Pakati pa Marichi, kasitomala ku Beijing adalumikizana ndi kampani yathu pafoni kuti afunse za mtengo wa "transformer bushing localized on-line monitoring system".Pambuyo poyankhulana pakati pa woyang'anira malonda a dera ndi injiniya wamkulu waukadaulo ndi kasitomala, zinthu zonse zofunika ndi magawo oyenera zidatsimikizika m'masiku a 2 okha, ndipo maphwando awiriwa adasaina mgwirizano wogwirizana.
HV Hipot GDPD-BR-OL Transformer Bushing PD Online Monitoring System
The transformer PD on-line monitoring system ndi yoyenera kuyang'anira pa intaneti komanso osagwiritsa ntchito intaneti pakutulutsa pang'ono kwa mabatani a transformer okhala ndi ma voltage a 110kV ndi kupitilira apo.Transformer bushing partial discharge online monitoring system yomwe imapangidwa pophatikiza ukadaulo wa digito ndi ukadaulo wa zida zomwe zimagwiritsidwa ntchito poyang'anira ma thiransifoma a 110KV ndi kupitilira apo, ndipo zimatha kusunga mawonekedwe oyeserera a gawo lililonse la thiransifoma bushing ndikuwunika zomwe zikuchitika, kuti kuti munthawi yake Pezani zolakwika zotchingira za thiransifoma bushing, ndikupereka muyezo wowunikira mulingo wa kutchinjiriza ndi digiri ya ukalamba, ndikupereka maziko a ntchito yokonza thiransifoma.
The osachepera muyeso kutulutsa matalikidwe a dongosolo lino: 20mV (pa-malo), osiyanasiyana pafupipafupi ndi 200kHz ~ 300MHz, nthawi kusamvana kwa kutulutsa kugunda ndi 10μs, ndi kusamvana gawo ndi 0,18 °.
Dongosololi limapereka chithunzi cha 50 chotulutsa mphamvu pafupipafupi, mawonekedwe awiri (q-φ, N-φ, Nq), mawonekedwe atatu (Nq-φ), omwe angagwiritsidwe ntchito kusanthula mtundu wa kutulutsa.
Dongosolo lopangidwa ndi MySQL limatha kujambula magawo oyezera, kuchuluka kwa kutulutsa, gawo lotulutsa, nthawi yoyezera ndi zina zofananira.
Komanso magawo a zida monga thiransifoma bushing model, malo oyezera, ndi zina zambiri, imatha kupereka ma graph omwe amatuluka komanso kukhala ndi machenjezo oyambira ndi ma alarm, ndipo imatha kufunsa, kufufuta, ndikusunga nkhokwe.
Dongosololi limagwiritsa ntchito njira zotsutsana ndi zosokoneza monga kusefa kwa digito ndikukhazikitsa ziwopsezo zosunthika, ndipo zoyeserera ndizowona komanso zodalirika.
Kukhutira kwamakasitomala ndiye mphamvu yathu yoyendetsera!M'tsogolomu, HV Hipot sidzaiwala cholinga chake choyambirira, kupititsa patsogolo, ndikugwira ntchito ndi makasitomala atsopano ndi akale kuti apereke zida ndi ntchito zabwino zamagetsi ndikuthandizira mphamvu zamagetsi kuti ziziyenda bwino.
Nthawi yotumiza: Mar-24-2022