GDCF-900T Galimoto Yokwera Chingwe Cholakwika Chopeza Dongosolo
Dongosolo la Vehicle Mounted Cable Fault Locator System limagwiritsidwa ntchito pokonza Cable Fault (kuwotcha), Pre-Location, Location, Route Location, Pin-pointing & Testing of HV & LV zingwe zamitundu&makulidwe osiyanasiyana.Akonzedwa ndi oyenera kuchita tatchulazi multifunction pa zingwe mphamvu zosiyanasiyana voteji misinkhu makamaka 33KV, 11KV, 415V ndi zingwe ulamuliro ndi 1.1 KV kalasi.Setiyi idzagwiritsidwa ntchito pamitundu yama chingwe monga XLPE, PVC, PILC yokhala ndi woyendetsa Al / Cu.Zingwezo zimayikidwa mobisa (pansi pa nthaka yosalala, ngalande, kapena RCC pamwamba, Kubowola kopingasa mu HDD Pipe), pamwamba pa nthaka kapena pang'ono pansi & pang'ono pamwamba pa nthaka ndi kutalika kwa chingwe mozungulira 25Km.
Chowotcha chingwe ndi choyenera kupeza zolakwika ndikulozera mitundu yotsatira ya zolakwika za chingwe.
●Kukana kwakukulu
●Kukana kochepa
●Kuwonongeka kwamtundu wapakatikati.
●Malo a Sheath Fault
●Dongosololi limagwiritsa ntchito ma pulses angapo (njira yowonetsera ARC), ma pulses katatu, njira yopumira, njira ya flashover, njira ya TDR yoyesera movutikira mitundu yonse ya zolakwika za chingwe.
●Imagwiritsa ntchito njira ya maginito kuti ipeze zolakwika.
●Imagwiritsa ntchito mfundo yoyendetsera ma elekitirodi kutsata chingwe chosadziwika ndikupeza kuya kwa chingwe.
●Dziwani ndikuboola zingwe.
●Pezani ndi kuyeza chingwe sheath.
Makina oyeserera amagetsi okwera pamagalimoto amagwiritsa ntchito dongosolo lokhazikika komanso laumunthu kuti apeze vuto lalikulu la 33KV, 11KV ndi 415V zingwe zamagetsi, kuzindikira komwe kuli kolakwika kwa sheath yakunja, malo otsimikizira, kuyesa njira, chizindikiritso chamoyo, kuphulika kwachitetezo. , DC kukana kuti mitundu yonse ya zida zoyesera, zida zogawira mphamvu, zowonjezera ndi zida zothandizira zimayikidwa pamagalimoto apadera osinthidwa.
Njira yonse yoyeserera ndi yotetezeka komanso yotsekedwa, ndipo ntchito zoyeserera ndizosiyanasiyana ndipo zotsatira zake ndi zolondola.
●Galimotoyo ili ndi magawo atatu: cab, chipinda chopangira opaleshoni ndi chipinda cha zida.
●Kapangidwe ka opareshoni konsoli ndi koyenera, ndipo kuyesa kutsekereza chingwe, kuweruza kolakwika kwa katundu, ndi kuyeza molakwika kwa mtunda kumatha kumalizidwa kwathunthu mgalimoto.
●Woyeserera woyeserera amatha kumaliza kuyeza movutikira kwa mtunda wa fault point ndipo atha kumangirira malowo.
●Chipinda chowongolera chimapangidwa ndi gawo lodziyimira pawokha lamphamvu kwambiri, LCD imawonetsa zenizeni zenizeni komanso magetsi, molunjika mwanzeru ntchito yamagetsi apamwamba kwambiri komanso kutulutsa.
●Chizindikiritso cha chingwe, njira yoyeserera imayikidwa muchipinda chopangira opaleshoni.
●Gome la opareshoni limapangidwa ndi utomoni wa epoxy kuti ukhale wabwino komanso wokongola.Chojambuliracho chidapangidwa ndi kupanga zitsulo komanso maloko omvera njanji.Ndi yolimba, yosagwedezeka, yosavala komanso yosavuta kupukuta.Zimatsimikizira chitetezo cha njira yoyesera.
Mapangidwe amkati
1——Malo oyendetsera galimoto
2——Malo ogwirira ntchito
3--Chigawo chowongolera chapakati
4——Kukonza chizindikiro cholakwa
5——Chida choyezera galimoto
6—— High-voltage test unit
7——Chitetezo
8——Jenereta
9—— High Voltage Test cable reel
10——Chingwe chapansi
11——Khoma lodzipatula
Dongosolo lonse limaphatikizapo
Kanthu | Dzina | Chitsanzo No. | Qty |
1 | Vehicle | -------------- | 1 |
2 | Multi-pulse cable fault tester | GD-4133 | 1 |
3 | Pulse coupler
| GD-4133S
| 1 |
4 | Cwodziwa zolakwika
| GD-4132
| 1 |
5 | Hjenereta yamphamvu yamagetsi | GD-2131H
| 1 |
6 | Cchizindikiritso chokhoza | Zithunzi za GD-2134D
| 1 |
7 | Cchipangizo chokhoza kubowola | GD-2135B | 1 |
GD-2131H Impulse Generator
Imagwiritsidwa ntchito popanga chikoka cha HV mukamagwiritsa ntchito njira yopumira ya flashover kuti muwone vuto lalikulu.
●Kukhoza kuyaka mwamphamvu, max.mphamvu yoyaka ndi 1000W, malo owonongeka amatha kuwotchedwa pakanthawi kochepa ndipo kukana kwa malo osweka kumachepa.
●Ngati mukugwira ntchito limodzi ndi GD-4133 Cable Fault Tester, pali njira ziwiri zopezera:
a.Kuthamanga kwamagetsi otsika: Ngati mukugwiritsa ntchito GD-4133 kokha, chigawo chotseguka ndi zolakwika zochepetsera zowonongeka za chingwe zimatha kupezeka, ndipo kutalika kwa chingwe kumatha kuyesedwa, kapena kuthamanga kwa chingwe kumatha kudziwika.
b.High voltage flashover: Kutulutsa kwamphamvu kwamphamvu kwamagetsi kumayesedwa ndi kutulutsa malire, komwe kumatha kupeza mtunda wolakwika.
●Pangani chikoka cha ma frequency okhazikika.Ngati mukugwira ntchito limodzi ndi GD-4132 Cable Fault Locator, pali ntchito zotsatirazi:
a.Mafupipafupi a audio: pezani vuto lalikulu, zolakwika za flash-over.
b.Kuti muwone njira ya chingwe, zindikirani chingwe chapadera.
c.Kuwonongeka kwazitsulo (kufa pansi), pogwiritsa ntchito miyeso ya maginito kuti mupeze molondola.
●Itha kugwiritsidwanso ntchito mu DC HV kupirira mayeso.
●Kulowetsa mphamvu: AC 220V, 50Hz
●Mphamvu yamagetsi: DC 0-32kV (yosinthika)
●Adavotera mphamvu: 2kVA
●Max.mphamvu: 2048J, 4uF
●DC flashover voteji: 32kV
●DC Flashover panopa: 63mA
●Max.mphamvu yapano: 500mA
●Njira yotulutsira: DC HV, nthawi imodzi, kuzungulira
●Nthawi yotulutsa: 3-6 masekondi
●Kutentha kwachilengedwe: 0-40 ℃
●Chinyezi: <75% RH
●Kutalika: <1000m
●Mulingo wa insulation: A
●kukula: 430 * 540 * 410mm
●Kulemera kwake: pafupifupi 31kg.
GD-4132 Cable Fault Locator
Kuphatikizira gawo lalikulu, ma acoustic ndi maginito sensor, anti-noise headphone ndi charger.Ndikoyenera kuyesa mitundu yonse ya chingwe chamagetsi ndi kondakitala wazitsulo.Ntchito yake yayikulu ndikupeza malo osakwanira otchingira, kuzindikira kuzungulira ndi kuya kwa chingwe chamagetsi.
●Acoustic Magnetic kulandira nthawi yomweyo
●Mphamvu zotsutsana ndi kusokoneza
●Ndi mahedifoni oletsa phokoso.
●320 * 240 LCD chiwonetsero chazithunziBattery ya Li-yopangidwa ndi mphamvu yayikulu, yokhala ndi charger yothamanga.
●Acoustic ndi Magnetic sign waveform chiwonetsero, chizindikiro ndi phokoso ndizosavuta kusiyanitsa.
●Pogwiritsa ntchito cholozera kuyeza kuchedwa kwamayimbidwe ndi maginito, dziwani molondola pomwe pali vuto.Malinga ndi polarity koyambirira kwa maginito waveform, imatha kupeza ndikuzindikira njira.
1. Kupeza ntchito
a.Acoustic chizindikiro kufala gulu: pakati pafupipafupi 400Hz, bandiwifi 200Hz
b.Kuwonjezeka kwazizindikiro: 80dB
c.Malo olondola: 0.1m
2. Kupereka Mphamvu a.Omangidwa mu Li-batri, voteji mwadzina 7.4V, mphamvu 3000mAH.b.Kugwiritsa ntchito mphamvu: 300mA, nthawi yogwira ntchito mosalekeza 9hours.c.Chaja: inputAC220V±10%,50Hz.Kutulutsa mwadzina 8.4V, DC 1A d.Kulipira nthawi: 4hours
3. Kukula: 270mm * 150mm * 210mm
4. Kulemera kwake: 1.5kg.
5. Ntchito chikhalidwe Kutentha -10 ℃--40 ℃, chinyezi 5-90% RH, okwera <4500m
GD-4133 Cable Fault Detector
GD-4133 Cable Fault Detectot imagwiritsidwa ntchito kuyeza mtunda pakati pa zolakwika za chingwe.Ndi yosavuta ntchito ndi ndi wochezeka mawonekedwe.
Itha kugwiritsidwa ntchito yokha pansi pa low voltage pulse mode.Pansi pa kugunda kwapano, iyenera kugwira ntchito ndi jenereta ya GD-2131 high voltage.Pansi pa ma pulse mode angapo, GD-4133S coupler iyenera kugwiritsidwa ntchito limodzi.Mukapeza mtunda, cholozera cholakwika cha GD-4132 chiyenera kugwiritsidwa ntchito polozera zolakwika.Zogulitsazi zitha kuphatikizidwa kukhala zida zapamwamba kwambiri komanso makina oyesera ma chingwe.
●7inch LCD chophimba, wochezeka mawonekedwe.
●Njira zingapo zopezera mtunda:
Njira yotsika yamagetsi: ndiyoyenera kupeza cholakwika chochepa, cholakwika chachifupi, cholakwika chotseguka.Itha kugwiritsidwanso ntchito pakuyezera kutalika kwa chingwe, zolumikizira zapakatikati, zolumikizira za T, ndi kulumikizana kwa chingwe.Njirayi ingagwiritsidwenso ntchito kukonza liwiro la mafunde.
Njira yaposachedwa ya Pulse: Ndi yoyenera kuyeza mtunda wa vuto lalikulu la kukana, vuto losweka.Kugwiritsa ntchito coupler yapano kusonkhanitsa ma sign kuchokera ku waya wapadziko lapansi, kumapangitsa wosuta kukhala kutali ndi voteji yayikulu.Njirayi ndi yotetezeka komanso yodalirika.
Multiple pulse: njira yapamwamba yoyezera mtunda.Ma waveform ndi osavuta kuzindikira ndipo kulondola kwake ndikwambiri.
●200MHz zitsanzo zenizeni zenizeni.Max.0.4m kutalika kwa miyeso.Ili ndi zone yaing'ono yakufa ndipo ndi yapadera pa chingwe chachifupi komanso pafupi ndi chingwe cha fault.
●Kukhudza screen ndi kukanikiza makiyi ntchito
●Kope la PIP (chithunzi chosungira kwakanthawi)
●Padzakhala zenera lalikulu ndipo mazenera atatu osungira osakhalitsa amatha kuyang'ana ma waveform atatu palimodzi.
●Makina opangira opangira
Kuwongolera kwapadera kwa mapulogalamu okweza mapulogalamu, kusunga ndi kubwezeretsa.
●Sikelo ntchito
Poyambira, zolumikizira 10, vuto limodzi la chingwe ndi utali wonse zitha kukhazikitsidwa.
Onetsani masikelo ndi mawonekedwe oyeserera limodzi
●Kusungirako kwa Waveform ndi kulumikizana ndi kompyuta.
Kusungirako kwamkati kwa ma waveforms.
Ndi USB, kutsitsa kapena kukweza deta
Kulumikizana ndi kompyuta
●Kuwongolera mphamvu
Kuwala kwambuyo kumachepa ngati palibe ntchito mu 2mins ndikuzimitsa mu 10mins ngati palibe ntchito.
Batire yomangidwa mu Polymer Lithium-ion.
Nthawi yogwira ntchito ndi maola 5 pakugwiritsa ntchito kulikonse.
Mlandu wamphamvu, wosavuta kunyamula.
Njira zopezera | Njira yotsika mphamvu yamagetsi Impulse njira yokha Njira zingapo zokopa ngati zikugwirizana ndi GD-4133S |
Max.Zitsanzo pafupipafupi | 200MHz |
Kupeza osiyanasiyana | 0-70dB |
Low voltage impulse voltage | 30 v |
Max.kuthetsa | 0.4m |
Max.Malo osiyanasiyana | 100km |
Dead zone | 2m |
Batiri | Nickel-zitsulo hydride mabatire rechargeable, kupirira nthawi yoposa 5 hours |
Kulankhulana mawonekedwe | USB |
Magetsi | Lowetsani AC220V, 50Hz, 2A yamakono, kulipiritsa kwa maola 8 |
Dim. | 274 × 218 × 81mm |
Kulemera | 3.5kgs |
Kutentha kwa Ntchito | -10℃-40℃ |
Chinyezi | 5-90% RH |
Kukwera | <4500m |
GD-4133S Multiple Pulse Coupler
Ikugwira ntchito limodzi ndi GD-4133 Cable Fault Detector, yomwe imagwiritsidwa ntchito pozindikira vuto la kutayikira kwamphamvu, vuto la flashover, nthaka yocheperako komanso vuto lotseguka la zingwe zamagetsi.GD-4133S idapereka ma pulse coupling siginecha ya GD-4133 ndikuilekanitsa ndi zida zamagetsi apamwamba.
●Kugwiritsa ntchitoukadaulo wapamwamba kwambiri wa kuchuluka kwamphamvu ndi kugunda kwamtima. Mafunde owoneka bwino ndi osavuta kuzindikira.
●Ndi chitetezo cha HV chachitetezo, dera loyezera komanso mphamvu yamagetsi yayikulu imakhala yamagetsi.
●Mawaya osavuta, otetezeka komanso odalirika.
Zofotokozera
●Mphamvu yamagetsi: 300V (PP)
●Voltage yovomerezeka yolowera: <35kV
●Mphamvu zololeka zolowera: <2000J
●Kuyika kwamphamvu: 220VAC, 50Hz
●kukula: 560 * 230 * 220mm
●Kulemera kwake: 7kg.
Chizindikiritso cha Chingwe cha GD-2134D
Chizindikiritso cha Chingwe cha GD-2134D chimaphatikizapo chowulutsira ndi cholandirira, chitha kugwiritsidwa ntchito pofufuza ndi kuzama kwa zingwe zapansi panthaka ndi mapaipi achitsulo, komanso kuzindikira chingwe kuchokera pagulu la zingwe.
●Onetsani mwachindunji malo a chitoliro.
●Chizindikiro cha kumanzere/kumanja kwa Kutsata Njira Yachingwe.
●Yesani nthawi yeniyeni momwe chitoliro chikuyendera komanso nthawi yonyenga/yolondola pafupipafupi.
●Chizindikiro cholondola/chabodza.Idzaloza kutsogolo pamene chingwe chodziwika chikutsatiridwa bwino.Apo ayi, idzaloza kumbuyo ndipo idzawonetsa "?".
●Kuyeza mozama kwa kuya ndi kwapano.
●Chizindikiritso cha chingwe: Chizindikiritso cha clamp ndi chizindikiritso cha stethoscope.Chizindikiritso cha clamp chimatha kuyeza matalikidwe apano ndi momwe chingwe chikuyendera bwino ndikupereka zotsatira zolondola.Chizindikiritso cha Stethoscope ndi njira yachikale pomwe sikoyenera kugwiritsa ntchito chizindikiritso cha Clamp.Ndiwosavuta kuyimitsa chizindikiritso cha Stethoscope.
●Kugwiritsa ntchito choyikapo (chowonjezera) kuti mupeze vuto lomwe mukutchingira pansi.Sikoyenera kusinthira ku zero.Muviwu umasonyeza kumene pali vuto.
●Sampuli yolondola kwambiri ya digito ndi kukonza, yokhala ndi gulu lochepera lolandirira komanso kusokoneza kwakukulu.Imapondereza mphamvu pafupipafupi komanso kusokoneza kwa ma harmonic kuchokera ku zingwe zothamanga zapafupi.
●Kuzindikira mwachidwi komanso kuzindikira kwapang'onopang'ono.
●Batire ya Lithium yopangidwa ndi mphamvu yayikulu.Kuzimitsa kwamagetsi kukakhala kocheperako kapena osagwira ntchito kwa nthawi yayitali.
Wotumiza
●Kutulutsa (Mawonekedwe Atatu): Kutulutsa kwachindunji, Kutulutsa kwa Clamp Coupling (posankha), kulowetsedwa kwa radiation.
●pafupipafupi (6 posankha): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, kuphatikiza 640Hz ndi 1280Hz ndizovuta pafupipafupi.Ikhoza kuzindikira ntchito ya Zolondola/Zonama ndi chizindikiritso cha mapaipi mothandizidwa ndi Wolandira.
●Kutulutsa kwa siginecha yolakwika kuti muzindikire kulakwitsa kwa Pipe.
●Kutulutsa mphamvu: Max.10W, 10masitepe osinthika.
●Linanena bungwe mphamvu ya kugwirizana mwachindunji: Max.150Vpp.
●Zofananira zodziwikiratu zofananira ndi ntchito zachitetezo chochulukira & chitetezo chachifupi.
●Mphamvu yamagetsi: Batire ya Lithium yowonjezeredwa mkati, 4pcs, chitsanzo no.18650.mwadzina 7.4V, 6.8Ah.
●Zamphamvu komanso zonyamula.
Wolandira
●Njira yolowera: koyilo yolandirira yomangidwa, kulandira cholumikizira (chosankha), echometer(mwasankha), Choyika (chosankha).
●Magulu awiri ozindikira pafupipafupi: mphamvu pafupipafupi ndi mawayilesi (RF).Palibe chifukwa cholumikizira ndi jenereta yomvera pafupipafupi.
●Kulandila pafupipafupi:
Kuzindikira pafupipafupi: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
Kuzindikira pafupipafupi kwa PF: 50/60Hz ndi 250/300Hz (zosinthika)
Kuzindikira pafupipafupi kwa RF: pafupipafupi pakati ndi 10kHz, 33kHz, 83kHz motsatana.
●Njira yodziwira: njira yapamwamba, njira yopapatiza, njira yopanda pake.
●320 * 240 mapikiselo LCD chophimba.
●Batire ya lithiamu yomangidwanso, 2pcs 18650 Li batire, nominal.7.4V, 3.4Ah.
●Zamphamvu komanso zonyamula.
Mafotokozedwe ena
●Kukula: thiransifoma 270 * 220 * 85mm, wolandila 700 * 270 * 120mm.
●Kulemera kwake: transmitter 2.2kg, wolandila 2.2kg.
●Chaja: athandizira AC 100-240V, 50/60Hz, linanena bungwe DC 8.4V, 2A.
●Ntchito chikhalidwe: Kutentha -10--40 ℃.Chinyezi 5-90% RH, Altitude<4500m.
GD-2135 Cable Puncture Chipangizo
GD-2135B Cable Puncture Chipangizo ndinso chozindikiritsa chingwe, kuzindikira chingwe kuchokera pagulu la zingwe.
Ndi chipangizo chopumira chopanda kulumikizidwa, chokhala ndi zowongolera zakutali komanso nthawi.
Chipangizochi chili ndi magawo awiri, chipangizo chokhomerera komanso chowongolera.Imayendetsedwa ndi batri, yomwe imalekanitsa chipangizo cha puncture kuchokera kumagetsi, kuonetsetsa chitetezo chamagetsi.
●Ndi oyenera kubowola mitundu yonse ya mphamvu chingwe, otetezeka ndi odalirika.
●Njira ziwiri zogwirira ntchito, kuphatikiza kutali ndi nthawi.Mabatani awiri oti agwiritse ntchito kulowa munjira yogwirira ntchito, onetsetsani chitetezo cha wogwiritsa ntchito.
●Mabatani awiri akutali (kiyi C ndi D adakanikiza nthawi imodzi).Kuti muwonetsetse kulandila kodalirika, mlongoti wotumizira wa remote control uyenera kutulutsidwa kwathunthu.
●Kugwiritsa ntchito mfuti ziwiri kuti kuboola ndi ngodya ziwiri.Mmodzi kuyesa ntchito kumaliza pawiri punctures.
●Ndi alamu yomveka komanso chiwonetsero cha LCD.
●Mapangidwe angapo otetezedwa ndi makina ndi zamagetsi.
●Zapadera zopangidwira zoboola chingwe, zokhazikika mwachindunji pa chingwe, zomwe zimayikidwa pa ngodya iliyonse.
●Kugwiritsa ntchito mphamvu ya batri, yoyenera kugwiritsidwa ntchito mopanda mphamvu.Komanso, amapatula chipangizo puncturing dongosolo mphamvu, kuonetsetsa chitetezo.
●Mtunda wakutali wopanda zingwe: ≤ 20M.
●Kugwiritsa ntchito chingwe: zingwe zonse zamagetsi ≤ ¢125mm
●Mphamvu yogwira ntchito: 6pcs 1.5V batire.
●Ntchito chikhalidwe: kutentha -10-50 ℃, chinyeziRH <95%.
●Kulemera: 15kg kuphatikizapo aluminium kesi.
●kukula: 48 * 45 * 16cm