GDYM-1A Single Phase Electric Energy Meter Calibrator
GDYM-1A Single phase Electric Energy Meter Calibrator ndi chida choyezera chamitundu yambiri chomwe chili ndi digito, ntchito zambiri komanso zolondola kwambiri.Izo osati athe calibrating cholakwa, komanso kuyeza voteji, panopa ogwira mtengo, mphamvu yogwira, zotakataka, mphamvu zoonekera, mphamvu pafupipafupi, mphamvu factor, gawo ubale, etc. Ndi bwino makamaka calibrating kulondola muyeso wa Gawo limodzi lamagetsi amagetsi amagetsi mugawo lamagetsi.
Kuchita kosavuta komanso kofulumira, njira zonse zogwirira ntchito zikuwonetsedwa pazenera.
●Kuyesa mita yamagetsi yamagetsi yoyezera ndikuyesa kuchuluka kwamagetsi otsika.
●Pogwiritsa ntchito ukadaulo waposachedwa wa 32-bit 150MHz DPS pachimake, chosinthira cholondola kwambiri cha 16 pang'ono, cholakwikacho ndi chokhazikika komanso cholondola ndi chapamwamba (izi zimakhala ndi kusiyana kosiyana ndi calibrator yagawo limodzi yokhala ndi chip mita).
●Chojambula chachikulu cha LCD chowoneka bwino, chimawonetsa magawo osinthika, ma harmonic, magawo amagetsi, zolakwika ndi data yonse yoyezera.
●Chingwe chamakono chimagwiritsidwa ntchito kuyerekezera zomwe zikuchitika ndi katundu, zomwe zimathandizira kuti ntchitoyo igwire ntchito ndikuwongolera bwino ntchito.Zomwe zilipo pa terminal ndi clamp komanso mphamvu zawo ndi kuchuluka kwa mphamvu zidzawonetsedwa nthawi yomweyo.
●Pogwiritsa ntchito cholumikizira cha 500A ndi cholumikizira chaching'ono chapano kuti muyeze kuchuluka kwamagetsi otsika a CT.
●Kuyeza deta ya harmonic kuchokera ku 2-43 nthawi, zamakono ndi magetsi zidzawonetsa nthawi yeniyeni mawonekedwe aliwonse, zomwe zimathandiza kuweruza malo omwe ali pamalopo.
●Kuwerengera kuchuluka kwa mita yamphamvu munthawi imodzi yamphamvu yamagetsi.
●Sungani deta ya mamita 1000.
●Lumikizani ndi PC ndi mawonekedwe a RS232 mndandanda wolumikizana.
●Ndi kutsika kwapang'onopang'ono kugunda kwamphamvu, koyenera kudzifufuza ndikuwunika.
●Calibrator imachenjeza ndi phokoso ndi kuwala pamene ikupereka 380V ku mzere woyesera magetsi.
●Pamene kayeseleledwe katundu panopa mzere molakwika olumikizidwa kwa mzere wosalowerera ndale wa mita, woyamba basi chitetezo si linanena bungwe panopa.Mukapanganso kugwirizana kwa zolakwika, fuse yachiwiri yotetezera idzawotchedwa, yomwe imagwira ntchito chitetezo chamtheradi.Calibrator idzachira pambuyo posintha fusesi.
●Fuseyo idzawotchedwa pamenemzere wokakamiza unagunda 220V, chowongolera chidzachira pambuyo posintha fusesi.
Muyezo Range | Kulondola | ||
Voteji | 10-300 V | ± 0.1% | |
Simulation Panopa | 5A | ±20% | |
Clamp Yamakono | 100A, 500A | ± 0.3%, ± 0.5% | |
Terminal Yapano | 0.05-10 A | ± 0.1% | |
Mphamvu | Clamp Yamakono | 100A, 500A | ± 0.3%, ± 0.5% |
Pokwerera | 10A | ± 0.1% | |
Phase Angle | -180-+180° | ±0.1° | |
pafupipafupi | 45-55Hz | ± 0.01Hz | |
Mphamvu Zamagetsi | 100A Clamp (yaing'ono) | 0.25A-110A | ± 0.3%, ± 0.5% |
Mtengo wa 500A | 25-1000A | ± 0.5% | |
Mtundu Wowonetsera | 100A Chingwe Chamakono: 0.01A-110A | ||
Pokwerera: 0.01A-10A | |||
Electric Energy Pulse | FL=1000 imp/kW.h | ||
Voltage yogwira ntchito | AC 100 - 300 V | ||
Kutentha kwa Ntchito | -25 ℃~45 ℃ | ||
Chinyezi Chogwira Ntchito | <95% Palibe condensation | ||
Kulemera | <1kg | ||
Voliyumu | 215 * 105 * 70mm |
GDYM-1A Calibrator | 1 seti |
100A clamp mita | 1 zidutswa |
Management Software (CD-ROM) | 1 chidutswa |
Electronic meter pulse line | 1 chidutswa |
Chingwe chamagetsi | 1 chidutswa |
Chingwe chamagetsi | 1 chidutswa |
232 njira yolumikizirana | 1 chidutswa |
Photoelectric mutu | 1 chidutswa |
0.5A Fuse | 1 chidutswa |
Kalasi ya zida | 1 chidutswa |
Pamanja | 1 kopi |