Partial Discharge Test System GIT mndandanda

Partial Discharge Test System GIT mndandanda

Kufotokozera Mwachidule:

GIT mndandanda chimagwiritsidwa ntchito voteji mkulu, mphamvu GIS zida insulated kupirira voteji mayeso, tsankho kumaliseche mayeso ndi GIS thiransifoma kulondola mayeso, oyenera GIS substation, GIS mphamvu zida wopanga, beseni mtundu magetsi insulator Mlengi.

 

 

 

 

 


Tsatanetsatane wa Zamalonda

Zogulitsa Tags

GIT Series GIS High Voltage Test Sets imaphatikiza kukwezera voteji, kuyeza kwamagetsi apamwamba, chosinthira voteji, ma capacitor ophatikiza ma voltage ndi zonse zomwe zili pamalo osindikizidwa.
Pali njira ziwiri zopangira voteji
1) Kugwiritsa ntchito riyakitala inductance ndi kuyesa chinthu capacitance kuzindikira voteji resonance mayeso, kupeza voteji mkulu, mkulu panopa kuchokera mayeso chinthu.
2) Chinacho ndikupeza voteji yokwera kwambiri kuchokera ku transformer yokwera kwambiri.

Amagwiritsidwa ntchito kwambiri voteji mkulu mphamvu GIS zida mphamvu insulated kupirira voteji mayeso, tsankho kumaliseche mayeso ndi GIS thiransifoma kulondola mayeso, oyenera GIS substation, GIS mphamvu zida wopanga, beseni mtundu magetsi insulator wopanga.

Electrical testing equipment
High voltage measurement
Mawonekedwe

Magetsi apamwamba omwe amapezeka amasindikizidwa bwino komanso otetezedwa m'mitsuko, amateteza chitetezo cha munthu, palibe kusokoneza kunja.
Kuyeza kolondola.
Ngati muwonjezera mawonekedwe amagetsi apamwamba kwambiri, zitha kupangitsa kuti magetsi azikwera kwambiri, zomwe zimatha kuyesa mitundu yosiyanasiyana yamagetsi pazida zachikhalidwe zapamwamba.
Mtundu wotetezeka kwambiri wamayezedwe apamwamba kwambiri.

Partial discharge test
pd test of transformer
Zofotokozera

Mphamvu yamagetsi: 100kV, 200kV, 250kV, 300kV, 500kV, 750kV, 1000kV, kutengera zinthu zosiyanasiyana zoyesa.
Mphamvu: 50-2000kVA, kutengera zinthu zosiyanasiyana zoyesa.
High voteji kwaiye mode: mkulu voteji thiransifoma voteji kulimbikitsa ndi mndandanda resonance (mphamvu pafupipafupi, pafupipafupi kutembenuka).
Njira zonse zowonjezerera voteji ndi gawo limodzi la voteji, palibe chifukwa chotsitsa voteji.
Mphamvu yamagetsi: 0.35-10kV.
Kutulutsa pang'ono: Kuvotera voteji 3pc (malo abwinobwino).
Mphamvu yamagetsi: 5%.
Kutentha kwa kutentha: osapitirira 65k(50Hz) pamene oveteredwa panopa ntchito 60mins.