GD2000H 10kV Insulation Resistance Tester
Chipangizochi chimatha kuyesa kukana kwa kutchinjiriza (monga thiransifoma, switchgear, lead, motor) yama module osiyanasiyana mu dongosolo limodzi, kuti insulate ndi kukonza zida zolephera.
Ndikofunikira kuonetsetsa kuti zinthu zili bwino komanso chitetezo cha munthu ndi zida panthawi yogwira ntchito poyesa kuyesa kuyesa chinthu choyezera pansi kapena moyandikana ndi ma conductor.
Musanayambe mphamvu pamakina, gwiritsani ntchito kuyesa kwa insulation kuti muwone ngati kuli bwino kukonza magwiridwe antchito.Kuyesa kwa insulation ndikupeza zovuta pakupangira zida ndi vuto la zida zomwe sizingapezeke kulephera kusanachitike.Ku EU, kuyesaku ndikokakamiza, ngakhale ku boma.
1. Kutulutsa kwamagetsi kwa GD2000H (5kV/10kV) .Kukana kusiyanasiyana 0-400GΩ.
2. Mitundu iwiri imawonetsa kukana kwa insulation.
3. Auto-calculating absorption ratio ndi polarization index.
4. Ntchito mwaubwenzi, kupulumutsa mosalekeza 19times muyeso zotsatira.
5. Auto-discharge residual high voltage after mayeso atha.
6. Mphamvu yamagetsi ya AC / DC, yokhala ndi batri yowonjezereka kapena AC adaputala.
7. Kukhoza kwamphamvu kotsutsa kusokoneza, kuwerenga kokhazikika komanso kodalirika.
8. Mapangidwe onyamula, oyenera ntchito zakutchire.
9. Short-circuit current ≥3.5mA, zida zabwino zoyesera kukana kutchinjiriza kwa thiransifoma yayikulu, inductor, jenereta, ma HV motors, capacitor yamagetsi, zingwe ndi surge arrester.
KanthuChitsanzo | GD2000H | ||
Mphamvu yamagetsi | 5kV DC | 10k paV DC | |
Kulondola | Kutentha | 23℃±5℃ | |
Insulation resistance | 5M ~ 100G ±5% | 10M ~ 200G ±5% | |
Mtundu wina: ± 10% | |||
Mphamvu yamagetsi | 40M ~ 200G 0 ~ + 10% | 80M-400GΩ pa 0-+10% | |
Short-circuit current | ≥3.5mA | ||
Magetsi | 8 *Batire yamtundu wa AA yokwera kwambiri komanso adapter yakunja | ||
Kutentha kwa Ntchito. & Chinyezi | -10 ℃--40 ℃, max.relative chinyezi 85% | ||
Kutentha Kosungirako.& Chinyezi | -20 ℃--60 ℃, max.relative chinyezi 90% | ||
Insulation | Max.20000MΩ pamene voteji pakati pa dera ndi chipolopolo ndi 1000VDC. | ||
Kupirira voltage | Kupirira 1min pamene voteji pakati dera ndi chipolopolo ndi3kV / 50HzAC | ||
Dimension | 230mm*190mm*90mm (L*W*H) | ||
Kulemera | 3kg pa | ||
Zida | Mayeso otsogolera, pamanja, chosinthira chowonjezera, chingwe chamagetsi, lipoti loyesa |
Insulation resistance tester | 1 seti |
Yesani waya | 1 chidutswa |
Adaputala yamagetsi | 1 chidutswa |
Chingwe champhamvu | 1 chidutswa |
Buku Logwiritsa Ntchito | 1 kopi |
Satifiketi | 1 kopi |