GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Insulation Resistance Tester imagwiritsidwa ntchito kwambiri pokonza zida zamagetsi m'malo osinthira thiransifoma, malo opangira magetsi, ndi zina zambiri. Ndizoyenera kuchita kuyeza kukana kwa insulation (IR), chiŵerengero cha mayamwidwe (DAR), polarization index (PI), Leakage current (Ix) ndi mayamwidwe capacitance (Cx) mitundu yonse ya zida voteji mkulu, kuphatikizapo switchgear, thiransifoma, reactors, capacitor, motors, jenereta ndi zingwe, etc.
●Imatengera kuwongolera kwamakompyuta ang'onoang'ono, magwiridwe antchito a menyu ndi chiwonetsero chachikulu cha madontho a LCD okhala ndi magwiridwe antchito okhazikika.
●Kutha kwamphamvu kotsutsana ndi kusokoneza, koyenera kuyeza m'malo amphamvu osokoneza ma elekitiroma.
●Kuchuluka kwakukulu, kumatha kukwaniritsa zofunikira zamagetsi apamwamba, kukana kwakukulu, kuyesa kwakukulu kwa katundu.
●Ndi mawonekedwe a shockproof, chinyezi komanso fumbi, sinthani ndi malo ogwirira ntchito ovuta.
●Zosavuta kugwiritsa ntchito, wonetsani zotsatira zolondola komanso kusintha kwa data.
●Chitetezo chokwanira, chotha kupirira kukhudzidwa kwafupipafupi komanso mphamvu yotsalira yotsalira yamagetsi.
●5 voteji linanena bungwe masitepe 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 voteji linanena bungwe masitepe 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Mphamvu yamagetsi ya sitepe iliyonse imasinthidwa mosalekeza kuchokera ku zero.
●Linanena bungwe mkulu voteji angathenso mosalekeza kusinthidwa.
●Muyezo wodziwikiratu wa R15, R60, R600, kuwerengera kwachiwerengero cha mayamwidwe, index polarization.
●Muyezo waukulu wa kukana ndi 0~10TΩ (0~20TΩ), masinthidwe osiyanasiyana.
●Kuyeza modzidzimutsa kwa kutentha kozungulira, chinyezi cha mpweya ndi nthawi yoyesera.
●Imawonetsa nthawi yoyesera, maupangiri a buzz pamasekondi 15 aliwonse, mphindi 5 popanda opareshoni zimathandizira kutseka.
●Kutulutsa voteji yayikulu mukatha kuyeza, nthawi yotulutsa sipitilira masekondi 30.
●Kusungirako kwa magulu 60 a zotsatira zoyezera, zosasinthika kwa zaka 20.
●Ndi mawonekedwe amtundu wa RS232, amatha kulumikizana ndi kompyuta.
●Ndi chosindikizira kunja, akhoza kusindikiza muyeso zotsatira.(posankha)
●Mphamvu yachitsanzo cholipiridwa imawonetsedwa musanayesedwe ndipo ili ndi malangizo ofunikira.
●Khazikitsani nthawi yoyeserera, kuyimitsa muyeso;
●Kutha kuzindikira kutayikira kwa Ix pano komanso mayamwidwe a Cx.
Adavotera masitepe a voltage test | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Kulakwitsa kwamagetsi otulutsa | ± 5% | ||||||
Kukana osiyanasiyana | Malire apamwamba | 500GΩ~10TΩ pa | |||||
Kuchepetsa malire | 0.1MΩ | ||||||
Kalasi yolondola | 5.0 kalasi | ||||||
Vuto lalikulu lamagetsi | ±( 5%•Ux + 1digital) | ||||||
Zoyezera zaposachedwa za Ix ndi zolakwika | 0.1nA~9.9mA 5% | ||||||
Absorption capacitance Cx kuyeza ndi zolakwika | 0.1pF~99ɥF 5% | ||||||
Cholakwika pakuyezera kutentha | ± 0.5 ℃ | ||||||
Cholakwika pakuyezera chinyezi | ± 2% RH | ||||||
Short circuit panopa | <6mA | ||||||
Mphamvu yamagetsi | <3% | ||||||
Nthawi yoyesera | Mpaka mphindi 99 | ||||||
Insulation resistance | > 500 MΩ (pakati pa mawaya oyesera ndi mlandu) | ||||||
Kupirira voltage | AC10.0kV 50Hz 1min (pakati pa mawaya oyesera ndi mlandu) | ||||||
Magetsi | 12V lithiamu batire | ||||||
Nthawi yantchito ya batri ikatha kuyitanitsa kamodzi | 30days 10times DAR & 5times PI mayeso patsiku | ||||||
Ntchito kutentha ndi chinyezi | 0 ℃ ~ + 40 ℃ <85%RH | ||||||
Kusungirako kutentha ndi chinyezi | -20℃ ~ + 50℃ <90%RH | ||||||
Magetsi | 220V AC 50Hz | ||||||
kukula (mm) | 325 (L)*250(W)*130(H) | ||||||
Kulemera | 3.7kg | ||||||
Vuto loyesa kukana | |||||||
Masitepe a Voltage | 250 V | 500 V | 1.0 kV | 2.5 kV | 5.0 kv | 10 kV | |
±( 3%·Rx + 1d) | 1gΩ pa | 2GΩ pa | 4gΩ pa | 10GΩ pa | 20GΩ | 40GΩ pa | |
±( 5%·Rx + 1d) | 10GΩ pa | 20GΩ | 40GΩ pa | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
±( 10%·Rx + 2d ) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ pa | 2 T | 4TΩ pa | |
±( 25%·Rx + 2d) | 500GΩ | 1TΩ pa | 2TΩ pa | 5TΩ pa | 10TΩ pa | 20TΩ pa |
Insulation resistance tester | 1 seti |
Yesani chingwe cholumikizira cha L terminal (Yofiira) | 1 muzu (chidutswa chimodzi) |
Yesani chingwe cholumikizira cha G terminal (Yobiriwira) | 1 muzu (chidutswa chimodzi) |
Yesani chingwe cholumikizira cha E terminal (Chakuda) | 1 muzu (chidutswa chimodzi) |
3APower adaputala (Pamagetsi osindikizira ndi kulipiritsa zida) | 1 piece (chidutswa chimodzi) |
RS232 serial kulumikizana mzere | 1 muzu (chidutswa chimodzi) |
Wogwiritsa's chitsogozo | 1 kope (chidutswa chimodzi) |
Lipoti la mayeso | 1 kope (chidutswa chimodzi) |
1. L zitsulo zotayira 2. G zotsekemera 3. E terminal socket 4. LCD screen
5. Buzzer 6. Temperature & humidity sensor 7. ESC batani 8. UP batani
9. Kusiyanitsa mfundo 10. PASI batani 11. OK batani12. Mkulu voteji kusintha knob
13. Mawonekedwe a RS232 14. Kusintha kwa mphamvu15. Soketi yopangira