GDPD-414 Portable Partial Discharge Detector
GDPD-414 Portable Partial Discharge Detector imagwiritsa ntchito njira yoyesera mphamvu ya Smart Quick, ndipo ndi chida chonyamulika chapanyumba chowunikira zida zamagetsi zamphamvu kwambiri.
-
GD-610C Remote Ultrasonic Partial Discharge Detector
GD-610C kutali akupanga tsankho kumaliseche chodziwira ntchito akupanga sipekitiramu kafukufuku (sensor) kusonkhanitsa akupanga zizindikiro ndi kusanthula phokoso zizindikiro kuzindikira zolakwika, ndi matenda chipangizo ngozi ya mzere kugawa.
-
Pang'ono Kutulutsa Paintaneti Monitoring System ya GIS
Ma switch otsekedwa ndi zitsulo zotsekedwa ndi gasi (GIS) ndi mizere yotumizira zitsulo zotsekedwa ndi gasi (GIL) ndi imodzi mwa zipangizo zofunika kwambiri pamagetsi.Iwo ali ndi ntchito ziwiri za ulamuliro ndi chitetezo.
-
Njira Yowunikira Mwapang'ono Paintaneti ya Majenereta
Nthawi zambiri, kutulutsa pang'ono kumachitika pamalo pomwe zida za dielectric sizili zofanana.
-
GDJF-2006 Partial Discharge Analyzer
GDJF-2006 Digital Partial Discharge Detector imagwiritsidwa ntchito kwambiri pozindikira kutulutsa kwapang'onopang'ono kwa zida zamagetsi apamwamba monga zosinthira mphamvu, chosinthira zida, HV circuit breaker, Zinc oxide surge arrester, chingwe chamagetsi.Ithanso kupanga mayeso amtundu ndikuyang'anira ntchito yotsekera.
-
GDJF-2007 Digital Partial Discharge Analyzer
GDJF-2007 Digital Partial Discharge Analyzer imagwiritsidwa ntchito kwambiri pozindikira kutulutsa kwapang'onopang'ono kwa zida zamagetsi apamwamba monga ma transfoma amphamvu, chosinthira zida, HV circuit breaker, GIS, Zinc oxide surge arrester, chingwe chamagetsi.
-
GDJF-2008 Partial Discharge Analyzer
GDJF-2008 Partial Discharge Detector ikuyesa kutulutsa pang'ono kwa zinthu monga zosinthira, ma inductors, masiwichi a HV, zomangira zinki monoxide ndi zingwe zamagetsi.Ithanso kupanga mayeso amtundu ndikuyang'anira ntchito yotsekera.
-
GDPD-414H Chojambulira Pamanja Chotulutsa Pamanja
The GDPD-414H handheld Partial Discharge Detector imagwiritsa ntchito njira yoyesera mphamvu yanzeru mwachangu (Soft No. 1010215, nambala yolembera chizindikiro 14684481), yomwe imatha kusinthira masensa osiyanasiyana molingana ndi zinthu zosiyanasiyana zoyesa.
-
GDPD-306M Portable Ultrasonic Partial Discharge Detector
GDPD-306M imagwiritsidwa ntchito kwambiri pozindikira kutulutsa pang'ono kwamagetsi.Kuphatikizira ma switchgear okwera kwambiri, ma ring mains, voltage/transformer yapano, thiransifoma (kuphatikiza chosinthira chamtundu wouma), GIS, mizere yakumtunda, zingwe, ndi zida zina zodziwikiratu.
-
GDPD-313M Portable Partial Discharge Detector
Njira ya TEV ndi AE ndiyovomerezeka komanso ukadaulo woyenera kuti ugwiritsidwe ntchito pozindikira kutulutsa pang'ono pa intaneti.
-
GDPD-3000C Portable Partial Discharge Detector
GDPD-3000C Portable Ultrasonic Partial Discharge Detector imagwiritsa ntchito makina apamwamba kwambiri a mtambo ndi ukadaulo wodziyimira pawokha kuti akwaniritse kuyeza kwapang'ono, kujambula, kutumiza, kusungirako, kusanthula ndi kusinthanitsa, kupereka chithandizo champhamvu chaukadaulo pakuyezera kwapayekha kutulutsa pang'ono.