GD8000C SF6 Gas Leak Online Monitoring System
GD8000C quantitatively leak online monitoring system imagwiritsidwa ntchito makamaka mu chipinda chosinthira cha 35KV SF6 ndi chipinda cha 500KV, 220KV, 110KV GIS m'chipinda chocheperako kuti chiwunikire kutayikira kwa mpweya wa SF6 mu chipinda cha SF6 chophatikiza zida zamagetsi ndi mpweya womwe uli mumlengalenga munthawi yeniyeni. .
Pamene mpweya wa SF6 ukutuluka, kachulukidwe ka gasi wa SF6 ndi woposa 5 nthawi ya mpweya, yomwe imawunjikana m'malo otsika ndikupangitsa kusowa kwa okosijeni m'deralo, zomwe zingayambitse ngozi zazikulu.Dongosololi limagwiritsa ntchito ma seti angapo a masensa atsopano a SF6-O2 omwe amachokera kunja komanso kutentha ndi chinyezi.Pamene m'nyumba SF6 ndi O2 ndende kusintha pang'ono, masensa akhoza kuyankha kusintha kumeneku nthawi yomweyo, ngakhale SF6 ndende ndi 10ppmv akhoza bwinobwino kuyang'aniridwa.
Kusintha koyang'aniridwa ndi sensa kumasinthidwa kukhala chizindikiro cha digito cholumikizira 485 ndi transmitter, gawo la A / D, gawo lolumikizana la 485 ndi microcomputer single-chip, ndipo chizindikirocho chimatumizidwa kwa wolamulira wamkulu kudzera pa tsamba la RS-485. basi.Woyang'anira wamkulu amachita ndondomeko ya deta ndi kusunga, ndikuweruza ngati akuwombera, yambani fani ndi kulankhulana kwakutali ndi ntchito zina.
●Indoor GIS kuwunika zachilengedwe
●Kuyang'anira chilengedwe cha chipinda chamkati cha SF6 switchgear
●SF6 kupanga gasi wapamwamba kwambiri
●R & D cholinga
●10.1inch touch color color screen.
●Kusankhidwa kwa sensa kumasinthasintha, ndipo masensa a infrared, ma electrochemical sensors, ndi masensa akupanga ndizosankha.Malingana ndi malo osiyanasiyana, imatha kusinthidwa mwachisawawa komanso yosinthika.
●Bokosi la ma ARM la Industrial-class, lomwe limathandizira pulogalamu yabwino kwambiri ya OS, imapangitsa kuti malondawo akhale odalirika.
●Algorithm yoweruza yanzeru imatha kuchotsa chenjezo labodza la sensor chifukwa chazifukwa zosiyanasiyana.
●Kuwongolera kwanzeru zero Drift kumakulitsa moyo wa sensor.
●Ntchito yowunikira thupi la munthu.Munthu akafika pakhomo la malo omwe amayang'aniridwa, gawo lalikulu limadziwiratu chizindikiro cha thupi la munthu.Gawo lalikulu lidzayamba nthawi yomweyo ndikupereka lipoti lowunika za chilengedwe.
●Deta ya alamu ndi pulogalamu ya mpweya wabwino imakhazikika, ndipo wogwiritsa ntchito akhoza kuyika deta yofanana ndi alamu malinga ndi malamulo.
●Anti-electromagnetic interference circuit, yodalirika kwambiri.
●Ikhoza kukulitsa kulankhulana kwa USB, kulankhulana kosalekeza, ndi ma modules oyankhulana opanda zingwe, ndipo imatha kuzindikira ntchito zolankhulana ndi kusindikiza za PC.(Mwasankha)
●Kuwunika ndikuwonetsa momwe mpweya wa okosijeni ulili m'chilengedwe.
●SF6 kuwunika zomwe zili ndi gasi ndikuwonetsa ntchito zachilengedwe.
●Ntchito yowonetsera kutentha kwa chilengedwe ndi chinyezi.
●Hypoxia alarm ntchito.
●SF6 ili ndi gasi yopitilira ma alarm.
●Nthawi zonse utsi ntchito.
●Zomwe zili mu Hypoxia kapena SF6 zimapitilira muyeso, kukakamizidwa kutulutsa ntchito.
●Manual kukakamizidwa utsi ntchito.
●Ntchito yomaliza yowonetsera yomaliza.
●Chiwonetsero cha nthawi yeniyeni cha ntchito zosiyanasiyana za parameter.
●Ntchito yamafunso a mbiri yakale.
●Ntchito yapadera yatsiku ndi tsiku ya zero calibration, imagonjetsa zokha ma alarm abodza.
●Nthawi yoyendera yosinthika ndi ogwiritsa ntchito.Limbikitsani zokha ntchito yolondolera ya malo okayikitsa ozindikira.
●Alamu ikachitika, fani ndi ma alarm ndi ma alarm amangoyatsidwa.
●Ogwiritsa ntchito amatha kusintha magawo a alamu a SF6 ndi O2
●Thandizani ntchito yakutali ya RTU.
●Misa alamu deta mbiri yosungirako ntchito, moyo wautali kupanga
●Pongowonjezera mtengo wochepa, malo ozindikira amatha kuwirikiza kawiri kuti awonjezere kuchuluka kwa kuzindikira.
●Kupanga kwamphamvu kwamphamvu 185-250VAC, anti-surge ndi ntchito yamphezi.
●Kulowetsedwa kwa thupi laumunthu, yambitsani fan kapena mawu
●Chiwonetserocho chimakhala chokhazikika ndipo chimathetsa vuto la kusuntha kwa data.
●Lumikizanani ndi PC kuti mukwaniritse kuwunika kwakutali, ndikujambulitsa zochitika ndi mbiri yakale.
●Kukula kwa omvera: 400 × 300 × 200
●SF6 yodziwika bwino: 0-1500ppm
kukhudzika: ± 5% kuyika mtengo
●Kuzindikira kuchuluka kwa oxygen: 0-25%
●Kulondola kwa kuyeza kwa okosijeni: <0.5% (0.4%, O2 pa 21%)
●Hypoxia alarm threshold: 18.0% (yosinthika)
●Kutentha kowonetsera osiyanasiyana: -20--99 ℃
●Chinyezi chowonetsera: 0--99% RH
●Malo odziwikiratu: Malinga ndi momwe zilili pamalopo
●Ntchito yojambulira deta: kujambula zokha zochitika za alamu, kusungirako anthu ambiri, ndikusintha zokha.
●Kutulutsa kwa Alamu: Kutulutsa kolumikizana kopanda ntchito, kumatha kulumikizidwa ndi RTU, ndikuthandizira kutulutsa kwa alamu kwa RS485.
●Thandizani ntchito ya RTU yoyambira kutali.
●Kuthandizira kuzindikirika kwa thupi la munthu, yambitsani fani kapena kuthamangitsa mawu.
●Wowongolera mafani:
Sinthani mtundu: wongolerani mphamvu za fan.
Mtundu wa Pulse: Imalumikizidwa ndi switch yowongolera mafani;ikhoza kusankhidwa malinga ndi momwe zilili pa tsamba.
●Kuyamba kwa fan kumathandizira mitundu ingapo: kuyambira nthawi, kuyambitsa alamu, kungoyambira pakakhala wina, kuyambika kwakutali, kuyambika pamanja, ndi zina zambiri.
●Kusankhira mitundu yagawo lalikulu: zotchinga pakhoma / 3U / 19-inch standard kesi kapena 10-inch touch Android style mawonekedwe.(kwa mwina.)
●Thandizani kufalitsa kwakutali kwa data yoyezera kudzera pa RS485.Mwachitsanzo, ikani chiwonetsero chachikulu cha LED pachitseko, ndipo nthawi yomweyo muwone magawo amiyeso ndi magwiridwe antchito patali (zosankha ndi wogwiritsa ntchito)