GDBR-P Transformer Load No-load and Capacity Tester
●Yesani thiransifoma No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
●Njira zoyesera mamita atatu.
●Pamene kupanga atatu gawo thiransifoma No-katundu, katundu mayeso, chida adzaweruza ngati mawaya zolondola basi, ndi kusonyeza atatu gawo voteji, panopa vekitala chithunzi.
●Malizitsani mayeso olemetsa pansi pa 1600kVA pansipa yogawa thiransifoma yodzaza ndi makina amodzi.Malizitsani 2500kVA pansipa kuyesa kwa thiransifoma yogawa pansi pa 1/3 yovotera pano (Pansi pa 1/3 yomwe idavotera pano, chidachi chitha kusinthidwa kuti chikhale chotayika potengera masiku ano.)
●Zotsatira zonse zoyeserera zimakonzedwa zokha.Chida chowongolera chodziwikiratu motere, kukonza mawonekedwe a waveform, kuwongolera kutentha, Kuwongolera kwamagetsi sikunavotere komanso kuwongolera komwe sikunavotere.Zotsatira za mayeso ndizolondola.
●320 * 240 yowala kwambiri LCD chophimba, ndi kusintha kuwala.Mabatani okhudza amapangitsa kuti ntchitoyi ikhale yosavuta.
●Wotchi yanthawi yeniyeni, tsiku lojambulira loyesa zokha, loyenera kusungirako ndikuwongolera zotsatira za mayeso.
●Chosindikizira chotenthetsera chomangidwira mkati, zotsatira za mayeso osindikiza mwachangu.
●Yambitsani pansi sitolo ndikusakatula deta (chinthu choyesera, zotsatira zoyezera, nthawi yoyesera) ntchito.Sungani mpaka 500groups mayeso zotsatira, deta kufala Intaneti PC.
●Amalola muyeso wotalikirapo wa thiransifoma yakunja ndi thiransifoma yamakono.Yezerani chinthu choyesera cha magawo aliwonse.
1. Zinthu zoyesa
●RMS ya voteji magawo atatu: Uab, Ubc, Uca.
●Avereji yamagetsi a magawo atatu a AC: Uab, Ubc, Uca.
●RMS ya magawo atatu apano: Ia, Ib, Ic.
●Maperesenti a Kutayika Kwapang'onopang'ono ndi Kupanda katundu wapano: Po, Io%.
●Kutayika kwa katundu, kuchuluka kwa mphamvu yamagetsi, kusokoneza kwafupipafupi: Pt, ekt, Zt.
●Kutayika kwa katundu, peresenti yamagetsi ya impedance ndi impedance yafupipafupi pa kutentha kulikonse.
●Transformer mphamvu yeniyeni ndi mphamvu zoweruzidwa.
2. Main luso magawo
●Muyezo wapano: 100mA-60A, kulondola:kalasi 0.2.
●Kuyeza kwamagetsi: 10V-650V, kulondola: kalasi 0.2.
●Transformer yakunja imatha kukulitsa kuchuluka kwa kuyeza kwa chida.
●Muyezo wa pafupipafupi: 40-65Hz, kulondola: kalasi 0.2.
●Kuyika kwamphamvu: AC220V± 10%.
Main Unit | 1 pc |
Chingwe champhamvu | 1 pc |
Chingwe choyezera clamp | 1 seti |
Chingwe chapadera chachifupi | 1 pc |
Wogwiritsa ntchito | 1 pc |
Lipoti la mayeso a fakitale | 1 pc |