GDYB-D24 Single Phase Energy Meter Test System
●Kupanga koyenera komanso mawonekedwe okongola.Chipangizo chopachikidwa patebulo ndi tebulo la thupi la tebulo zonse zimapangidwa ndi zipangizo zapadera za aluminiyamu, ndipo pamwamba pa tebulo amapangidwa ndi zipangizo zotetezera moto komanso zosagwira kutentha.Chipangizo chonsecho chili ndi mitundu yofewa, magawo ogwirizana, komanso mawonekedwe odalirika.Luso laluso, mawonekedwe okongola.
●Odzipatulira kiyibodi ntchito ndi PC ntchito pali, yosavuta kugwiritsa ntchito.Chipangizochi chili ndi kiyibodi, kiyibodi imabwera ndi mawonekedwe amadzimadzi a kristalo, ndipo mawonekedwe ogwirira ntchito a chipangizocho amamveka bwino mukangoyang'ana.Ntchitoyi ndi yosavuta komanso yaulere.Pulogalamu yoyang'anira PC ili ndi magawo omveka bwino, mawonekedwe okongola, komanso kugwiritsa ntchito kosavuta komanso kosavuta.
●Madigiri apamwamba a automation.Mukatsimikizira mita yamphamvu yamagetsi, muyenera kungotenga nawo gawo pawotchi, kusintha chitsanzo cha photoelectric, ndikupanga bwino magawo a mita, zinthu zonse zotsimikizira (kuphatikiza kutenthedwa, kuyeserera, kuyesa koyambira, kutsimikiza kwapatuka, ndi kutsimikiza zolakwika) ) Imayendetsedwa ndi PC ndikumalizidwa nthawi imodzi.Njira yowongolera ikhoza kukhala yogwirizana ndi malamulo adziko kapena ikhoza kusinthidwa ndi wogwiritsa ntchito.
●Chitsanzo cha photoelectric chimatha kuzindikira kusintha kwa mbali zitatu, ndipo chimatha kuyesa chizindikiro chotembenuka cha mita yamagetsi yamagetsi.Ikhozanso kulandira chizindikiro cha stroboscopic cha mita yamagetsi yamagetsi.
●Makina opangira zolakwika amatha kulandira chizindikiro cha photoelectric sampler, kutulutsa kwamphamvu kwa mita yamagetsi okwera komanso chizindikiro champhamvu champhamvu chamagetsi.
●Mamita amphamvu amtundu womwewo (ma voliyumu omwewo adavotera ndi ma calibration pano) ndi zosintha zosiyanasiyana zimatha kusinthidwa nthawi imodzi (zochepa mpaka zokhazikika ziwiri).
●Itha kupeza yokha chizindikiro chakuda cha mita ya mphamvu yamagetsi yozungulira, yomwe ndiyosavuta kuyesa (kuyambira).
●2 mpaka 21 ma harmonics amatha kuyikidwa pamwamba pa mafunde amphamvu pafupipafupi, ndipo matalikidwe ndi gawo la ma harmonics amatha kukhazikitsidwa ngati pakufunika.Ikhozanso kusanthula ma harmonic pazomwe zimatuluka ndikujambula mawonekedwe ake.
●Chipangizocho chili ndi kukhazikika kwakukulu, kudalirika kwabwino komanso mphamvu yayikulu yotulutsa.Mphamvu yamagetsi (yapano) imatha kunyamula katundu wamtundu uliwonse.
●Kuzindikira zolakwika kwathunthu, malo, chitetezo ndi ntchito za alamu kuti mupewe kuwonongeka kwa chipangizocho chifukwa cha mawaya opangidwa ndi anthu kapena zolakwika zantchito.
●Mapulogalamu oyang'anira ma PC alinso ndi ntchito monga kusindikiza lipoti lathunthu, ziwerengero zamasamu ndi kukonza katundu.
Kulondola kwadongosolo: 0.05%, 0.1%.
●Mphamvu yotulutsa: 220V, yosinthika: (0% ~ 120%)x yoyezera, kusintha kosinthika: bwino kuposa 0.01%.
●Mayendedwe apano: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A.mtundu wosinthika: (0% ~ 120%) x kuyeza, kusintha kosinthika: bwino kuposa 0.01%.
●Mphamvu yotulutsa: voltage loop: 300VA, loop pano: 500VA.
●Kukhazikika kwamagetsi otulutsa, apano ndi mphamvu:
≤0.02%/120S PF=1 (Kalasi 0.05)
≤0.05%/120S PF=1 (Kalasi 0.1)
●Kusokonekera kwa mafunde amagetsi otulutsa ndi apano: ≤0.5%
●Mafupipafupi osiyanasiyana: 45Hz-65Hz kulondola kowongolera: 0.01Hz
●Kusuntha kwa gawo: -180.0 ° ~ 180.0 ° kulondola kowongolera: 0.01°
●Kuwonetsa kalasi ya zida
●Kulondola kwa voltmeter: mlingo ± 0.2%
●Ammeter yolondola mulingo ± 0.5%
●Kulondola kwa mita ya gawo: ± 0.5 °
●Kulondola kwa mita pafupipafupi: ± 0.1Hz
●Maximum mita poyesa: 12pieces
●Mphamvu: 220V ± 10%, 50Hz (kapena 120V ± 10%, 60Hz)
●Kugwiritsa ntchito mphamvu kwambiri: 800VA
●Kutentha kwa ntchito: 20 ± 5 ℃ chinyezi wachibale: ≤85%
●Makulidwe ndi kulemera: 2000mm * 720 mm * 1550mm 280Kg