GD6900 Capacitance and Dissipation Factor Tester

GD6900 Capacitance and Dissipation Factor Tester

Brief Description:

GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

 


Product Detail

Product Tags

GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

High voltage source is generated by internal inverter of the instrument, which is used for testing test object after transformer boost. If adding a insulation cup and temperature control device, dielectric loss of insulating oil can be tested.

Features

Touch LCD screen display.
Insulation resistance measurement: Built-in insulation resistance test module, can carry out Insulation resistance (IR), absorption ratio (DAR), polarization index (PI) test.
Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
The instrument data can be exported through U disk.
Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
LCR automatic measurement. Inductance, capacitance, resistance, angle can be measured and displayed.
Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.

Specifications
Working condition -15℃~40℃ RH<80%
Anti-interference principle Frequency conversion
Power supply AC 220V±10%, 50/60Hz Generator can be used.
High voltage output AC 0.5KV~10KV (12kV optional) Every 0.1kV
Accuracy 2%
Max. current     200mA
Capacity 2000VA
Self-excitation power AC 0V~50V/15A 50Hz, 60Hz single frequency
45HZ/55HZ  47.5HZ/52.5HZ
55HZ/65HZ  57.5HZ/62.5HZ
Automatic dual frequency
Resolution tgδ: 0.001% Cx: 0.001pF
Accuracy ∆tgδ: ±(reading*1.0%+0.040%)
∆C x: ±(reading*1.0%+1.00PF)
Measurement range tgδ Without limit
C x 15pF < Cx < 300nF
10KV Cx < 60 nF
 5KV Cx < 150 nF
 1KV Cx < 300 nF
CVT test Cx < 300 nF
LCR measurement range L>20H(2kV) R>10KΩ(2kV)
LCR measurement accuracy 0.1% Resolution 0.01
CVT ratio range 10~10000
CVT ratio accuracy 0.1%
CVT ratio resolution 0.01
Insulation resistance DC high voltage 5~10kV Accuracy ±(2%*Reading +10V)
IR accuracy 100kΩ-1000GΩ: <5% (test voltage not less than 250V)
100GΩ-1000GΩ: 10% (test voltage not less than 10000V)
Dimension Main unit: 350(L)×270(W)×270(H)
Accessory box: 350(L)×270(W)×160(H)
Memory capacity 200 groups, USB flash disk storage is supported.
Weight Main unit: 22.75Kg
Accessory box: 5.25Kg
Standard Accessories
Tester 1 set
Accessories case 1 piece
HV red test lead 8m 1 piece
LV black test lead 8m 1 piece
Power cord 1.8m 1 piece
CVT Connecting lead 5m 1 piece
Ground lead 2m 1 piece
Print paper 2 rolls
10A fuse 3 pieces
User's Guide 1 copy
Factory Test report 1 copy
Optional accessories 
Oil Test cell  1 pc   
Heating controller 1 pc

With oil test cell and heating controller, user can test tan delta of dielectric liquid such as transformer oil.

Heating controller

Heating controller

Oil vessel

Oil vessel


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us