GD6800 Capacitance ndi Dissipation Factor Tester

GD6800 Capacitance ndi Dissipation Factor Tester

Kufotokozera Mwachidule:

GD6800 ndindi automatic 10Kuyesa kwa kV insulation power factor/dissipation factor (tan∂).eradapangidwa kuti aziwunika momwe magetsi amakhalira pamagetsi okwera kwambiri monga ma transfoma, ma bushings, ma circuit breakers, zingwe, zotsekera mphezi ndi makina ozungulira.

 

 


Tsatanetsatane wa Zamalonda

Zogulitsa Tags

GD6800
Mawonekedwe

Large touch screen English chiwonetsero
Kusungirako kwakukulu kwamkati ndikuthandizira U-disk yosungirako
Chitetezo chambiri, chotetezeka komanso chodalirika
Mitundu ingapo yoyesera: UST, GST, GSTg
Mapangidwe opepuka, olimba a chidutswa chimodzi
Mkulu voteji 10kV/200mA (12kV akhoza makonda)
Kuyeza kwa LCR automatic
Kusokoneza kupondereza
Kulondola kwakukulu

Zofotokozera
Mkhalidwe wogwirira ntchito -15 ℃ ~ 40 ℃ RH<80%
Mfundo yotsutsana ndi kusokoneza Kutembenuka pafupipafupi
Magetsi AC 220V ± 10% Jenereta angagwiritsidwe ntchito.
Kutulutsa kwakukulu kwamagetsi 0.5KV ~ 10KV Pafupifupi 0.1 kV
Kulondola 2%
Max.panopa 200mA
Mphamvu 2000 VA
Kudzisangalatsa mphamvu AC 0V~50V/15A 45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Makina apawiri pafupipafupi
Kusamvana tgδ: 0.001% Cx: 0.001pF
Kulondola ∆tgδ: ±(kuwerenga*1.0%+0.040%)
∆C x: ±(kuwerenga*1.0%+1.00PF)
Muyezo osiyanasiyana tg ndi Popanda malire
C x 15pf pa<Cx<300nF
10 kV Cx <60 nf
5 kV pa Cx <150 nf
1 kV pa Cx <300 nf
CVT mayeso Cx <300 nf
Muyezo wa LCR L>20H(2kV) R>10KΩ(2kV)
Kulondola kwa kuyeza kwa LCR 0.1% Kusintha kwa ngodya 0.01
Chiwerengero cha CVT 10-10000
Kulondola kwa chiŵerengero cha CVT 0.1%
Kusintha kwa chiwerengero cha CVT 0.01
Dimension Chigawo chachikulu:470 (L) ×370 (W) ×380 (H)
Bokosi lowonjezera:430 (L) ×350 (W) × 130 (H)
Kukhoza kukumbukira Magulu 200, USB flash disk yosungirako imathandizidwa.
Kulemera Gawo lalikulu: 22.75Kg
Bokosi lowonjezera: 5.25Kg
Standard Chalk
Kunyamula mlandu 1 pc
Mayeso a HV ndi 8m 1 pc
Mayeso a LV amatsogolera 8m 1 pc
Chingwe champhamvu 1.8m 1 pc
CVT Kulumikiza kutsogolo 5m 1 pc
Kutalika kwa 2m 1 pc
Sindikizani pepala 2 mitu
10A fuse 2 ma PC
Buku Logwiritsa Ntchito 1 pc
Lipoti la Mayeso a Factory 1 pc
Zosankha zowonjezera 
Mafuta Oyesera cell 1 pc
Wowongolera kutentha 1 pc

Ndi cell test cell ndi chowongolera chotenthetsera, wogwiritsa ntchito amatha kuyesa tan delta yamadzi a dielectric monga mafuta osinthira.

Heating controller

Wowongolera kutentha

Oil vessel

Chombo cha mafuta


  • Zam'mbuyo:
  • Ena:

  • Titumizireni uthenga wanu:

    Lembani uthenga wanu apa ndikutumiza kwa ife

    Titumizireni uthenga wanu:

    Lembani uthenga wanu apa ndikutumiza kwa ife