GDJW-40B Wireless Insulator Tester
GDJW-40B itha kugwiritsidwa ntchito kuyesa ma voltages ogawa a insulator yoyimitsidwa yoyimitsidwa kapena kuzindikira kwa labotale kwa insulator yoyimitsidwa, ndikuthandizira kuzindikira zovuta zobisika zamkati mwa insulator, kukonza kudalirika kwa magwiridwe antchito a gridi yamagetsi, ndikuwongolera. mphamvu yogwira ntchito ya ogwira ntchito pamzere omwe amayesa amoyo.Izi zimatengera kutumizira opanda zingwe, mtunda wolumikizana pakati pa chowunikira ndi cholumikizira chamanja utha kufika 100m pamwamba, Pangani njira yoyezera kukhala yotetezeka komanso yodalirika, yachangu komanso yolondola.Kuphatikiza apo, chidachi chimakhala ndi magwiridwe antchito amphamvu kwambiri oletsa kusokoneza, kutsatira mokwanira (EMC) zofunikira zofananira, kusinthira kuzinthu zosiyanasiyana zosokoneza ma elekitiroma.
●Mphamvu yamagetsi: 35-1000KV, milingo yosiyanasiyana yamagetsi imagwira ntchito.
●Voltage Kuyeza osiyanasiyana: 0-40kV (wapadera voteji akhoza makonda).
●Cholakwika choyezera: ≤± 1%.
●Chiwerengero cha zitsanzo: 10 times/S.
●Zosintha za tsiku: sinthani tsiku ndi nthawi, kuti muthandizire ogwiritsa ntchito kusakatula, kuwona mbiri yakale.
●Makonda a nthawi yowunikira kumbuyo: kuwala kosalekeza, kosalekeza, mphindi 0-999 zitha kukhazikitsidwa.
●Zikhazikiko zozimitsa zokha: ayi, mphindi 0-999 zitha kukhazikitsidwa.
●Mtunda wotumizira wa terminal yogwira pamanja ndi chowunikira ndi ≤100m.
●Mapangidwe amitundu yambiri, kugwiritsa ntchito mwamphamvu, otetezeka komanso osavuta.
●Mapangidwe ophatikizana a Universal, amathandizira kuti azitha kusintha momwe amayezera muyeso malinga ndi kuyimitsidwa kwa chingwe cha insulator.
●Kutetezedwa kawiri, mphamvu zotsutsana ndi kusokoneza, kutsata kwathunthu miyezo ya EMC.
●Mawonekedwe apadera a makina amunthu, osavuta kugwiritsa ntchito.
Mulingo wamagetsi wamagetsi | 0-40kV (voteji wapadera akhoza makonda) |
Cholakwika pakuyezera | ±1% |
Kusamvana | 0.01 kV |
Chiwerengero cha zitsanzo | 10nthawi/S |
Ntchito panopa | ≤120mA(Terminal yogwira pamanja),≤40mA(Detector) |
Magetsi | 2*1.5 VBatire yowuma ya AA (yogwira pamanja) 2*1.5 VAAA batire yowuma (Detector) |
Nthawi yogwira ntchito | ≥12h |
Mtunda wotumizira | ≥100m (magetsi okwanira) |
Onetsani | Chiwonetsero cha LCD, chikhoza kuwonetsedwa bwino pansi pa kuwala kwa dzuwa. |
Kutentha kwa ntchito | -35 ℃---+60 ℃ |
Kutentha kosungirako | -40 ℃---+65 ℃ |
Chinyezi chachibale | ≤90%RH Zopanda condensate |
Ayi. | Kusintha koyambira | Chigawo | Qty. | Ndemanga |
1 | Chogwirizira pamanja | set | 1 | |
2 | Chodziwira chodzipatulira | chidutswa | 1 | |
3 | A,B Chodziwira | mizu | 2 | |
4 | AA Batire Youma (1.5 V) | gawo | 2 | |
7 | AAA Batire Youma (1.5 V) | gawo | 2 | |
8 | Lowetsani chotengera chonyamula | chidutswa | 1 | |
9 | 220kV Insulation ndodo | mizu | 1 | ≤220k paV kulimbana ndi4magawo4M insulation rod,≥330 kV kufanana ndi6 magawo6M insulation rod |
10 | Buku la ntchito | kope | 1 | |
11 | Lipoti la mayeso | kope | 1 | |
12 | Khadi ya chitsimikizo | kope | 1 | |
13 | Mndandanda wazolongedza | kope | 1 |