GDUD-PTM Akupanga Chowunikira Chowunikira Kwa Magetsi Amphamvu Tower
●TFT mtundu weniweni wa skrini.
●Pogwiritsa ntchito ukadaulo wotsogola wophatikizidwa wa digito, zisonyezo zamagetsi pazidazi zimapangidwa ndikupangidwa molingana ndi EN 12668.1 - 2000 standard.
●Batire ya lithiamu polymer yapamwamba komanso yotetezeka komanso ukadaulo wowongolera mphamvu, alamu yokhayokha komanso chitetezo.Chowonetsera choyimirira chodziwikiratu chikhoza kukhazikitsidwa kuti chipangitse kuti chipangizochi chikhale chogwiritsa ntchito mphamvu zambiri komanso chokhalitsa, ndikuwonetsetsa kuti chiwopsezo chikuwonekera mosalekeza komanso moyenera.
●Mapulogalamu ogwiritsira ntchito omwe amaphatikiza ntchito zanzeru komanso zamphamvu zosinthira, mawonekedwe a ogwiritsa ntchito molunjika ndi mawonekedwe ogwiritsira ntchito, kapena makina ogwiritsira ntchito batani limodzi la digito.
●Zodziwikiratu zazikuluzikulu zosinthira njira, yabwino kwa ogwiritsa ntchito pazinthu zosiyanasiyana zozindikirika.Kusungirako deta mwamphamvu komanso kusanthula kosasunthika, kuphatikizidwa ndi tsiku lozindikira zolakwika zenizeni ndi nthawi yolondolera ndi kujambula, kumapangitsa kuzindikira kukhala kosavuta.
●Ndi variable m'lifupi lalikulu lalikulu yoweyula pulse jenereta, ndi variable voteji transmitter kupeza variable kufalitsa mphamvu.Zosintha zamagawo angapo zimalola kuti kafukufukuyu agwirizane bwino ndi chidacho.
●Makhalidwe abwino amplifier ndi mawonekedwe a frequency band.Amplifier ili ndi kulondola kwa 0.1dB, yokhala ndi machitidwe opangira ma bandi ambiri ndi opapatiza, ndipo ma frequency a probe amatha kuyeza nthawi yeniyeni, yomwe imapereka zotsatira zabwino zodziwikiratu wogwiritsa ntchito akazindikira zinthu zosiyanasiyana.
●Ndi mawonekedwe otambalala (mpaka 6 metres) komanso kusanja kwamphamvu kwamphamvu, min.0.1mm mosalekeza chosinthika osiyanasiyana.Sankhani mtundu woyenera ndi kafukufuku wofananira kuti musankhe bwino pafupi ndi gawo.
●Makina abwino kwambiri othamanga kwambiri munthawi yeniyeni komanso mawonekedwe okhathamiritsa a kubwereza kubwereza pafupipafupi ntchito kuti akwaniritse zotsatira zabwino za mbewu za kristalo komanso mtunda wodziwikiratu.Chiwonetsero cha echo chimakhala ndi mphamvu ndipo palibe hysteresis.
●Ma calibrations odziwikiratu a probe ndi kupindika pamwamba, komwe kumathandizira kulumikizana pakati pa probe ndi chinthu choyesera ndikuwonetsetsa kulondola.
●Ndi distance-amplitude (DAC) curve function, phokoso loyendetsedwa ndi pulogalamu komanso kuwongolera ma alarm.
●Ndi mawonekedwe othamanga kwambiri a USB, kulumikizana mosavuta ndi kompyuta, kuthandizira kasamalidwe ka makompyuta ndikukonza mapulogalamu pa intaneti.
●Nyumba yopepuka ya aluminiyamu yopangidwa ndi manja, yomwe ili ndi ntchito yabwino kwambiri yolimbana ndi kusokoneza.Imakumana ndi gulu lachitetezo cha IP65.
Kutumiza/Kulandira
Kutumiza magetsi | 600V |
Zitsanzo pafupipafupi | 100MHz (Max.) |
Kubwereza pafupipafupi kwa kugunda | 60Hz pa |
Kusagwirizana kwa impedance | 50Ω/500Ω |
Njira yogwirira ntchito | Kudzipatsira ndi kulandira / Kutumiza kumodzi ndikulandila kumodzi / kulowa mkati |
Kusamvana | ≥36dB(5N14) |
Avereji ya phokoso lamagetsi | ≤ |
Kukulitsa/zindikira
Sensitivity malire | ≥60dB(200mm kuya, Φ2Flat pansi dzenje) |
Kupindula | 0~110dB, sitepe 0dB/0.1dB/1dB/2dB/6dB kuti musankhe |
Kulondola kwa Amplifier | ±1dB |
Cholakwika pamzere woyima | ≤3% |
Kupindula kokha | 10% -90% |
Dynamic Range | ≥35dB |
Nthawi yoyambira
Kuzindikira | 10-6000mm, 0.1,1 ndi 10mm sitepe basi zoikamo |
Kulakwitsa kwa mzere wopingasa | ≤0.1% |
Liwiro la mawu | 1000-16000m/s, sitepe ndi 1m/s |
Kusintha kwa Zero (kuchedwa kwa kafukufuku) | 0-500.0us |
Kuwonetsa pansi | 0-1000.0mm;0.1, 1mm sitepe basi zoikamo |
Mpinda
DAC curve | Distance-amplitude curve(DAC), 2~10pcs reference point |
Ma 4 okhotakhota owonjezera a dB |
Kusintha kwa Signal
Kuponderezedwa kwa chizindikiro | 0-90%, mzere |
Chipata chozindikira (Chidutswa chimodzi) | Poyambira / m'lifupi / kutalika kumasinthika mosalekeza |
Alamu yabwino/yoipa pachipata | |
Kuwongolera (kumveka ndi alamu yopepuka). | |
Kusankha malo oyezera ma sign pachipata | |
Njira yoyezera | Njira yomveka / mtunda wopingasa/kuzama kwa kuwerengera nthawi yeniyeni |
TOF (nthawi yonyamuka) muyeso wanthawi yeniyeni yowerengera | |
Kuwonetsa kwamphamvu kwa njira yosinthira mawu | |
Kuwerengera muyeso wokhazikika | |
Kuchulukitsitsa kwachulukidwe ndi kaimidwe kosafunikira |
Ntchito yozindikira zolakwika
Channel | 20magulu |
Kusungirako | Zizindikiro 500 za echo |
Onetsani | Kuundana kwathunthu / kuzizira kwathunthu |
Envelopu yopindika | Chiwonetsero cha envelopu yapamwamba kwambiri |
Nthawi yeniyeni | Kutsata tsiku/nthawi, nthawi yokhazikika ya wotchi |
Chiyankhulo | Doko la USB, lothandizira kulumikizana ndi makompyuta ndi kasamalidwe |
Onetsani
Onetsani | Kuwala kwambiri, mtundu weniweni wa TFT chiwonetsero, mainchesi 5.7 |
pafupipafupi | NTSC (60Hz) |
Kapangidwe ndi malo ogwiritsira ntchito
Batiri | Lithium polima batire, nthawi yogwira ntchito ≥ maola 10 |
Dimension ndi kulemera | 210mmx165mmx50mm, 1.8kg (ndi batire) |
Kutentha kwa chilengedwe | -5 ℃--60 ℃ |
Chinyezi chachibale | 20-90% RH |
Main Unit | 1 chidutswa |
Adaputala yamagetsi | 1 chidutswa |
HF anti-EMI probe chingwe | 2 zidutswa |
Chingwe cha USB | 1 chidutswa |
Fufuzani | 2 ma PC |
Module | 1 chidutswa |
CD | 1 chidutswa |
Buku Logwiritsa Ntchito | 1 kopi |
Lipoti la Mayeso a Fakitale | 1 kopi |