GDOT-80A Insulation Mafuta Tester
●Chonde werengani bukuli mosamala musanagwiritse ntchito.
●Chonde onani ngati woyesayo alumikizidwa bwino padziko lapansi musanayese.
●Ndizoletsedwa kusuntha kapena kukweza chivundikiro choyesera poyesa kuti tipewe kuvulazidwa ndi mphamvu zambiri.Mphamvu ziyenera kuzimitsidwa musanalowe m'malo mwa mafuta a zitsanzo.
●Gwirani mosamala mukanyamuka kapena kutseka chivundikiro choyesera ma voltage apamwamba!
●Ngati choyesa chikugwira ntchito molakwika mafuta otsekereza atayika, chonde zimitsani choyesa kwa masekondi 10, ndikuyambiranso.
●Mapepala osindikizira akatha, chonde onani gawo lofotokozera chosindikizira (kapena chowonjezera pamanja) kuti musinthe pepala losindikiza kuti mupewe kuwonongeka kwa mutu wosindikiza.
●Sungani choyesa kutali ndi chinyezi, fumbi ndi zinthu zina zowononga, ndikuchisunga kutali ndi kutentha kwakukulu.
●Gwirani mosamala mumayendedwe.Osayika mmwamba mbali pansi.
●Bukhuli likhoza kukonzanso moyenerera popanda chidziwitso china pasadakhale.Ngati muli ndi funso, chonde titumizireni.
Nthawi ya chitsimikizo cha mndandandawu ndi chaka chimodzi kuyambira tsiku lotumizidwa.Chonde onani invoice yanu kapena zikalata zotumizira kuti mudziwe masiku oyenera a chitsimikizo.HVHIPOT corporation ikupereka chitsimikizo kwa wogula woyambirira kuti chinthuchi sichikhala ndi zolakwika pazakuthupi ndi kapangidwe kake pakagwiritsidwe ntchito bwino.Munthawi yonse yachitsimikizo, perekani kuti zolakwika zotere sizinatsimikizidwe ndi HVHIPOT kuti zidayamba chifukwa cha nkhanza, kugwiritsa ntchito molakwika, kusintha, kuyika molakwika, kunyalanyaza kapena kuwononga chilengedwe, HVHIPOT ili ndi malire pakukonza kapena kusintha chida ichi panthawi yachitsimikizo.
GDOT-80C chida | 1 pc |
Chikho chamafuta (250ml) | 1 pcs |
Chingwe champhamvu | 1 pc |
Fuse yapakati | 2 ma PC |
Ndodo yogwedeza | 2 ma PC |
Standard gauge (25mm) | 1 pc |
Sindikizani pepala | 2 mitu |
Tweezer | 1 pc |
Wogwiritsa ntchito | 1 pc |
Lipoti la mayeso a fakitale | 1 pc |
HV Hipot Electric Co., Ltd. yawerengera mosamalitsa komanso mosamala bukuli, koma sitingatsimikizire kuti palibe zolakwika ndi zosiyidwa kwathunthu m'bukuli.
HV Hipot Electric Co., Ltd. yadzipereka kupititsa patsogolo ntchito zogulitsa, ndikuwongolera magwiridwe antchito, motero kampaniyo ikhalabe ndi ufulu wosintha zinthu zilizonse ndi mapulogalamu apulogalamu omwe afotokozedwa m'bukuli komanso zomwe zili m'bukuli popanda kuyambiranso. zindikirani.
Kutsekera kwamkati kwa zida zamagetsi zambiri zamakina amagetsi, masitima apamtunda, mafakitole akuluakulu a petrochemical ndi mabizinesi, nthawi zambiri amatengera mtundu wamafuta odzaza mafuta, chifukwa chake, kuyesa kwamphamvu kwa dielectric mphamvu yamafuta ndikofala komanso kofunikira.Kuti tikwaniritse zosowa za msika, tapanga ndi kupanga zoyesa zoyesa mphamvu zamafuta a dielectric motsatana ndi mtundu wa GB/T507-2002, muyezo wamakampani DL429.9-91 ndi Electric Power Viwanda Standard DL/T846.7 -2004 tokha.Chida ichi, pogwiritsa ntchito kachipangizo kakang'ono kachipangizo kakang'ono kamene kamayambira, chimazindikira ntchito yodziwikiratu, kuyeza kolondola kwambiri, kuwongolera bwino ntchito ndikuchepetsa kulimbikira kwa ogwira ntchito.Komanso, ndi yaying'ono kukula kwake komanso yabwino kunyamula.
●Ndi microprocessor, kwaniritsani zokha kuyesa kwa voliyumu kwa kayendedwe ka mafuta kosiyanasiyana kwa 0 ~ 80KV (kuphatikiza kulimbikitsa, kusamalira, kusakaniza, kuyimirira, kuwerengera, kusindikiza ndi ntchito zina).
●Chiwonetsero chachikulu cha LCD.
●Ntchito yosavuta.Makinawa amangomaliza kuyesa kuyesa kwamagetsi pa kapu imodzi yamafuta amafuta pambuyo pa kukhazikitsidwa kosavuta ndi woyendetsa.Mtengo wamagetsi owonongeka wa 1 ~ 6 nthawi ndi nthawi zozungulira zidzasungidwa zokha.Pambuyo pa mayesowo, chosindikizira chotenthetsera chidzasindikiza mtengo uliwonse wosweka ndi mtengo wapakati.
●Mphamvu-pansi kuteteza.Chithasungani zotsatira zoyesa 100 ndikuwonetsa kutentha ndi chinyezi.
●Adopt single-chip microcomputer kuti mukweze voteji pa liwiro lokhazikika.Ma frequency a voltage ndi olondola pa 50HZ, onetsetsani kuti njira yonseyo ndiyosavuta kuwongolera.
●Ndi over-voltage, over-current and limit protection kuonetsetsa chitetezo cha ogwira ntchito.
●Ndi ntchito ya kusonyeza kutentha kuyeza ndi wotchi dongosolo.
●Lumikizanani ndi kompyuta ndi mawonekedwe a RS232.
Magetsi | AC220V ± 10%, 50Hz |
Mphamvu yamagetsi | 0~80kv ku(Zosankhika) |
Mphamvu | 1.5kVA |
Mphamvu | 200W |
Kuthamanga kwamagetsi kumawonjezeka | 2.0~3.5k kuV/s (Zosintha) |
Votejikuyezakulondola | ±3% |
Kusokonezeka kwa Waveform | ≤3% |
Nthawi yowonjezera | 5min (Zosinthika) |
Nthawi yoyima | 15min (Zosintha) |
Nthawi zowonjezera | 1~6 (Zosankhika) |
Kuchitachilengedwe | Tkutentha: 0 ℃-45℃ |
Hpakati:Max.chinyezi chachibale75% | |
Dimension | 465x385x425mm |