VLF AC Hipot Test Set
Test Test Test ndi njira yofunika kwambiri yodzitetezera pazida zamagetsi.Imagawidwa m'magawo awiri: AC ndi DC kupirira mayeso amagetsi.Mayeso a AC amathanso kugawidwa kukhala ma frequency amphamvu, ma frequency osinthika ndi mayeso otsika kwambiri a 0.1Hz, pomwe omaliza amalimbikitsidwa kwambiri ndi IEC, chifukwa cha zabwino zake.
Zotsatirazi ndi kuyerekezera kwa DC, Mphamvu ya Frequency, Variable Frequency, ndi kuyesa kwa 0.1Hz.
Mbali | DC | Mphamvu pafupipafupi | Kusintha pafupipafupi | 0.1Hz |
Kufanana | osauka | zabwino | zabwino | zabwino |
Kuwonongeka kwa Insulation | wamphamvu | pang'ono | pang'ono | pang'ono |
Chitetezo cha Ntchito | otsika | otsika | otsika | apamwamba |
Kuvuta kwa Wiring | zovuta | zovuta | zovuta kwambiri | zosavuta |
Voliyumu | chochepa kwambiri | chachikulu | chachikulu | yaying'ono |
M'malo mwake kuyesa kwa VLF ndiko m'malo mwa kuyesa pafupipafupi kwamagetsi.Ndizoyenera kuyesa zida zamagetsi zokhala ndi mphamvu yayikulu (monga chingwe chamagetsi, capacitor yamagetsi, mota, ndi jenereta).
Mbadwo watsopano wa VLF mndandanda wa 0.1Hz VLF AC Hipot Test Set wopangidwa ndi HV Hipot utenga "Smart Quick" njira yoyesera mphamvu yanzeru (Soft No. 1010215, nambala yolembetsa chizindikiro 14684781), kampani ya HV HIPOT idayambitsa zida zamakono zapadziko lonse lapansi ukadaulo waposachedwa wa ARM7 microcontroller, ukuchepetsanso kukula ndi kulemera kwa zida.Ntchitoyi ndi yosavuta, ndipo ntchitoyo imakhala yokhazikika.
●Ukadaulo wapamwamba utengera ukadaulo wosinthira pafupipafupi wa digito, kuwongolera kokhazikika kwapakompyuta, kukweza mphamvu, kutsika, kuyeza, chitetezo, ndi zina zambiri.
●Gawo lowongolera ndi gawo la High-voltage litengera kapangidwe kake kaphatikizidwe, ndipo mawaya apamwamba kwambiri ndi waya wapansi amafunikira kuti alumikizane ndi chinthu choyesedwa popanda waya wolumikizira wapakatikati.
●Kapangidwe ka trolley ndi yabwino mayendedwe m'malo osiyanasiyana ogwira ntchito, ndipo kukula kwake kochepa komanso kulemera kwake kumapangitsa kuti pakhale ntchito zakunja (80kV).
●Chitetezo champhamvu kwambiri komanso chitetezo chopitilira pano.Nthawi yochita sikupitilira 10ms.
●Chigawo chowongolera ndi chowonjezera chimalumikizidwa pamagetsi otsika, ndikuwongolera kudzipatula kwa photoelectric, otetezeka komanso odalirika kugwiritsa ntchito.
●Chotsekeka-loop negative feedback circuit imatengedwa.Palibe kuchuluka komwe kumakwera panthawi yotulutsa.
●Capacitive touch screen, LCD graphic display, automatic storage, and printing.
●0.1Hz, 0.05Hz ndi 0.02Hz akhoza kusankhidwa, zomwe zimatsimikizira kuti mayesero osiyanasiyana.
●Mphamvu yapamwamba: 30kV
●Kuchuluka kwa mayeso: 0.1Hz, 0.05Hz ndi 0.02 Hz (zosankhika)
● Maximum load capacity: 1.1μF@0.1Hz / 2.2μF@0.05Hz / 5.5μF@0.02Hz
●Miyezo yolondola: 3%.
●Vuto la nsonga yamagetsi yamagetsi: ≤3%.
●Kusokonekera kwa mawonekedwe amagetsi: ≤5%.
●Malo ogwirira ntchito: m'nyumba kapena kunja;-10 ℃-+40 ℃;85% RH
●Fuse: 8A (30kV)
●Mphamvu yamagetsi: 220V ± 10%, 50Hz ± 5% (Ngati mukugwiritsa ntchito jenereta yonyamula, onetsetsani kuti voteji ndi ma frequency ndi okhazikika. Mphamvu> 3kW, pafupipafupi 50Hz, voteji 220V ± 5%.)
●Mphamvu ya chinthu choyesedwa sichidzapitirira max.oveteredwa capacitance wa chida.