GDPD-414 Portable Partial Discharge Detector



Chachikulu
unit
Sensor ya UHF,
mtundu wozungulira,oyenera GIS
Sensa ya UHF, mtundu wa rectangle, yoyenera chingwe chamagetsi, chosinthira, chosinthira



HFCT, yoyenera chingwe chamagetsi, chosinthira
TEV sensor,
oyenera switchgear
Akupanga sensa, oyenera thiransifoma, switchgear

Zithunzi zomwe zili pamwambazi ndizongoyambira.
The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector imagwiritsa ntchito njira yoyesera mphamvu yanzeru yofulumira (Yofewa No. 1010215, nambala yolembetsa chizindikiro 14684781 (14684481)).Ikhoza kusinthasintha sintha masensa osiyanasiyana malinga ndi zinthu zosiyanasiyana kuti ayesedwe.TEV, akupanga ndi HFCT ndi oyenera kuzindikira pang'ono kumaliseche kwa high-voltage switchgear ndi mphete network cabinet;Akupanga ndi UHF ndi oyenera kuzindikira GIS;Akupanga ndi HFCT ndi oyenera kuyesa chingwe chamagetsi.The anamanga-katswiri matenda dongosolo akhoza kusanthula deta mayeso ndi kuweruza kutulutsa mphamvu ndi mbali zotheka.Amagwiritsidwa ntchito kwambiri pamagetsi amagetsi ndi njanji.

Ultrasonic ndi TEV sensor (2-in-1)
●Adopt high-liwiro DSP/FPGA sampling board, 4-channel synchronous data acquisition.
●Pulogalamu yamapulogalamu: pulogalamu yowunikira yotengera dongosolo la ARM lophatikizidwa
●Njira za 6/8/16 zitha kukhazikitsidwa
●8.1 inchi piritsi kapena Thinkpad notebook ngati kusankha
●6/8/16 njira akhoza kukhazikitsidwa malinga ndi zofuna zosiyanasiyana kasitomala.
●Itha kuwonetsa mamapu a PRPS ndi PRPD, zithunzi za ellipse, mamapu otulutsa, mamapu a QT, mamapu a NT, mamapu ophatikizika a PRPD, mamapu a fai-QN amtundu uliwonse wamakina.
● Mitundu yamitundu itatu yofiira, yachikasu ndi buluu imawonetsa kuopsa kwa kutulutsa pang'ono.
Makasitomala amatha kusankha masensa molingana ndi zinthu zosiyanasiyana zoyesedwa:
Zomverera | TEV/AE/Mtengo wa HFCT | AE/UHF | AE/Mtengo wa HFCT |
Zinthu Zoyesedwa | HV Swichgear ndi Ring network cabinet |
GIS |
Chingwe |
PD chizindikiro kupeza host host | |
CPU ntchito pafupipafupi | 1.2GHz / 800MHz |
Opareting'i sisitimu | Linx ophatikizidwa opaleshoni dongosolo |
Wired network port | LAN network port |
Wireless network port | WiFi yopanda zingwe yomangidwira (posankha) |
Kukumbukira kwadongosolo | 1G / 512M |
Memory yosungirako dongosolo | 512M / 256M |
Kuchuluka kwa data | 250MHz / 80MHz |
Akupanga njira yodziwira | |
Muyezo osiyanasiyana | 0-60mV |
Kuzindikira pafupipafupi | 20-200 kHz |
Njira yodziwira UHF | |
Kuzindikira pafupipafupi | 300 ~ 1800MHz / 300 ~ 1500MHz |
Muyezo osiyanasiyana | -80 ~ 10dBm |
Cholakwika | ± 1dBm |
Kusamvana | 1dbm pa |
Njira yodziwira ya HFCT | |
Nthawi zambiri | 0.5 ~ 100MHz |
Cholakwika | ±1dB |
Dynamic Range | 60db pa |
Muyezo osiyanasiyana | 0-100mV |
Kulondola | 1dB pa |
Njira yodziwira TEV | |
Nthawi zambiri | 3 ~ 100MHz |
Cholakwika | ± 1dB / mV |
Kumverera | 0.01mV |
Muyezo osiyanasiyana | 0-60dB / mV |
Kusamvana | 1dBm/mv |
Batiri | |
Batire yomangidwa | Lithium batire, 12V, 4400mAh / Lithium batire, 12V, 2000mAh |
Gwiritsani ntchito nthawi | pafupifupi 8 hours / pafupifupi 6 hours |
Nthawi yolipira | Pafupifupi 2 hours |
Chitetezo cha batri | Kutetezedwa kopitilira muyeso komanso kupitilira apo |
Kuthamanga kwa batri | |
Adavotera mphamvu | 12.6 V |
Kulipiritsa linanena bungwe panopa | 2A |
Kutentha kwa ntchito | -20 ℃-60 ℃ |
Chinyezi chogwira ntchito | <80% |
GDPD-414H Handheld display terminal (giredi la mafakitale) | |
CPU | Intel Quad Core Atom Z3735F |
GPU | Zithunzi za Intel HD (Gen7) |
Kung'anima | 32 GB |
Ram | 2GB pa |
Opareting'i sisitimu | Windows 10 |
Onetsani | 8.1 inchi 1280 × 800 IPS chophimba |
Network mawonekedwe | Wifi ndi Bluetooth |
Batiri | 3.7V 8500mAH polima lithiamu ion batire |
Thinkpad Laputopu kapena Tablet PC | |
Kukula | |
Kukula kwamilandu yowonjezera / kukula kwa PD kupeza | 395mm * 295mm * 105mm / 240mm * 165mm * 55mm |
PD Host kulemera | 3kg / 0.65kg |
PD hose kesi size / Onetsani kukula kwa piritsi | 570mm * 360mm * 240mm / 395mm * 295mm * 105mm |
Onetsani kulemera kwa piritsi | 0.85kg |
Kukula kwa bokosi lonse | 570mm*360mm*240mm |
Malo ogwirira ntchito | |
Kutentha kwa ntchito | -20 ℃ ~ 50 ℃ |
Chinyezi cha chilengedwe | 0-90% RH |
IP mlingo | 54 |
GDPD-414H Chojambulira Pamanja Chotulutsa Pamanja