HV-OWS-63 Oscillating Wave Test System (OWTS) ya Pamalo a PD Diagnostics of Cables
1. Mndandanda wa HV-OWS ndi njira yoyeserera yoyeserera pang'ono, yomwe imagwiritsidwa ntchito makamaka pakuzindikira kutulutsa pang'ono kwa zingwe zapakati pamagetsi.Ma frequency oyeserera amachitidwe ndi 50Hz mpaka mazana angapo a Hz damping AC voteji, voteji yonyowa ya AC yopangidwa ndi dongosolo panthawi yoyeserera imatha kufika 60kV, ndipo imaphatikizidwa ndi zida zapamwamba zamakina ndi pulogalamu yamapulogalamu yowunikira.
● Ukadaulo waposachedwa kwambiri wamagetsi opangira semiconductor
● Ukadaulo waposachedwa wa laser control
● Makina opangira ma siginolo a digito ndiukadaulo wosefa
●Ukadaulo waukadaulo wowongolera ma netiweki opanda zingwe.
2. Pulogalamu yoyezera ndi kusanthula ikhoza kusanthula deta yakutali pansi pa chikhalidwe cha intaneti.
3. Chingelezi chathunthu cha opareshoni, chotha kujambula ma oscillating ma waveform ndi ma waveforms otulutsa pang'ono, ndikupanga madontho a nthawi yeniyeni panthawi yokakamiza;
4. Kuwonetseratu pafupipafupi, matalikidwe ndi zitsanzo nthawi m'lifupi mwa oscillating voteji waveform.
5. Ikhoza kusanthula yokha kufalikira kwa mawonekedwe a mafunde oyesedwa.
6. Onetsani zodziwikiratu mtengo woyesera wotayika wa dielectric.
7. Pangani zokha mapu a malo otayika pang'ono ndikupanga malipoti a ziwerengero, ndikupanga mapu owerengera pang'ono.
Mphamvu yamagetsi | Kuchuluka: ± 60kVnsonga |
Oscillation frequency range | 20Hz ~ 850Hz |
Inductance | 1.0H ~ 2.1H (posankha) |
Kusanthula deta | Kusanthula pamanja, kusanthula zokha (kusefa kwa analogi ndi digito) |
Kukhoza kuyeza | 0.05 ~ 5uF |
Kuthamanga kwamagetsi apamwamba | 10mA |
Mulingo woyezetsa pang'ono | 10pC ~ 200nC |
Kulondola kwa miyeso | ± 0.1pC (chitsanzo 14bits) |
Liwiro la mafunde | 50-300m / ife |
Kupeza kulondola | ± 0.1m |
Kupeza cholakwika | ≤1% × kutalika kwa chingwe |
Kuzindikira kwa PD | Malinga ndi IEC60270 |
PD kupeza bandwidth | 100kHZ~50MHZ zodziwikiratu kapena kusankha pamanja |
Kutayika kwa dielectric tani δ | 0.1% ~ 10% |
Mphamvu yamagetsi | 180V ~ 250V, AC 50Hz |
Kutentha kwa ntchito | -120 ℃ ~ + 60 ℃ |
Kulemera | Pafupifupi 88kg |
Kukula | Diameter 650mm, kutalika 980mm |
Chiyankhulo | WLAN (IEEE802.11g)/100M Efaneti khadi |
Ayi. | Dzina | Qty. |
1 | HV-OWS-63 oscillating wave test system main unit | 1 seti |
2 | Makompyuta a Notebook (omwe ali ndi mayeso opangidwa ndi oscillating wave partial discharge test and analysis software system) | 1 seti |
3 | Capacitor yakunja yamalipiro | 1 seti |
4 | Jenereta yowongoka yamphamvu kwambiri ya pulse calibration | 1 seti |
5 | High voltage test cable | 1 seti |
6 | High-voltage cholumikizira chingwe (kulumikiza compensation capacitors) | 1 seti |
7 | Calibration pulse jenereta chingwe (imodzi yofiira ndi ina yakuda) | 2 ma PC |
8 | Control kupeza chingwe | 1 pc |
9 | Chingwe cholumikizira netiweki (chokhala ndi doko la netiweki kupita ku mtundu-c module) | 1 pc |
10 | Waya wapansi | 1 pc |
11 | Ndodo yapansi | 1 pc |
12 | Chingwe chamagetsi | 1 pc |
13 | Chalk waya paketi | 1 pc |
14 | Buku la ntchito | 1 kopi |
15 | Chitsimikizo / Chitsimikizo khadi | 1 kopi |
16 | Mndandanda wazolongedza | 1 kopi |