GDBT-8610P Battery Impedance Tester
GDBT-8610P Battery Tester imagwiritsidwa ntchito kwambiri m'magawo awa:
● Telecom: Central Office, malo opangira deta ndi Masamba Akutali
● Mphamvu Zogwiritsira Ntchito: Switchgear, Power Station ndi Power Plant
●Mabungwe azandalama: Corporate Data Centers
● Petrochemical: Njira Zowongolera Njira
● Mapulatifomu akunyanja
● Boma: M’madera ndi m’madera
● Malo Opangira Misonkho ndi Ndalama
● Homeland Security, Schools, Army and Navy
●Maofesi a Air Force, Ozimitsa Moto ndi Apolisi
●Chipatala cha UPS
● Ogulitsa magalimoto amagetsi
● SLA amapanga batire
● Kuyesa kwakukulu: 5 ~ 6000Ah, yogwirizana ndi selo imodzi ya 1.2V, 2V, 6V ndi 12V
●Chida chanzeru komanso chonyamula pamanja, cholimba komanso chosavuta kugwiritsa ntchito
● Chojambula chojambula chokongola chokhala ndi ma kiyibodi osasankha
● Yesani nthawi yomweyo mphamvu yamagetsi, kukana komanso kuchuluka kwa mabatire
● Kuyeza kwa intaneti, palibe chifukwa chochotsera batri ndi chingwe ku dongosolo lake kuti ayesedwe, otetezeka komanso osavuta
●Kuyesa mwachangu batire ndi zingwe m'masekondi ndi kuyesa kupulumutsa paokha
● Kutsutsana kwamphamvu kwamphamvu pamakono apamwamba ndi ntchito yokhazikika komanso yolondola
● Kuyesa kwafupipafupi kutsika kuposa 10 Hz, kupeweratu kusokonezedwa ndi capacitive resistance ya batri palokha
● USB drive yolunjika yosinthira mapulogalamu ndi kusamutsa deta ku PC kuti muwunikenso
● Mapulogalamu amphamvu a PC oyang'anira, osavuta kusunga ndi kusanthula
●Kukumbukira kwakukulu poyesa kusungirako deta yamaselo oposa 3000
● Ntchito ya Alamu ya Buzzer ndi chitetezo chamagetsi opitilira magetsi, otetezeka kugwiritsa ntchito
●Auto-calibration ntchito isanayesedwe, kukulitsa kulondola kwa kuyesa
●Kuyesanso ndi kubwezera: ntchito iliyonse yolakwika kapena yosiya ikhoza kuyesedwanso ndikungodina kamodzi
● Deta yolozera mkati mwa kukumbukira kuti mufananize mayeso anu, ndi ziwerengero zodziwonetsera nokha zilipo
Kukana osiyanasiyana | 0.00mΩ ~ 100mΩ | Mtundu wamagetsi | 0.000V ~ 16V* |
Min test resolution-Voteji -kukana
| 1 mv 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ(0.01mΩ) 10-99mΩ: 100 μΩ (0.1mΩ) | Mayeso olondola -voltage -kukana
| ± 0.2%rdg ± 6dgt 0μΩ-250μΩ: 8%±6DGT 250μΩ-500μΩ: 3%±6DGT 500μΩ-100mΩ: 1%±6DGT |
Magetsi | 7.2V 2400mAhBatire ya Li-ion | Nthawi yogwira ntchito | Kupitilira maola 5 mutalipira kwathunthu |
Kuyeza kukumbukira kwa data | 3000 ma cell | Malo ogwirira ntchito | 0 ℃ mpaka 40 ℃90% RH |
Chiwonetsero cha LCD | 320 * 240 pixel TFT touch screen | Dimension(main unit) | L210*W110*H60 mm |
Kalemeredwe kake konse(paketi) | 2 kg | Com port | Mini USB |