GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment

GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment

Brief Description:

Ultrasonic Flaw Detector is a non-destructive testing device used for detecting internal mechanical damages for electrical equipment.


Product Detail

Product Tags

Applications

It detects internal flaws of electrical equipment, such as bushings, bus bars, wire clamps, transformer tank, current&voltage transformers, surge arresters, generator bearing equipment, and porcelain pillar type insulators, etc.

Features

TFT true color screen.
High accuracy and wide applications.
High sensitivity of flaw detection, up to 110db.
Built-in standard curves and test block for pillar type insulators. The device alarms if internal crackle flaws are super-standard.
Automatic calibrations for probe and curvature surface, which optimizes the coupling between the probe and test object and ensures accuracy.
Aluminum alloy chassis, which has excellent anti-interference performance. Low noise and high signal-to-noise ratio.

Specifications

Working frequency: 0.5~20 MHz
Gain adjustment: 110dB (manual 0.1dB/2dB/6 dB step-wise)
Detection range: 0~9999mm longitudinal wave (steel)
Velocity Range: 0 ~ 9000 m/s
Dynamic range: ≥ 32dB
Vertical linearity error: ≤ 3%
Horizontal linearity error: ≤ 0.1%
Resolution: > 42dB (5P14)
Surplus sensitivity: > 62dB (200mmΦ2 depth, flat-bottom hole)
Data saving capacity: 21 groups of detection data, 1000 echoes
Power supply/voltage: DC 7.4V lithium battery, continuous working for 12 hours; AC220V
Environmental temperature: -25 to 50° C
Related humidity: 20%-95% RH
Dimensions: 210*168*50(mm)
Weight: 1.8kg (including built-in battery)


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us