GDWR-5A Earth Resistance Tester ndi chida choyesera cholondola kwambiri chomwe chimagwiritsidwa ntchito m'magawo osiyanasiyana monga ma substation poyesa kukana kwapansi ndi magawo ena okhudzana nawo.Chidacho chili ndi mawonekedwe a voliyumu yaying'ono, kulemera kopepuka, kunyamula kosavuta, kuchitapo kanthu mwamphamvu kotsutsana ndi kusokoneza komanso kulondola kwambiri.
GDJR-200D Single Phase Electronic Thermal Relay Calibrator imagwiritsidwa ntchito makamaka pakukhazikitsa ndi kutsimikizira zida zosiyanasiyana zamagetsi.Ndi mbali ya kapangidwe wololera, ntchito yabwino ndi mphamvu yaikulu linanena bungwe, chimagwiritsidwa ntchito mu malo mayeso magetsi dongosolo mphamvu, njanji, petrochemical, zitsulo ndi mabizinesi migodi.
Mphamvu ya thiransifoma yokhotakhota mapindikidwe tester (njira yoyankhira pafupipafupi) imachokera pakuyezetsa magawo amtundu wa thiransifoma mkati, imatengera njira yowunikira ma frequency amkati (FRA), imatha kuweruza molondola zolakwa zamkati za thiransifoma.
GD8000C quantitatively leak online monitoring system imagwiritsidwa ntchito makamaka mu chipinda chosinthira cha 35KV SF6 ndi chipinda cha 500KV, 220KV, 110KV GIS m'chipinda chocheperako kuti chiwunikire kutayikira kwa mpweya wa SF6 mu chipinda cha SF6 chophatikiza zida zamagetsi ndi mpweya womwe uli mumlengalenga munthawi yeniyeni. .
Test Test Test ndi njira yofunika kwambiri yodzitetezera pazida zamagetsi.Imagawidwa m'magawo awiri: AC ndi DC kupirira mayeso amagetsi.
GDFR-C1 mndandanda wa mita ya digito ya AC/DC ndi chida chomwe chimayesa magetsi a AC ndi DC.Zimapangidwa ndi voltage divider ndi chida choyezera.
GDFR-D1 Series AC/DC mita ya digito ndi chida chomwe chimayesa magetsi a AC ndi DC.Mamita a digito ndi zogawa zili ndi gawo limodzi.
GDZJ-5S imagwiritsidwa ntchito poyesa mphamvu yamagetsi yamagetsi yagawo limodzi, 3-gawo motor, Micro motor, Special mota, mota yamagetsi, thiransifoma (kuphatikiza switching mode power supply thiransifoma), relay ndi zida zamagetsi zokhotakhota.
GDZJ-30S imagwiritsidwa ntchito poyesa mphamvu yamagetsi yamagetsi ya 10kV, HV ndi LV mota, mota ya AC/DC, mapindikidwe a thiransifoma ndi mapindikidwe a koyilo.
GDJF-2007 Digital Partial Discharge Analyzer imagwiritsidwa ntchito kwambiri pozindikira kutulutsa kwapang'onopang'ono kwa zida zamagetsi apamwamba monga zosinthira mphamvu, chosinthira zida, HV circuit breaker, GIS, Zinc oxide surge arrester, chingwe chamagetsi.
The GDPD-414H handheld Partial Discharge Detector imagwiritsa ntchito njira yoyesera mphamvu yanzeru mwachangu (Soft No. 1010215, nambala yolembera chizindikiro 14684481), yomwe imatha kusinthira masensa osiyanasiyana molingana ndi zinthu zosiyanasiyana zoyesa.