GDJD-3A SF6 Gas Density Relay Calibrator
GDJD-3A SF6 gas Density Relay Calibrator ndi calibrator yokha, yomwe imagwiritsa ntchito microprocessor yophatikizidwa kuti ipititse patsogolo ntchito yamitundu yonse ya SF6 gas density relay.Ndi chipangizo chonyamulika chomwe chingapangitse kutembenuka kokhazikika kwa SF6 kuthamanga kwa mpweya pa kutentha kulikonse.Chipangizochi chimagwiritsidwa ntchito kwambiri popanga zinthu zamafuta a SF6, kukonza ndi kuyang'anira machitidwe amagetsi.
●Sanizanitu kachulukidwe relay ndi kupima kuthamanga.
●Kapangidwe kakang'ono, kakulidwe kakang'ono, ndi kulemera kopepuka, kosavuta kunyamula.
●Mtundu wa LCD chophimba, Windows menyu.
●Magetsi ali ndi ntchito ya UPS, yoyenera kugwira ntchito kumunda.
●Ndi mini-printer, kusindikiza zotsatira zoyesa mwachindunji.
●Malo abwino osindikizira, musawononge mpweya wa SF6 pakuwongolera.
●Malekezero awiri a chitoliro cholumikizira ali ndi valavu yoyang'ana mofulumira, ntchito yosavuta komanso kupewa madzi ndi mpweya kulowa mu chitoliro.Palibe chifukwa chochotseratu kachulukidwe kachulukidwe kawo kuti muwerenge molunjika.
●Pali automatic voltage protector ya sampling point.Ngati sample point clip ikusokonekera ndi 220V voltage, sizingawononge chipangizocho.
Yesani zokha kukakamiza pamene SF6 kachulukidwe gasi relay alarm kapena disasalarm pa kutentha kulikonse chilengedwe.Imathanso kuyisintha kukhala kukakamiza kokhazikika pa 20 ℃, kuti izindikire kusintha kwa ma alarm.
Yesani zokha kukakamiza pamene SF6 gas density relay interlock kapena relive interlock pa kutentha kulikonse.Imathanso kuyisintha kukhala kukakamizidwa kokhazikika pa 20 ℃, kuti izindikire kusinthasintha kwa magwiridwe antchito.
Ngati pali choyezera kuthamanga kapena kachulukidwe mita ya SF6 yoyesedwa kachulukidwe ka gasi relay, imatha kuyesa kulondola kwa geji yopimira kapena mita ya kachulukidwe.
Sinthani kuthamanga kwa mpweya wa SF6 kukhala kuthamanga kwapakati pa 20 ℃.
Sinthani kuthamanga kwapakati pa 20 ℃ kukhala kukakamiza pa kutentha kulikonse.
Khazikitsani miyeso ingapo ya kachulukidwe kamodzi.Zotsatira zake ndi mtengo wapakati.
Magetsi: Kugwiritsa ntchito AC/DC, batire yomangidwanso, AC 220V ± 10%, 50Hz
Kulondola: Kalasi 0.25
Sonyezani: 3.5inch woona mtundu LCD chophimba
Printer: Microprinter ya mtundu wa singano
Kuthamanga kwapakati: 0-1.0Mpa
Calibration kuthamanga osiyanasiyana: muyezo kuthamanga 0-0.9Mpa pa 20 ℃
Kutentha osiyanasiyana: -50 ℃--100 ℃
kukula: 258 * 240 * 88mm
Kulemera kwake: pafupifupi 2.5kg
Pressure resolution: 0.0001Mpa
Kusintha kwa kutentha: 0.1 ℃
Kusungirako mphamvu: 50-100pcs
Doko lolumikizana: USB2.0