GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester
GDZRC-40U (GDJRC-50U) DC Winding Resistance Tester idapangidwa kuti iziyezera kukana kwa DC kwa zida zolumikizira, monga ma transformer ndi ma inductors amagetsi.Ili ndi mawonekedwe oyezera mwachangu, kukula kochepa, kulemera kopepuka, kutulutsa kwakukulu kwapano, ntchito zodzitchinjiriza bwino, kubwereza bwino, luso loletsa kusokoneza, kulondola kwakukulu, zomwe zimapangitsa kuti ikhale chida choyenera kuyeza kukana kwa DC kwa thiransifoma yokhotakhota komanso yokwera. zida zophunzitsira.
●Imayendetsedwa ndi chip microcomputer yothamanga kwambiri, yodziwikiratu komanso yosavuta kugwiritsa ntchito.
●Imatengera ukadaulo watsopano wopangira magetsi okhala ndi masitepe angapo aposachedwa komanso mitundu ingapo yoyezera, yomwe ili yoyenera kuyeza kukana kwa DC kwa ma transformer akulu ndi apakatikati.
●Ntchito zoteteza bwino, zomwe zimatha kuteteza chidacho ku zotsatira za counter EMF, ndi magwiridwe antchito odalirika.
●Alamu yotulutsa mawu, chisonyezero chomveka bwino, ntchito yolakwika.
●Kuthamanga kwachangu kuyankha, chosinthira chojambulira chotsitsa chimatha kusinthidwa mwachindunji muyeso, ndipo chidacho chimatsitsimutsa deta.
●Ukadaulo wanzeru wowongolera mphamvu.Chidacho nthawi zonse chimagwira ntchito ndi mphamvu zochepa, zomwe zimapulumutsa mphamvu ndikuchepetsa kutentha bwino.
●65K mtundu weniweni wa LCD wocheperako 320X240 ma pixel ang'onoang'ono.
●Zokhala ndi wotchi ya kalendala komanso ntchito yosungiramo data yolephera mphamvu, yomwe imatha kusunga ma data 1000 a mayeso ndipo imatha kuwunikiridwa nthawi iliyonse.
●Zokhala ndi RS232 (mawonekedwe osungidwa) ndi mawonekedwe a USB (osungirako USB).
Zotulutsa zamakono | <5mA, 2.5A, 5A, 10A, 20A, 40A | |
Min.kuthetsa | 0.1μΩ | |
Muyezo osiyanasiyana | (GDZRC-50U: 40μΩ~400mΩ) 50μΩ~500mΩ 100μΩ~1Ω 500μΩ~2Ω 1mΩ~4Ω 2mΩ~8Ω 10Ω~20KΩ | (GDZRC-50U: 50A) 40 A 20A 10A 5A 2.5A <5mA |
Kulondola | ±(0.2%+2 manambala) | |
Kutentha kwa ntchito | 0 ~ 40 ℃ | |
Chinyezi | <90% RH (nokuchepetsa) | |
Kukula | 325mm×240mm×275mm (L×W×H) / GDZRC-50U: 400mm×225mm×350mm (L×W×H) | |
Kulemera | 15kg (popanda mayeso waya) / GDZRC-50U: 17kg (popanda mayeso waya) mayeso waya bokosi: 3kg |
Woyesa | 1 seti |
Chingwe champhamvu | 1 chidutswa |
Waya yoyesera (yofiira yakuda iliyonse yokhala ndi chotchinga) | 2 zidutswa |
Sindikizani pepala | 2 mitu |
Fuse | 2 zidutswa |
232 serial waya | 1 chidutswa |
Shunt | 1 chidutswa |
Buku Lolangiza | 1 chidutswa |
Kupita kwa QC | 1 chidutswa |
Mndandanda wazolongedza | 1 chidutswa |
Lipoti la mayeso a fakitale | 1 chidutswa |