GDWG-V SF6 Gas Leak Detector (mtundu wa IR, Kuwonetsa kawiri)
GDWG-V SF6 Gas Leak Detector ndi infrared red leak detector (NDIR teknoloji) yokhala ndi mawonedwe awiri.Ndi mtundu wa INCELL TFT wowonetsa komanso nthawi yeniyeni ikuwonetsa kukhazikika kwa SF6.Imazindikira mwachangu SF6 breaker, GIS leakage point komanso kutayikira kwapachaka moyenerera komanso mochulukira.Ndi chipangizo chabwino choyenera dipatimenti yamagetsi, unsembe ndi kukonzanso unit, mphamvu mayeso Institute.
●Zida Zosinthira Mphamvu Yamagetsi Apamwamba
●Rotor Vane ya helikopita
●Njira yotumizira gasi
●Kuzindikira chozimitsira moto
●Kafufuzidwe ka mpweya wabwino wa Zomangamanga
●Kuzindikira zoopsa
●Palibe ma radiation.
●Palibe chifukwa chosinthira mpweya wabwino kwambiri wa argon nthawi zonse.
●Palibe chifukwa choyandikira mpweya wothamanga kwambiri.
●Palibe chifukwa chosinthira masensa pafupipafupi, okwera mtengo.
●Kuchita kokhazikika, mtengo wotsika wokonza.Palibe chifukwa chopanga ma calibration a mzere chaka chilichonse.
●Palibe kukhudzidwa ndi chinyezi ndi kuipitsidwa kwa chilengedwe.
●Kukhudzika kwakukulu, mpaka 0.01ppmv.
●Pamene kutayikira kwakukulu kapena kusungunuka kwa mpweya wa SF6 kufika pa 100%, sikudzaipitsidwa kapena kuonongeka.
●Chojambula cha TFT In-Cell, chowonetsera kawiri, chowoneka ndi kuwala kwa dzuwa.
●Batire ya Lithium yomangidwa.
●Alamu yotchulidwa ndi ogwiritsa ntchito yokhala ndi phokoso ndi kuwala.
●High tilinazo ndi kukhazikika bwino.
●Kuthamanga koyezera mwachangu, nthawi imafika 3s.
●Kutentha ndi kupsinjika maganizo.
●Kuyankha kokha kwa gasi wa SF6, osati gasi wina.
●Zinthu zoyezera zosagwirizana ndi gasi zimatsimikizira kuti palibe poizoni wa sensa yomwe idzachitika pamtundu uliwonse.
●Chipinda chotenthetsera cha sensor nthawi zonse chimatha kuwonetsetsa kuti sensa ilibe kutentha kwa kutentha kulikonse.
●Kukula kochepa, kosavuta kunyamula, koyenera kugwira ntchito pamalopo.
●Ndi zingwe za gasbag zosatsetsereka, zomasuka kunyamula.
●Kusunga deta mpaka 100groups.
●Aluminiyamu yowala kwambiri yokhala ndi chipolopolo chotchinga chonse.
●Phukusi lakunja limagwiritsa ntchito pulasitiki yauinjiniya, yopanda madzi, yopanda fumbi.
●Mfundo yoyezera: Sensa ya infrared yopanda dispersive (NDIR)
●Muyezo osiyanasiyana: 0-2000ppmv SF6 kapena 0-50ppmv
●Kusamvana: 0.1ppmv kapena 0.01ppmv
●Kulondola: ±2%FS(0-1000ppm)
●Vuto lobwerezabwereza: ≤± 1%
●Kumverera: 0.1ppmv
●Nthawi yoyankha: ≤2s
●Nthawi yobwezeretsa: ≤5s
●Kukhazikika: ≤± 20ppm, kuposa 1000hours
●Kusintha kwa ziro: ≤± 1% (FS/chaka)
●Kulakwitsa kwa mzere: ≤± 1%
●Kutentha kosungira: -20°+60 ℃
●Kutentha kwa ntchito: -20°+50℃
●Sampling mode: Pampu yopangidwa ndi electromagnetic diaphragm, mtundu wokhazikika wokhazikika, umayenda mpaka 1L/min.
●Voltage yogwira ntchito: 220VAC ± 10%, 50Hz Kapena Li-battery yomangidwa, 8hours ikugwira ntchito.
●Kukula: 160 × 220 × 70mm, mfuti yamanja 106mm * 170mm * 120mm.
●Kulemera kwake: gawo lalikulu la 1.5kg, mfuti yamanja pafupifupi 0.5kg