Zogulitsa

  • GDUP-3000 Pure Sine Wave AC Power Supply

    GDUP-3000 Pure Sine Wave AC Power Supply

    GDUP-3000 ndi mphamvu yosunthika yosasunthika ya sine wave pamalo oyeserera a AC.Zomwe zimadziwikanso kuti pamasamba a AC ndi DC kuyesa magetsi, magetsi adzidzidzi a AC ndi DC, magetsi oyesa kumunda, magetsi oyesa mafoni.

  • GDUP-1000 Versatile Portable Pure Sine Wave Pamalo a AC Test Power Supply

    GDUP-1000 Versatile Portable Pure Sine Wave Pamalo a AC Test Power Supply

    GDUP-1000 ndi mawonekedwe osunthika osunthika a sine wave pamalo oyeserera a AC.Zomwe zimadziwikanso kuti pamasamba a AC ndi DC kuyesa magetsi, magetsi adzidzidzi a AC ndi DC, magetsi oyesa kumunda, magetsi oyesa mafoni.

  • GDC-9560B Power System Insulation Mafuta Gasi Chromatograph Analyzer

    GDC-9560B Power System Insulation Mafuta Gasi Chromatograph Analyzer

    GDC-9560B Gas Chromatograph Analyzer ndikuwunika momwe mafuta amapangira mafuta pogwiritsa ntchito njira ya gasi chromatographic.Ndizothandiza kuweruza ngati zida zogwiritsira ntchito zili ndi vuto ngati kutentha kwambiri, kutulutsa kapena ayi, kuonetsetsa chitetezo cha gridi yamagetsi.

  • GDOH-II Insulating Oil Gas Content Tester

    GDOH-II Insulating Oil Gas Content Tester

    GDOH-II Insulating Oil Gas Content Tester ndi choyesa cham'badwo chatsopano chomwe chimatengera sensor yolondola kwambiri komanso ukadaulo waposachedwa kwambiri.Zimatengera mulingo wamakampani amagetsi a DL423-91 komanso miyezo yoyenera yadziko.

  • GDW-102 Mafuta Dew Point Tester (Coulometric Karl Fischer Titrator)

    GDW-102 Mafuta Dew Point Tester (Coulometric Karl Fischer Titrator)

    Ukadaulo wa Coulometric Karl Fischer umagwiritsidwa ntchito kuyeza ndendende chinyezi chomwe chimayezedwa chomwe chilipo. Ukadaulo umagwiritsidwa ntchito kwambiri pakulondola komanso mtengo wotsika mtengo woyeserera. The Model GDW-102 muyeso amafufuza ndendende chinyezi pamadzi, olimba ndi gasi zitsanzo malinga ndi luso.

  • GDBS-305 Automatic Flash Point Closed Cup Tester

    GDBS-305 Automatic Flash Point Closed Cup Tester

    GDBS-305 automatic automatic cup flash point tester ndi chipangizo choyesera chotsekera kapu yamafuta amafuta.Imagwiritsa ntchito kapangidwe ka module komwe munthu m'modzi amatha kuwongolera ng'anjo zingapo zoyesera, kuyesa zitsanzo zosiyanasiyana nthawi imodzi kapena padera.

  • GDZD-601 Automatic Multi-Function Insulation Oil Shaker

    GDZD-601 Automatic Multi-Function Insulation Oil Shaker

    Multi-Function Shaker imagwiritsidwa ntchito mu labotale kuyesa kutentha, kugwedeza, degas mitundu yosiyanasiyana yamadzimadzi pansi pa kutentha kosalekeza komanso nthawi yokhazikika.Imayendetsedwa ndi makompyuta ang'onoang'ono kuti azindikire kulumikizana kwa makina amunthu.

  • Mayeso a AC High Voltage a GIS

    Mayeso a AC High Voltage a GIS

    AC Resonant Test System ya Substation Electrical Equipment, imapangidwa makamaka ndi ma frequency frequency magetsi, Excitation Transformers, Reactors, Capacitive dividers, yomwe idapangidwira AC kupirira mayeso amagetsi amagetsi apansi pa 500kV kapena pansi.

     

     

  • PD Free Variable Frequency Test System

    PD Free Variable Frequency Test System

    GDYT-350kVA/70kV PD Free Resonant Test System imapangidwa ndi PD free variable frequency power supply, HV kuyeza bokosi, excitation transformer, isolation transformer, Resonant reactor, ndi capacitive voltage divider.

     

     

     

     

     

     

  • Kuyesa kwa Hipot Kukhazikitsa Ndi Kuwongolera Mwadzidzidzi

    Kuyesa kwa Hipot Kukhazikitsa Ndi Kuwongolera Mwadzidzidzi

    Kuyesa kwa AC hi-pot ndiye njira yothandiza komanso yolunjika yoyesera mphamvu ya kutchinjiriza pazida zamagetsi, zida kapena makina.Imawunika zolakwika zowopsa zomwe zimatsimikizira kuti zida zamagetsi zikugwira ntchito mosalekeza.

  • Battery Impedance Tester GDBT-8612

    Battery Impedance Tester GDBT-8612

    Monga chigawo chachikulu cha mphamvu zamagetsi, mabatire ayenera kuyesedwa ndi kusungidwa chaka ndi chaka, kotala kapena mwezi uliwonse ndipo deta yawo yoyesera iyenera kufufuzidwa nthawi zonse.

  • GDZRS-20A Three Phase DC Winding Resistance Tester

    GDZRS-20A Three Phase DC Winding Resistance Tester

    Choyesa chofulumira cha DC ichi (chomwe chimatchedwa kuti DC winding resistance tester) ndiye chida chaposachedwa kwambiri choyezera kukana kwa DC kwa ma transformer.Imakonzedwa kuti iyeze kukana kwa DC kwa magawo atatu a ma windings a ma transfoma akuluakulu.Kukaniza kwa DC kwa ma windings a magawo atatu a transformer kumatha kuyesedwa nthawi imodzi.Pakuti pa-katundu voteji yoyendetsera thiransifoma, si koyenera kutulutsa chosinthira wapampopi mwachindunji, ndipo nthawi muyeso ndi gawo limodzi mwa magawo atatu a miyambo chikhalidwe gawo limodzi muyeso, amene angafupikitse kwambiri nthawi yogwira ntchito ndi mphamvu ya ntchito.Mamita okanira mwachindunji amatengera chiwonetsero chachikulu chamadzimadzi chamadzimadzi chokhala ndi skrini, mawonekedwe onse aku China, omveka bwino komanso mwachilengedwe, ndipo ntchitoyo ndiyosavuta.Ndipo pokhala ndi chosindikizira chamagulu ndi kukumbukira kwakukulu kosasunthika, mukhoza kusunga ndi kusindikiza zotsatira zake.Zomwe zimayesedwa ndizokhazikika, zachangu komanso zobwerezabwereza, ndipo ndiye chisankho chabwino kwambiri choyezera kukana kwa DC kwa ma transformer pamalopo.

Titumizireni uthenga wanu:

Lembani uthenga wanu apa ndikutumiza kwa ife