GDRB-F Transformer Winding Deformation Tester (SFRA & Impedance Method)
●Kupeza ndi kuwongolera pogwiritsa ntchito liwiro lalikulu, lophatikizika kwambiri la microprocessor.
●Kulumikizana kwa USB komwe kumagwiritsidwa ntchito pakati pa laputopu ndi chida.
●Zida zopangira zida zimagwiritsa ntchito ukadaulo wodzipatulira wa DDS wa digito wothamanga kwambiri (USA), womwe umatha kuzindikira zolakwikazo ngati mapindikidwe okhotakhota, opindika, osunthika, opendekeka, opindika pang'onopang'ono komanso kulumikizana kwapakati pagawo.
●Zitsanzo zothamanga kwambiri zapawiri-zapawiri 16-bit A/D (pamayesero a m'munda, sunthani chosinthira chapampopi, ndipo mawonekedwe opindikira akuwonetsa zosintha zowonekera).
●Kukula kwa chizindikiro kumasinthidwa ndi mapulogalamu, ndipo mtengo wapamwamba wa matalikidwe ndi ± 10V.
●Kompyutayo imangosanthula zotsatira zoyeserera ndikupanga zolemba zamagetsi (Mawu).
●Chidacho chili ndi magawo awiri oyezera: kuyeza kwa ma frequency a liniya ndi kuyeza kwa ma frequency a segment, kumagwirizana ndi kuyeza kwa magulu awiri aukadaulo ku China.
●Makhalidwe amplitude-frequency amagwirizana ndi zoyeserera zaukadaulo zamtundu wa amplitude-frequency tester.X-coordinate (kawirikawiri) imakhala ndi indexing ya mzere ndi logarithmic indexing, kotero wogwiritsa ntchito amatha kusindikiza mizere yokhotakhota ndi logarithmic indexing.Wogwiritsa akhoza kusankha kaya malinga ndi zosowa zenizeni.
●Dongosolo losanthula deta yodziwikiratu.
Kuyerekeza kopingasa kwa kufanana kozungulira pakati pa magawo atatu A, B ndi C
Zotsatira zake ndi izi:
① Kusasinthika kwabwino
② Kusasinthasintha
③ Kusakhazikika bwino
④ Kusasinthika koyipa
Kuyerekeza kwa nthawi yayitali AA, BB, CC imayitanira deta yoyambirira ndi zomwe zilipo pakalipano mu gawo lomwelo la kuyerekezera kozungulira kozungulira.
Zotsatira zake ndi:
① Kumangirira mwachizolowezi
② Kupindika pang'ono
③ Kupindika pang'ono
④ Kusinthika kwakukulu
●Mawu pakompyuta chikalata akhoza kwaiye kwa kupulumutsa ndi kusindikiza.
●Chidacho chimatha kukwaniritsa zofunikira zaukadaulo wamagetsi a DL/T911-2004 "Kusanthula kwamayankho pafupipafupi pamapindikira osinthira magetsi".
●The transformer winding deformation tester imapangidwa ndi gawo loyezera komanso gawo la pulogalamu yowunikira.Gawo loyezera limayang'aniridwa ndi makina othamanga kwambiri a single-chip, ndipo amapangidwa ndi kupanga ma siginecha ndi kuyeza kwa chizindikiro.Gawo loyezera limagwiritsa ntchito mawonekedwe a USB kuti alumikizane ndi piritsi kapena laputopu.
●Pakuyesa, basi yolumikizira yokha ya transformer iyenera kuchotsedwa, ndipo mayeso onse amatha kumalizidwa popanda kupachika chivundikiro ndikuchotsa thiransifoma.
●Chidacho chimakhala ndi ma frequency a liniya pafupipafupi kusesa kuyeza dongosolo la kuyeza, kusesa pafupipafupi kusesa kuyeza pafupipafupi mpaka 10MHz, nthawi yojambulira pafupipafupi imatha kugawidwa mu 0.25kHz, 0.5kHz ndi 1kHz, kuti apereke kusanthula kowonjezereka kwa thiransifoma. kusintha.
●Chidacho ndi chanzeru kwambiri, chosavuta kugwiritsa ntchito, ndipo chimakhala ndi ntchito zingapo monga kusintha kwamtundu wodziwikiratu komanso kusintha kwafupipafupi kwa sampuli.
●The mapulogalamu utenga mawindo nsanja, n'zogwirizana ndi Windows98/2000/winXP/Windows7 dongosolo.Patsani ogwiritsa ntchito mawonekedwe osavuta komanso osavuta kugwiritsa ntchito.
●Perekani kusanthula koyerekeza kwa mapindikidwe a mbiriyakale, kutha kuyika zowonera zingapo zamapindidwe akale nthawi imodzi, kumatha kusankha mwapadera mpata uliwonse wowunikira mopingasa komanso moyima.Okonzeka ndi katswiri wanzeru kusanthula ndi matenda dongosolo, akhoza kudziwira yekha mmene thiransifoma windings, katundu 6 zokhota pa nthawi yomweyo, ndi basi kuwerengera magawo oyenerera pamapindikira aliyense, kudziwa mapindikidwe ma windings, ndi kupereka kuzindikira komaliza.
●Ntchito yamphamvu yoyang'anira mapulogalamu, poganizira zofunikira zogwiritsa ntchito pamalowo, ndikusunga zokha magawo achilengedwe kuti apereke maziko ozindikira mapindidwe a thiransifoma.Deta yoyezera imasungidwa yokha ndipo imakhala ndi ntchito yosindikiza mitundu, yomwe ndi yabwino kuti ogwiritsa ntchito apereke malipoti oyesa.
●Pulogalamuyi ili ndi mawonekedwe osavuta kugwiritsa ntchito.Miyezo yambiri ndi zinthu zomwe mungasankhe.Magawo atsatanetsatane a thiransifoma amatha kusungidwa kuti adziwe matenda, ndipo palibe chifukwa cholowera patsamba, ndipo wogwiritsa ntchito amatha kuwonjezera ndikusintha zambiri pambuyo pake, zomwe ndizosavuta kugwiritsa ntchito.
●Mapulogalamuwa ali ndi nzeru zapamwamba.Zizindikiro zolowetsamo ndi zotuluka zitalumikizidwa ndikuyika magawo, ntchito zonse zoyezera zitha kumalizidwa, ndipo mapindikidwe a mbiri yakale atha kutsegulidwa muyeso nthawi iliyonse kuti muwonere kufananiza ndikuyimitsa.
●Nthawi yofunikira pakuyezera gawo lililonse ndi masekondi osakwana 60.Nthawi yonse yoyezera mapindikidwe opindika a thiransifoma yamagetsi yokhala ndi ma windings apamwamba, apakati komanso otsika (kuthekera ndi mulingo wamagetsi siwochepa) ndi zosakwana mphindi 10.
●Poyezera thiransifoma, ogwira ntchito pamawaya amatha kuyika mosabisa mawu olowera ndi zotuluka, zomwe sizingakhudze zotsatira zake.Ogwira ntchito zamawaya amatha kukhala pa thanki ya thiransifoma popanda kutsika, kuchepetsa kuchuluka kwa ntchito.
Scan mode:
1. Liniya sikani kugawa
Kusanthula muyeso: (10Hz) - (10MHz) 40000 malo ojambulira, kusanja 0.25kHz, 0.5kHz ndi 1kHz.
2. Gawo kusesa pafupipafupi kuyeza kugawa
Sesa pafupipafupi kuyeza osiyanasiyana: (0.5kHz) - (1MHz), 2000 sikani mfundo;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Zina mwaukadaulo magawo:
1. Muyezo wa matalikidwe osiyanasiyana: (-120dB) mpaka (+20 dB);
2. Kuyeza kwa matalikidwe olondola: 1dB;
3. Kusesa pafupipafupi: 0.005%;
4. Kusokoneza kwa ma signature: 1MΩ;
5. Kusokoneza kwa chizindikiro: 50Ω;
6. Signal linanena bungwe matalikidwe: ± 20V;
7. Mu-gawo mayeso obwerezabwereza mlingo: 99.9%;
8. Zida zoyezera miyeso (LxWxH): 340X240X210 (mm);
9. Chida cha aluminiyamu bokosi dimension (LxWxH): 370X280X260 (mm);Waya bokosi zotayidwa aloyi bokosi (LxWxH) 420X300X300 (mm);
10. Kulemera konse: 10kg;
11. Kutentha kwa ntchito: -10 ℃ ~ + 40 ℃;
12. Kutentha kosungira: -20 ℃ ~ + 70 ℃;
13. Chinyezi chachibale: <90%, Non-condensing;