red, yellow, green, black) | 1 chidutswa |
Chingwe choyesera (1 iliyonse yofiira, yachikasu, yobiriwira, yakuda, yabuluu, yoyera) | 6 zidutswa |
Chingwe choyesera (2 iliyonse yofiira, yachikasu, yobiriwira, yakuda) | 8zigawo |
2A, 10A Fuse (mapcs 4 aliwonse) | 8zigawo |
Chithunzi cha RS232 | 1 chidutswa |
U disk; | 1 chidutswa |
Zithunzi zazikulu za alligator (1 iliyonse yofiira, yachikasu, yobiriwira, yakuda) | 4 zidutswa |
Ting'onoting'ono ta alligator (3 iliyonse yofiira, yakuda, yachikasu, yobiriwira) | 12 zidutswa |
Pini yoyesera (2 iliyonse yofiira, yakuda, yachikasu, yobiriwira) | 8zigawo |
Ikani (2 iliyonse yofiira, yachikasu, yobiriwira, yakuda) | 8zigawo |
Kalozera wa ogwiritsa ntchito | 1 kopi |
Mndandanda wazolongedza | 1 kopi |
Lipoti la mayeso a fakitale | 1 kopi |
Khadi ya chitsimikizo | 1 kopi |