GDJF-2007 Digital Partial Discharge Analyzer
GDJF-2007 Digital Partial Discharge Analyzer imagwiritsidwa ntchito kwambiri pozindikira kutulutsa kwapang'onopang'ono kwa zida zamagetsi apamwamba monga zosinthira mphamvu, chosinthira zida, HV circuit breaker, GIS, Zinc oxide surge arrester, chingwe chamagetsi.Ithanso kupanga mayeso amtundu ndikuyang'anira ntchito yotsekera.
Zimaphatikizapo gawo lalikulu, pulogalamu ya PD, chosinthira chapano, gawo lolowera, jenereta ya calibration pulse, adapter yolowera, amplifier ya mlongoti ndi chingwe cholumikizira etc.
●Chiwonetsero cha 12inch LCD, chopangidwa ndi kunyamula, cholimba komanso cholimba, chosavuta kugwiritsa ntchito.
●Mphamvu zotsutsana ndi kusokoneza, zolondola.Pogwiritsa ntchito ukadaulo wosefera wa digito, kusokoneza m'munda kumatha kuthetsedwa bwino, ndipo kuyeza kwapang'ono kutha kuchitika m'malo osokoneza kwambiri.
●Kupeza ma data panjira zambiri.Chophimba chimodzi chimatha kuwonetsa 2channels kapena 4channels waveform.
●Wamphamvu mapulogalamu ntchito.Ndi muyeso wa PD, kusanthula, PD mobwerezabwereza kutulutsa nthawi N kuyeza, kusanthula ndi kusokoneza kosagwirizana, kusokoneza kotsutsana ndi mphamvu.Kusankha kwaulere kwa ellipse, mzere wowongoka ndi mawonekedwe a sinusoidal.Yezerani ndi Kuwona kutulutsa kwamphamvu ndi zenera, ndi voteji yoyeserera ndi yapano, kutulutsa pang'ono kumatha kuyeza nthawi imodzi.Zonse zoyeserera za 2channel zitha kusungidwa munthawi yake.Mawonekedwe oyeserera amatha kupulumutsidwa, kuwonetsedwanso ndikuwunikidwa.Kuchuluka kwa tchanelo chilichonse kumatha kusinthidwa mokulira ndikusinthidwa bwino.Tekinoloje yotsegula mazenera a digito, kuti mupewe kusokoneza pakuyeza.Kutsegula zenera la gawo, zenera limodzi ndi zenera ziwiri zitha kusankhidwa.Zenera likhoza kutsegulidwa momasuka mkati mwa 360degree.
●Mogwirizana ndi IEC60270 muyezo.
●Mtundu wa mphamvu: 6pF-250μF
●Kumverera: 0.1pc
●Njira yoyezera: 2 kapena 4pcs njira zodziyimira
●Kulondola kwa zitsanzo: 12Bit
●Chiwerengero cha zitsanzo: Max.100MHz pa njira
●Miyezo osiyanasiyana: 0.1pc-10000nc.
●Mtundu wamphamvu:> 80db.
●Kuyeza pafupipafupi gulu: 10kHz-1MHz pa 3db.
●Kuchuluka kwa mphamvu zoyesa: 50-400Hz.
●Fyuluta yotheka
Mafupipafupi otsika: 10K, 20K, 40K, 80K;
Nthawi zambiri: 100K, 200K, 300K, 1000K.
●Kutentha kwachilengedwe: -15 ℃--50 ℃
●Chinyezi chachibale: ≤95% (20 ℃)
●Kutalika: ≤3000m.
●Kuthekera kwamphamvu: 5000V pa doko lililonse lolowera ndi magetsi (zabwino, zoyipa ndi AC)
●Kuyika kwamphamvu: AC220V ± 10%, 45-65Hz, mphamvu <500W.
●Kulemera kwake: pafupifupi 15kg.
●kukula: 58 * 36 * 32CM