GDFJ-VI Transformer Yosungunuka Gasi Analyzer
GDFJ-VI Transformer Dissolved Gas Analyzer ndi chromatograph ya gasi yonyamulika yoyenera kusanthula mwachangu pamalopo.Imaphatikiza kuzindikira kwa chromatographic, kusanthula ndi kuzindikira m'modzi, komanso chowunikira chaching'ono, mini gasi gwero ndi kompyuta yolumikizidwa yolumikizidwa.Ili ndi kuphatikiza kwapamwamba, kukhazikika bwino, mawonekedwe osalimba komanso magwiridwe antchito osavuta kuposa chromatography yamafuta onyamula.Kusanthula patsamba kumatha kusanthula munthawi yake ndikuzindikira zolakwika za thiransifoma, kupangitsa mphamvu kuti ikhale yosavuta komanso yosavuta.Chidacho chimatengera njira yachikale ya zowunikira zitatu, ndipo zowunikira ndizofanana ndi zamachromatograph a labotale.Chidacho chimatengera lingaliro laling'ono laling'ono lopangidwira.Ili ndi kuphatikiza kwakukulu, kukula kochepa ndi kulemera kopepuka, komwe kumakhala kosavuta kunyamula kumalo kuti afufuzidwe.Imapereka chidziwitso chapanthawi yake komanso cholondola pakuwunika ndi kuyesa kwa thiransifoma, ndikupulumutsa anthu ambiri ndi zinthu zakuthupi.
Kusanthula kwathunthu kwa zomwe zili mu magawo asanu ndi awiri a gasi H2, CO, CO2, CH4, C2H4, C2H6, C2H2(hydrogen, carbon monoxide, carbon dioxide, methane, ethylene, ethane, acetylene) osungunuka mu mafuta otetezera amatha kutha mu jekeseni imodzi.Kuchulukitsidwa kocheperako kwa acetylene ndi 0.1ppm, ndipo kwagwiritsidwa ntchito bwino m'mafakitale ambiri ndi madipatimenti monga makampani opanga magetsi, mafakitale opanga magetsi, mafakitale osinthira, mabizinesi akuluakulu osungunula, ndi magawo opangira magetsi a njanji.
●Tekinoloje yomangidwa mu touch screen anti-control kuti muzindikire kuwonetsa kwamphamvu kwa mpweya wa zida.
Kuthamanga konse kwa mpweya kumawonetsedwa ndi digito ndi sensor sensor.Kupanikizika kwa mpweya wonyamulira, gasi wa haidrojeni ndi mpweya zitha kuwerengedwa mwachindunji kudzera m'malo ogwirira ntchito, ndipo mikhalidwe yowunikira imatha kuzindikirika munthawi yeniyeni.
●Kugwiritsa ntchito ukadaulo woletsa kuwongolera pazenera kuti mukwaniritse kutentha kwa zida, kuwonetsa ndi ntchito zina.
Magawo onse otentha amatha kuwonetsedwa pa digito.Kutentha kwa bokosi lazanja, detector ndi reformer kumatha kuwerengedwa ndikuwongoleredwa mwachindunji ndi malo ogwirira ntchito.Ntchitoyi ndi yosavuta komanso yomveka bwino.
●Dinani pazenera lokhudza kuti mumalize kutentha, kuziziritsa, kuyatsa ndi zosintha zapano.
Anamanga-mu basi mpweya njira kulamulira chipangizo basi amachotsa mbali ya mpweya pamene ntchito pa kukhudza chophimba, kuti chiŵerengero cha haidrojeni mpweya kufika chiŵerengero oyenera poyatsira, ndi kubwezeretsa chiŵerengero pambuyo poyatsira anamaliza basi;Momwemonso, kudzera pawindo lokhazikitsira mlatho mu pulogalamu yogwirira ntchito mutha kumaliza kuyika kwakuyenda kwa mlatho wotentha.
●Tekinoloje ya Digital FID yamagetsi ya zero-setting kuti ipititse patsogolo luso loletsa kusokoneza chidacho.
FID detector imagwiritsa ntchito ukadaulo wa zero-setting wamagetsi ndi mayendedwe olondola kwambiri a digito kuti alipirire zoyambira pakalipano za FID, kuti azindikire kuwongolera kwamagetsi pamlingo wotuluka wa FID.Chifukwa lamulo lamagetsi likhoza kukhazikitsidwa mwachindunji pa njira yamagetsi ya boardboard kuti apititse patsogolo mphamvu zamagetsi zamagetsi, palibe chizindikiro chosokoneza pamene potentiometer imagwirizanitsa.Chifukwa chochepetsa magawo a parasitic, ali ndi mphamvu zotsutsana ndi kusokoneza.
●Kugwiritsa ntchito makompyuta odana ndi kulamulira luso kukwaniritsa ulamuliro wa oscillator.
Kupyolera mu chingwe cholumikizira chizindikiro, chikhoza kupereka mphamvu kwa oscillator yaing'ono, ndipo kupyolera mu malo ogwirira ntchito, amatha kugwiritsa ntchito njira yonse ya oscillator, monga kutenthetsa, kuyambira oscillation, kuyimirira, kuphulika mwamsanga kumapeto, etc.ystem mu Chingerezi ndi Chitchaina, zomwe zitha kusinthidwa momasuka.
●Pampu yampweya yomangidwa mkati, yopanda mpweya wakunja.
Ndi pompu yaing'ono yochokera kunja mkati mwa injini yaikulu, imatha kupereka mpweya wa chipangizocho mosasokonezeka.Chifukwa cha kapangidwe kake kopanda mantha, pampu ya mpweya imatha kugwira ntchito mwakachetechete, ndipo wogwiritsa sangamve ngati ilipo.
●Ntchito yoteteza kuphulika kwa gasi ya waya wotentha wa tungsten.
Ndi wanzeru matenthedwe cutoff chitetezo ntchito, pamene chonyamulira mpweya kukakamiza ndi zochepa polowera chitetezo, dongosolo basi kudula madutsidwe matenthedwe panopa kuteteza matenthedwe conductivity chowunikira kuti chiwonongeke.
Chigawo | Min.kuzindikira ndende |
H2 | 2 |
CO | 5 |
CO2 | 10 |
CH4 | 0.1 |
C2H4 | 0.1 |
C2H6 | 0.1 |
C2H2 | 0.1 |
FID (chowunikira chamoto cha ionization)
●Malire ozindikira: Mt≤3×10-12g/s (Hexadecane/isooctane)
●Phokoso loyambira: ≤5 × 10-14A
●Kusintha koyambira: ≤1 × 10-13A / 30min
●Mzere wa mzere: ≥ 106
TCD (thermal conductivity detector)
●Sensitivity: S≥3500mV•ml/mg (zachizolowezi);5000mV•ml/mg (zovuta kwambiri)
●Phokoso loyambira: ≤10μV
●Kusintha koyambira: ≤30μV/30min
●Mzere wa mzere: ≥104
Temperature control index
Gawo lowongolera kutentha | Mtundu | Kulondola |
Column box | 4 ~ 450 ℃pamwamba pa kutentha kwa chipinda | ± 0.1℃ |
Wodzaza column injector | 4 ~ 450 ℃pamwamba pa kutentha kwa chipinda | ± 0.1℃ |
FID Detector | 4 ~ 450 ℃pamwamba pa kutentha kwa chipinda | ± 0.1℃ |
TCDChodziwira | 4 ~ 450 ℃pamwamba pa kutentha kwa chipinda | ± 0.1℃ |
Kusintha kwa nickel catalyster | 4 ~ 450 ℃pamwamba pa kutentha kwa chipinda | ± 0.1℃ |
Ena
kukula: 420 * 280 * 300mm
Kulemera kwake: ˂15kg
Mphamvu: AC220V ± 10%, 50Hz
Ayi. | Dzina | Kufotokozera | Qty. |
1 | Mtengo DGA | GDFJ-VI | 1set |
2 | Chromatography ntchito | Makina oteteza mafuta apadera | 1set |
3 | Miniature Full Automatic Oscillator | 1set | |
4 | Nayitrogeni Yapamwamba Kwambiri | 2L, 99.999%, Aluminiyamu aloyi botolo | 2mabotolo |
5 | High Purity Hydrogen | 2L, 99.999%, Aluminiyamu aloyi botolo | 1botolo |
6 | Standard Gasi | 2L, 7 zigawo, Aluminiyamu aloyi botolo | 1botolo |