GDYB-S3 Three Phase Energy Meter Test System (maudindo atatu)
Kulondola kwadongosolo: 0,1%;
magawo atatu gwero parameter:
a.Mphamvu yamagetsi:
3 * 57.7VY 3 * 100V ∆ ;
3*220V Y 3*380V ∆;
Mtundu wosinthika 0~120% wosinthika mosalekeza
Kusintha kwabwino: bwino kuposa 0.01%
b.Zotulutsa zamakono: 25mA, 0.1A, 1A, 5A, 25A, 100A;
Mtundu wosinthika 0~120% wosinthika mosalekeza
Kusintha kwabwino: bwino kuposa 0.01%
Kutulutsa kwapang'onopang'ono: 1mA (kulondola: <5%)
c.Linanena bungwe mphamvu: (voltage dera) 3 * 50VA
(dera lapano) 3 * 150VA
d.Linanena bungwe voteji, panopa, mphamvu bata: ≤0.02%/120S
e.Kusokonekera kwamagetsi otulutsa ndi mawonekedwe apano: ≤0.5%
f.Symmetry ya ngodya zitatu: pakati pa 120 ° ± 0.3 °
g.Mafupipafupi osiyanasiyana: 45Hz ~ 65Hz, sitepe: 0.01Hz
h.Gawo la ngodya: -180 ° ~ 180 °, sitepe: 0.01 °
ndi.Kuwonetsa kulondola kwa mita: Voltmeter, ammeter: ± 0.01%
Gawo mita: ± 0.01 °
pafupipafupi mita: ± 0.01Hz
Zochepa Zotulutsa zamakono: 1mA;kulondola: ≤5%;
Mphamvu zotulutsa (mamita 20)
Kutulutsa kwamagetsi: 800VA;
Zotulutsa zamakono: 2500VA;
Voltage & kusintha kwatsopano
Mtundu wosinthika: (0% ~ 120%) x muyeso woyezera;
Kuwongolera kosinthika: 10%, 1%, 0.1%, 0.01%;
Kusintha gawo:
Mtundu wosinthika: 0 ° ~ 360 °;
Kuwongolera kosinthika: 10 °, 1 °, 0.1 °, 0.01 °;
Kusintha pafupipafupi:
Mtundu wosinthika: 45Hz ~ 65Hz;
Kuwongolera kosinthika: 1Hz, 0.1Hz, 0.01Hz;
Kukhazikika kwa mphamvu zotulutsa: ≤0.05%/120S;
Mphamvu yamagetsi yotulutsa & kusokonekera kwapano:
Mphamvu yamagetsi: ≤0.5%;
Panopa: ≤0.5%;
Zokonda za Harmonic:
Nambala ya Harmonic: 2 ~ 21 nthawi;
Harmonic content: panopa 2 ~ 21 nthawi ≤40% (zokhudzana ndi mafunde ofunikira);
voteji 2 ~ 21 nthawi ≤40% (zokhudzana ndi mafunde ofunikira);
Gawo la Harmonic: 0 ° ~ 359.99 °;
Chida chowunikira:
Mawonekedwe olondola a mita: Voltage: 0.01%;
Masiku ano: 0.01%;
Mphamvu: 0.01%;
Gawo: 0.01;
pafupipafupi: 0.01;
Insulated 1: 1 thiransifoma yamakono parameter:
Kulondola: 0,01%;
Kutulutsa mphamvu: 60VA;
Muyezo wamakono: 1mA~120A (1:1);
Main performance index
a) Kulondola: 0.01% (COS∮=0.5C…1…0.5L);
b) Mafupipafupi ovoteledwa: 50Hz/60Hz ± 5%;
c) Pakali pano: 3 × 0.001-120A;
d) Sekondale yamakono: 3 × 0.001-120A;
e) Zotulutsa (gawo lililonse):
0.5W (zotulutsa zosiyanasiyana: 0.001-1A);
0.7V yogawidwa ndi mtengo wamakono (zotulutsa zosiyanasiyana: 1-120A);
f) Mphamvu yotulutsa mphamvu: Max.0.5V (zotulutsa zamakono Max. 120A);
Kukula kwa transformer yamakono: 265 x 200 x 240 mm (L x W x H);
Kulemera kwake: 12kg;
Dimension:
Gwero lolamulira: 610 x 800 x 1920mm (L x W x H);
Kuyika mita: 2350 x 750 x 1850mm (L x W x H);