Zida Zoyesera za Transformer

  • GDB-D Transformer Turn Ratio Tester

    GDB-D Transformer Turn Ratio Tester

    GDB-D Transformer turn ratio tester idapangidwa kuti ikhale yosinthira magawo atatu mumagetsi amagetsi makamaka mtundu wa Z wokhotakhota wa Z ndi zosintha zina zomwe sizikhala ndi katundu wambiri pano.

  • GDB-H Handheld Automatic Transformer Imatembenuza Ratio Tester

    GDB-H Handheld Automatic Transformer Imatembenuza Ratio Tester

    Itha kuyeza molondola chiŵerengero cha kutembenuka, gulu ndi mbali ya gawo, yomwe ili yoyenera kwa mitundu yonse ya thiransifoma monga zosintha zamtundu wa Z, zosinthira zosintha, zosinthira ng'anjo yamagetsi, zosinthira magawo, zosinthira ma traction, ma scott ndi ma invert-scott transfoma.

  • GDB-IV Three Phase Transformer Turns Ratio Tester

    GDB-IV Three Phase Transformer Turns Ratio Tester

    Mphamvu yamkati yamagetsi mu tester imapanga mphamvu ya magawo atatu kapena mphamvu ziwiri, zomwe zimachokera ku mbali yaikulu ya voltage ya transformer.Ndiye voteji mkulu ndi otsika voteji ndi sampuli pa nthawi yomweyo.Pomaliza, gulu, chiŵerengero,cholakwika,ndipo kusiyana kwa magawo kumawerengedwa.

     

     

     

     

     

     

  • GD6900 Capacitance ndi Dissipation Factor Tester

    GD6900 Capacitance ndi Dissipation Factor Tester

    GD6900 imayesa mphamvu ndi dielectric loss factor (tgδ) ya zida zamagetsi zapamwamba kwambiri.Ndi mawonekedwe ophatikizika, mlatho woyeserera wotayika wa dielectric, magetsi osinthika osinthika, owonjezera thiransifoma ndi SF6 capacitor wamba.

     

  • GDZRC Series DC Winding Resistance Tester (GDZRC-10A)

    GDZRC Series DC Winding Resistance Tester (GDZRC-10A)

    GDJRC-10A

    GDJRC mndandanda wa DC wokhotakhota kukana woyesaadapangidwa kuti aziyesa kukana kwa DC kwa inductivezipangizo, monga ma transformer ndi magetsi inductors.
    Ili ndi mawonekedwe a kuyeza mwachangu, kukula kochepandi kuyeza kolondola kwambiri, zomwe ndi zida zoyenerakuyeza mapindikidwe a thiransifoma ndi kukana kwa DC kwazida zazikulu zopangira mphamvu.

     

  • GD6800 Capacitance ndi Dissipation Factor Tester

    GD6800 Capacitance ndi Dissipation Factor Tester

    GD6800 ndindi automatic 10Kuyesa kwa kV insulation power factor/dissipation factor (tan∂).erzakonzedwa kuti ziwunikire momwe magetsi amatenthetsera pamagetsi apamwamba kwambiri monga ma transfoma, ma bushings, ma circuit breakers, zingwe, zomangira mphezi ndi makina ozungulira.

     

     

     

     

  • GDZRS-20A Three Phase DC Winding Resistance Tester

    GDZRS-20A Three Phase DC Winding Resistance Tester

    Choyesa chofulumira cha DC ichi (chomwe chimatchedwa kuti DC winding resistance tester) ndiye chida chaposachedwa kwambiri choyezera kukana kwa DC kwa ma transformer.Imakonzedwa kuti iyeze kukana kwa DC kwa magawo atatu a ma windings a ma transfoma akuluakulu.Kukaniza kwa DC kwa ma windings a magawo atatu a transformer kumatha kuyesedwa nthawi imodzi.Pakuti pa-katundu voteji yoyendetsera thiransifoma, si koyenera kutulutsa chosinthira wapampopi mwachindunji, ndipo nthawi muyeso ndi gawo limodzi mwa magawo atatu a miyambo chikhalidwe gawo limodzi muyeso, amene angafupikitse kwambiri nthawi yogwira ntchito ndi mphamvu ya ntchito.Mamita okanira mwachindunji amatengera chiwonetsero chachikulu chamadzimadzi chamadzimadzi chokhala ndi skrini, mawonekedwe onse aku China, omveka bwino komanso mwachilengedwe, ndipo ntchitoyo ndiyosavuta.Ndipo pokhala ndi chosindikizira chamagulu ndi kukumbukira kwakukulu kosasunthika, mukhoza kusunga ndi kusindikiza zotsatira zake.Zomwe zimayesedwa ndizokhazikika, zachangu komanso zobwerezabwereza, ndipo ndiye chisankho chabwino kwambiri choyezera kukana kwa DC kwa ma transformer pamalopo.

  • GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 ndi chida cholondola kwambiri choyesera ma dielectric loss angle and volume resistivity of insulating oil or other insulating liquids.

  • GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    Pali zida zambiri zamagetsi mumagetsi, njanji ndi migodi yayikulu yamafuta a petrochemical ndi mabizinesi, kutchinjiriza kwawo kwamkati kumakhala kodzaza ndi mafuta.Mphamvu ya dielectric yamafuta otsekera ndikuyesa kovomerezeka.Pofuna kukwaniritsa zosowa za msika, kampani yathu idapanga ndikutulutsa makina oyesa mphamvu yamafuta a dielectric molingana ndi muyezo wadziko lonse wa GB/T507-2002(IEC156), DL429.9-91 komanso mulingo waposachedwa kwambiri wamakampani opanga magetsi. DL/T846.7-2004.Chidachi chimatenga kachipangizo kakang'ono kachipangizo kakang'ono kamene kamayambira, chimazindikira zonse zomwe zimayesedwa, zimakhala zolondola kwambiri, zimathandizira kwambiri magwiridwe antchito, komanso zimachepetsa kwambiri kulimbikira kwa ogwira ntchito.Nthawi yomweyo, chidacho chimakhala ndi mawonekedwe ophatikizika ndipo ndichosavuta kunyamula.

  • GDOT-80A Insulation Mafuta Tester

    GDOT-80A Insulation Mafuta Tester

    Chonde werengani bukuli mosamala musanagwiritse ntchito.
    Chonde onani ngati woyesayo alumikizidwa bwino padziko lapansi musanayese.
    Ndizoletsedwa kusuntha kapena kukweza chivundikiro choyesera poyesa kuti tipewe kuvulazidwa ndi mphamvu zambiri.Mphamvu ziyenera kuzimitsidwa musanalowe m'malo mwa mafuta a zitsanzo.

  • GDKC-5000 Transformer Pa Load Tap Changer Tester

    GDKC-5000 Transformer Pa Load Tap Changer Tester

    GDKC-5000 Transformer On Load Tap Changer Tester imatha kuyeza molondola nthawi yocheperako, mawonekedwe osakhalitsa, kukana kwakanthawi, kulumikizana kwa magawo atatu ndi magawo ena a chosinthira chotsitsa.Ndi chida choyenera kuyesa chosinthira chapampopi.Imakwaniritsa zofunikira pakuwunika kachitidwe kakusintha kwapampopi ndi kuyeza nthawi yosinthira.

     

  • GDBT-1000kVA Transformer Test Bench

    GDBT-1000kVA Transformer Test Bench

    GDBT Transformer test system imatha kuyesa mayeso onse osinthika, kuphatikiza kuyesa kwa No-load and load, kuyesa voteji, kuyesa kwamagetsi, kuyesa kwamagetsi pang'ono, kuyesa kwapang'ono, kuyesa kwa DC kukana, kuyesa kwa chiŵerengero, kukwera kwa kutentha ndi zina.

Titumizireni uthenga wanu:

Lembani uthenga wanu apa ndikutumiza kwa ife