GDW-102 Mafuta Dew Point Tester (Coulometric Karl Fischer Titrator)
Ukadaulo wa Coulometric Karl Fischer umagwiritsidwa ntchito kuyeza ndendende chinyezi chomwe chimayezedwa chomwe chilipo. Ukadaulo umagwiritsidwa ntchito kwambiri pakulondola komanso mtengo wotsika mtengo woyeserera. The Model GDW-102 muyeso amafufuza ndendende chinyezi pamadzi, olimba ndi gasi zitsanzo malinga ndi luso.Amagwiritsidwa ntchito mu magetsi, mafuta, mankhwala, zakudya ndi zina zotero.
●Gwiritsani ntchito gawo lowongolera la PWM la electrolysis kuti muchepetse kutaya mphamvu kwa chidacho.
●Kuyeza kolondola kwambiri kwa ma elekitirodi ndi kuzindikira kwa dera kumapangitsa chisankho chomaliza cha electrolytic mwachangu komanso moyenera ndi mphamvu zotsutsana ndi kusokoneza.
●Gwiritsani ntchito njira zolipirira ma electrolyte opanda kanthu komanso chipukuta misozi cha electrolyte kuti mupange zotsatira zoyesa.
●Zopangidwa munjira zitatu zowerengera kuti mupange lipoti lokha.
●Mabatani omwe amawongolera liwiro losakanikirana amakhala ndi liwiro khumi (0 ~ 9speed).
●Yezerani vuto lotseguka la ma elekitirodi ndi vuto lalifupi lachifupi lokha.
●Itha kusunga mbiri yakale 256 ndi nthawi.
●Wotchi ya kalendala yokhala ndi kutentha imatha kusunga tsiku ndi nthawi yoyezetsa molondola, yomwe imatha kugwira ntchito zaka 10 m'mwamba ndikutsika mphamvu.
●Chidacho chikapanda kugwira ntchito kwa nthawi yayitali, chophimba cha LCD chimazimitsa chokha kuti chiteteze chinsalucho ndikukhalitsa chinsalucho.Dinani mabatani aliwonse kuti musiye chitetezo chowonekera.
●Pali mawonekedwe a RS232 olumikizirana ndi PC ndi mini-printer mosavuta.
Electrolysis panopa | Max.400mA |
Max electrolysisliwiro | Max.2.4mg/mphindi |
Muyezo osiyanasiyana | 10 ug~100 mg |
Kumverera | 0.1ug |
Kulondola | ±3ug kwa 10ug~1 mg pa RSD 0.3% kapena kuchepera kwa 1mg kapena kuposa |
Ambient Kutentha | 5~35℃ |
Chinyezi chozungulira | ≤85% RH |
Magetsi | AC220V±20% 50HZ±10%,40VA |
Makulidwe | 270×210×125(mm) |
Kulemera | 5kg |
Kugwiritsa ntchito mphamvu kwambiri | 30W ku |
Chigawo chachikulu | 1 chidutswa |
Electrolysis electrode | 1 chidutswa |
Electrode yoyezera | 1 chidutswa |
Kusakaniza mtedza | 2 ma PC |
silika gel osakaniza | 1 chidutswa |
silika gel osakaniza | 10 ma PC |
0.5μl Chitsanzo chojambulira | 1 chidutswa |
50μl jekeseni wa chitsanzo | 1 chidutswa |
1 ml ya jekeseni wa chitsanzo | 1 chidutswa |
Kuyanika chubu | 1 chidutswa |
Chingwe champhamvu | 1 chidutswa |
Vacuum mafuta | 1 chidutswa |
Electrolyte | 1 chidutswa |
Wogwiritsa ntchito | 1 kopi |
Lipoti la mayeso a fakitale | 1 kopi |