GD-4138H Cable Fault Locating System
GD-4138H Mobile Cable Fault Locating System ndi chida chofunikira posungira mitundu yonse ya zingwe.Ndi zida zogwirizana zomwe zimatha kutsata, kupeza zingwe zapansi panthaka, zokhala ndi mtunda wolakwika komanso kutulutsa kwa HV.Popeza ndi chipangizo chosunthika, ndi yabwino kunyamula pa malo.Ngati ma acoustic locator agwiritsidwa ntchito limodzi, amatha kupeza pomwe pali chingwe cholakwika.
Ntchito ndi mobisa chingwe, mlengalenga chingwe, chingwe mphamvu, chingwe m'deralo, chingwe kulankhula ndi CHIKWANGWANI chingwe.
●High impedance flash-over vuto
●Kutaya kwakukulu kwa impedance
●Kukhazikika kwapamwamba/kutsika kolimba
●Kuwonongeka kwafupipafupi
●Vuto lotseguka
●Kusalumikizana bwino / Kutha
●GD-4138H chimango chachikulu (Cholumikizira chipangizo, Sphere kusiyana, HV jenereta mkati)
●GD-4133 Multiple pulse cable fault tester
●GD-4132 Cable Fault Locator
●Njira zingapo zoyambira: njira yotsika-voltage pulse, njira yapano ya pulse, njira zingapo zosinthira: zitsanzo zamakono, zotulutsa za DC.
●Mitundu yazizindikiro zachitsanzo: Njira yowonetsera DC arc, zitsanzo zamakono, zitsanzo zamagetsi, kutsika kwamagetsi.
●Pezani mwachangu ndikulozera zolakwika zotsika, zolimba kwambiri zotayikira ndi zolakwika za flashover zamitundu yosiyanasiyana ya 220V ~ 220KV voltage grade grade.
●Palibe chifukwa chochitiramawaya ovuta poyesa pa malo.Mitundu yonse yoyesera imasinthidwa zokha kudzera pa switch yamkati yamagetsi yamagetsi yoyendetsedwa ndi mphamvu yofooka.
●Integrated multi-speed DC high-voltage jenereta, multi-speed high-voltage capacitor, arc stabilizing unit ndi kupeza zizindikiro zosiyanasiyana mu imodzi, yosavuta kugwiritsa ntchito malo olakwika.
●Mipikisano-level linanena bungwe mkulu voteji kusintha, onse olamulidwa ndi otsika voteji wamkati ofooka panopa, otetezeka ndi odalirika.
●Mapangidwe a zidazo amatengera pulasitiki yamphamvu kwambiri.Mlanduwu ndi bokosi lakunja la zida ndi bokosi losamutsa la phukusi loperekera zida.Ndikwabwino kusamutsa, ndipo imatha kukwezedwa ndikusamutsidwa mwachindunji chivundikirocho chatsekedwa.
●Sphere gap impulse discharge: Kuchepa kwamphamvu kwamphamvu kwa solenoid valve air gap, nthawi yotulutsa imatha kusinthika kuchokera ku 3 mpaka masekondi a 12, ndipo chotchingiracho chimapangidwa mwapadera kuti chikwaniritse zofunikira za kusalankhula kwa kulephera kwa chingwe poyambira.
●Zipangizozi zili ndi gawo lopangira zotulutsa.Pambuyo poyesa zolakwika, magetsi okwera amatha kuzimitsidwa ingodinani batani pamalo otulutsa kuti mungotulutsa zokha.
●Malo oyezera mtunda amatha kupereka chigamulo choyezera mtunda mpaka 0.4m, ndipo malo akhungu oyezera ndi ang'onoang'ono, omwe ndi othandiza makamaka ku zolakwika zapafupi ndi zingwe zazifupi.
●Magawo onse opangira zida amakonzedwa pagawo lakumbuyo kuti ma waya osavuta, ndipo zithunzi zama waya za njira zosiyanasiyana zama waya zimakokedwa pagawo la opaleshoni, lomwe lingagwiritsidwe ntchito mosavuta ndi anthu opanda chidziwitso.
●Pansi pa zidazo zimakhala ndi mawilo 4 othamanga kwambiri, omwe amatha kukankhidwa ndikusungidwa kuti asungidwe.
●Wolandirayo amagwiritsa ntchito LCD ya 7-inch yayikulu yokhala ndi ngodya yowonera 160 °, ndipo zowonetsera ndizolemera komanso zowoneka bwino.
●Ma waveform ambiri amatha kusungidwa m'menemo, ndipo deta ya waveform imatha kutumizidwa kunja ndikutumizidwa kunja pogwiritsa ntchito U disk.
●Wothandizirayo atha kulumikizidwa ku kompyuta (desktop kapena notebook) kuti azitha kulumikizana pa intaneti.
●Pamene wolandirayo alibe ntchito mkati mwa mphindi za 2, kuwala kwambuyo kudzafooka;ngati palibe opareshoni kwa mphindi 10, imangotseka kuti ichepetse kugwiritsa ntchito mphamvu;pamene batire ndi undervoltage, chida adzakhalanso basi basi kuteteza batire.
●Wolandirayo ali ndi batire ya lithiamu-ion yopangidwa ndi polima ndipo ili ndi charger yodzipereka ya lithiamu kuti ipereke njira yodalirika yolipirira.
●Makina onse amatengera kapangidwe kake kabokosi kosinthira, komwe kumakhala kocheperako komanso kolimba, koyenera kugwiritsa ntchito malo omanga.
| Chitsanzo | Chithunzi cha GD-4138L | GD-4138M | GD-4138H |
| Njira yoyesera | Njira yowonetsera Arc, zitsanzo zamakono, zotulutsa za DC | Njira yowonetsera Arc, njira yowonetsera DC arc, zitsanzo zamakono, zotulutsa za DC | |
| Mtundu wa chizindikiro cha zitsanzo | Multiple pulse arc reflection njira, zitsanzo zamakono, low voltage pulse | Njira yowonetsera Arc, njira yowonetsera DC arc, zitsanzo zamakono, zotulutsa za DC | |
| Kutulutsa kwa DC HV | 0 ~ 16KV polarity negative Kutulutsa kwakukulu kwaposachedwa: 152mA | 0 ~ 32KV negative polarity Kutulutsa kwakukulu kwaposachedwa: 76mA | 0 ~ 8KV negative polarity Maximum linanena bungwe panopa: 304mA 0 ~ 16KVnegative polarity Maximum linanena bungwe panopa: 152mA 0 ~ 32KVnegative polarity Maximum linanena bungwe panopa: 76mA |
| Mphamvu ya Flashover | 0-16kV 8μF Kuchuluka kwa mphamvu: 1024J | 0-32kV 4μF Kuchuluka kwa mphamvu: 2048J | 0-8kV 32μF Kuchuluka kwa mphamvu: 1024J 0-16kV 8μF Kuchuluka kwa mphamvu: 1024J 0-32kV 4μF Kuchuluka kwa mphamvu: 2048J |
| Kutulutsa kwapakati pazigawo | Ofooka panopa ulamuliro solenoid valavu mpweya kusiyana, nthawi kukhetsedwa ndi chosinthika kuchokera 3 mpaka 12 masekondi, ndi muffler ndi mwapadera kuti akwaniritse zofunika osalankhula kwa chingwe kulephera pa chiyambi. | ||
| Zotulutsa | DC imapirira magetsi, kutulutsa kamodzi, kutulutsa nthawi ndi nthawi | ||
| DC imalimbana ndi magetsi | 16 kV | 32 kV | 32 kV |
| Voltage yovomerezeka yolowera | 16kv ku | 32 kv | 32 kv |
| Mphamvu zololeka zotengera mphamvu | <2048J | ||
| Malo ogwirira ntchito | Kutentha: 0 ~ 40 ℃ Chinyezi chachibale: <75%RH | ||
| Magetsi | AC220V, 50Hz | ||
| Kukwanira kwathunthu | 3 kVA pa | ||
Amagwiritsidwa ntchito kuyeza mtunda wolakwika.Pansi pa LV pulse mode, itha kugwiritsidwa ntchito yokha.
7inch LCD chophimba, wochezeka mawonekedwe.
Njira zingapo zopezera mtunda:
Njira yotsika yamagetsi: ndiyoyenera kupeza cholakwika chochepa, cholakwika chachifupi, cholakwika chotseguka.Itha kugwiritsidwanso ntchito pakuyezera kutalika kwa chingwe, zolumikizira zapakatikati, zolumikizira za T, ndi kulumikizana kwa chingwe.Njirayi ingagwiritsidwenso ntchito kukonza liwiro la mafunde.
Njira yaposachedwa ya Pulse: Ndi yoyenera kuyeza mtunda wa vuto lalikulu la kukana, vuto losweka.Kugwiritsa ntchito coupler yapano kusonkhanitsa ma sign kuchokera ku waya wapadziko lapansi, kumapangitsa wosuta kukhala kutali ndi voteji yayikulu.Njirayi ndi yotetezeka komanso yodalirika.
Multiple pulse: njira yapamwamba yoyezera mtunda.Ma waveform ndi osavuta kuzindikira ndipo kulondola kwake ndikwambiri.
200MHz zitsanzo zenizeni zenizeni.Max.0.4m kutalika kwa miyeso.Ili ndi zone yaing'ono yakufa ndipo ndi yapadera pa chingwe chachifupi komanso pafupi ndi chingwe cha fault.
Kukhudza screen ndi kukanikiza makiyi ntchito.Cholozeracho chikhoza kukokedwa.
Kope la PIP(chithunzi. kusungidwa kwakanthawi)
Padzakhala zenera lalikulu ndipo mazenera atatu osungira osakhalitsa amatha kuyang'ana ma waveform atatu palimodzi.
Makina opangira ophatikizidwa
Kuwongolera kwapadera kwa mapulogalamu okweza mapulogalamu, kusunga ndi kubwezeretsa.
Sikelo ntchito
Malo amodzi oyambira, ma contact 10, vuto limodzi la chingwe ndi utali wonse akhoza kukhazikitsidwa.
Onetsani kukula ndi kuyesa mawonekedwe a waveform nthawi imodzi
Kusungirako kwa Waveform ndi kulumikizana ndi kompyuta.
Kusungirako kwamkati kwa ma waveforms.
Ndi USB, kutsitsa kapena kukweza deta
Kulumikizana ndi kompyuta
Kuwongolera mphamvu
Kuwala kwambuyo kumachepa ngati palibe ntchito mu 2mins ndikuzimitsa mu 10mins ngati palibe ntchito.
Batire yomangidwa mu Polymer Lithium-ion.
Nthawi yogwira ntchito ndi maola 5 pakugwiritsa ntchito kulikonse.
Mlandu wamphamvu, wosavuta kunyamula.
| Njira zopezera | Njira yotsika mphamvu yamagetsi Impulse njira yokha Njira zambiri zokakamiza |
| Max.Zitsanzo pafupipafupi | 200MHz |
| Kupeza osiyanasiyana | 0-70dB |
| Low voltage impulse voltage | 30 v |
| Max.kusamvana | 0.4m |
| Max.Malo osiyanasiyana | 100km |
| Dead zone | 2m |
| Batiri | Nickel-metal hydride rechargeable mabatire, kupirira nthawi yopitilira maola 5 |
| Kulankhulana mawonekedwe | USB |
| Magetsi | Lowetsani AC220V, 50Hz, 2A yapano, kulipira maola 8 |
| Dim. | 274 × 218 × 81mm |
| Kulemera | 3.5kg |
| Kutentha kwa Ntchito | -10 ℃-40 ℃ |
| Chinyezi | 5-90%RH |
| Kukwera | <4500m |
●Acoustic ndi maginito chizindikiro amalandiridwa nthawi yomweyo.Mphamvu zotsutsana ndi kusokoneza.
●Chiwonetsero cha Waveform.
●Acoustic maginito waveform chiwonetsero.
●Kupeza malo olakwika ndikutsata njira.
●Ndi m'makutu kumva phokoso.
●320 * 240 LCD chiwonetsero chazithunzi, mawonekedwe ochezeka.
●Batire yomangidwa mkati ya Li, yokhala ndi charger yothamanga.
●Izimitsa yokha ngati sikugwira ntchito pakatha mphindi 15 kapena batire yotsika.
●Kukula kochepa, kosavuta kunyamula.
●Acoustic sign bandwidth: pakati pafupipafupi 400Hz, bandwidth 200Hz
●Kupindula kwa Signal: 80db.
●Malo olondola: 0.1m
●Mphamvu yamagetsi: batire ya Li yomangidwa, voliyumu yodziwika 7.4V, 3000mAh, 9hours yogwira ntchito mosalekeza.
●Chaja: Lowetsani AC220V±10%, 50Hz, kutulutsa mwadzina 8.4V, DC1A
●Nthawi yolipira: <4 hours
●kukula: 270 * 150 * 210mm.
●Kulemera kwake: 1.5kg.
●Ntchito chikhalidwe: kutentha -10--40 ℃, chinyezi 5-90% RH, okwera <4500m.