GDYZ-302W Metal Oxide Arrester (MOA) Tester
1) Kutayikira panopa, AC panopa
Mtundu | Kusamvana | Kulondola |
0.000mA~1mA | 1uA ku | ±1% rdg±8dgt |
1.00mA~10.00mA | 0.01mA | |
10.0mA~100.0mA | 0.1mA | |
100mA~300mA | 1mA |
2) High-order harmonic panopa (mafunde ofunikira panopa, wachitatu harmonic panopa)
Kuyika kwa mafunde ochepa kwambiri | Pamwamba pa 3% yamtundu uliwonse |
Kulondola | 1%rdg±8dgt (± AC zolondola pakali pano) |
Ntchito | Poyesa mphamvu zonse za zinc oxide arrester, zitha kuweruzidwa pa intaneti ngati chomangira cha zinc oxide chawonongeka, komanso chitha kugwiritsidwa ntchito ngati ultra-precision clamp-on leakge mita yapano. |
Magetsi | Host: DC 7.4V 2000mAh rechargeable lithiamu batire, batire ili pafupi 8.4V yodzaza kwathunthuChodziwira: DC 7.4V 2600mAh batire ya lithiamu yowonjezeredwa, batire ili pafupifupi 8.4V yodzaza kwathunthu |
Njira yoyesera | Kuwongolera kwa CT |
Muyezo osiyanasiyana | AC 0.000mA~300mA (mtengo wothandiza) |
Max.kuthetsa | 1μA |
Kulondola kwa miyeso | ±1% rdg±8dgt (23℃±5℃, pansi pa 80% RH) |
Kulankhulana opanda zingwe | 433MHz kulumikizana opanda zingwe |
mtunda wotumizira opanda zingwe | 30m ku |
Onetsani mawonekedwe | 3.5-inch mtundu chophimba;chiwonetsero chazithunzi: 71mm×53 mm pa |
Kukula kwa chida | Kutalika: 195 mm×100 mm×45 mm;Chowunikira: 208mm×131 mm×90 mm |
Kulemera kwa chida | Host: pafupifupi 400g;detector: pafupifupi 1220g,Zonse: pafupifupi 7000g (kuphatikiza ndodo zotchingira ndi zowonjezera) |
Kukula kwa clamp | φ40 mm |
Chiwerengero cha zitsanzo | 2 nthawi/s |
Kusungirako deti | Magulu 200, chizindikiro cha "HOLD" chikuwonetsa panthawi yosungira. |
Data hold | Mumayendedwe oyesera, dinani batani la HOLD kuti musunge deta ndikusunga deta, chizindikiro cha "HOLD" chikuwonetsedwa, ndiyeno dinani batani la HOLD kuti musiye. |
Kuyang'ana deta | Chizindikiro cha "WERENGANI" chikuwonetsa kuti zomwe zasungidwa zitha kutembenuzidwa mmwamba ndi pansi. |
Kusefukira | “OL” zikuwonetsa kuchuluka kwa mayeso. |
Palibe chizindikiro | Pamene wolandira alendo sakulandira chizindikiro cha detector, malo omwe alipo panopa sangathe kuwonetsedwa. |
Auto kuzimitsa | Chidacho chidzazimitsa chokha pambuyo pa 10min kuti mupulumutse batri. |
Mphamvu ya batri | Pamene mphamvu ya batri ili pansi pa 7.8V, imasonyeza kuti ndi nthawi yoti musinthe batire. |
Mphamvu yamagetsi | 35kV ndi pansi |
Kutentha kwa chilengedwe ndi chinyezi | -20℃~40℃; pansipa80% Rh |
Kusungirako | -20℃~60℃;pansipa70% Rh |
Kusokoneza | No 433MHz kusokoneza kwa ma frequency |
Insulating ndodo kukula | 4-gawo kankhani-batani telescopic insulating ndodo (yotalikirapo 5m, otsekedwa boma 1.5m, m'mimba mwake φ44mm) |
Mphamvu ya insulation | Single insulating ndodo AC110kV/rms, chipolopolo cha HVchodziwirapakati pa chitsulo pakati: AC1000V/rms |