  • GDBS-305A Automatic Flash Point Closed Cup Tester

    GDBS-305A Automatic Flash Point Closed Cup Tester

    GDBS-305A automatic automatic cup flash point tester ndi chipangizo choyesera chotsekera kapu yamafuta amafuta.Amagwiritsidwa ntchito kwambiri pantchito ya njanji, ndege, mphamvu, mafuta, ndi dipatimenti yofufuza.

  • GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205A Automatic Flash Point Open Cup Tester

    GDKS-205Azokhatsegulanicup flash point tester ndiye kuyesa kwa chipangizotsegulanikapu flash point yamafuta amafuta.Imagwiritsa ntchito kapangidwe ka module komwe munthu m'modzi amatha kuwongolera ng'anjo zingapo zoyesera, kuyesa zitsanzo zosiyanasiyana nthawi imodzi kapena padera.Doko la ng'anjo yoyesera limatha kulumikizidwa ndi wolandila mosasamala. Amagwiritsidwa ntchito kwambiri pantchito ya njanji, ndege, mphamvu, mafuta ndi dipatimenti yofufuza.

  • GDJF-2008 Partial Discharge Analyzer

    GDJF-2008 Partial Discharge Analyzer

    GDJF-2008 Partial Discharge Detector ikuyesa kutulutsa pang'ono kwa zinthu monga zosinthira, ma inductors, masiwichi a HV, zomangira zinc monoxide ndi zingwe zamagetsi.Ithanso kupanga mayeso amtundu ndikuyang'anira ntchito yotsekera.

  • GDBT-8610P Battery Impedance Tester

    GDBT-8610P Battery Impedance Tester

    GDBT-8610P ndi m'badwo watsopano woyesa batire wokhala ndi zowonera.Amapangidwa kuti aziwunika ndikusunga mphamvu zonse zoyima kuphatikiza Uninterruptible Power System.

    Kupyolera mu kuyesa kolondola kwa kukana ndi magetsi, kumapereka chisonyezero cha mphamvu ya batri ndi luso lamakono.Deta yoyezera imatha kuwerengedwa pa chiwonetsero cha chida mwachindunji.Ndipo imathanso kukwezedwa ku PC pogwiritsa ntchito USB drive.Ndi pulogalamu yowunikira, simungangosunga zotulukapo zoyezetsa komanso kukhala ndi kusanthula mwatsatanetsatane momwe mabatire alili pamayesero osiyanasiyana.

  • GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)

    GD6100 ndi chida cholondola kwambiri choyesera ma dielectric loss angle and volume resistivity of insulating oil or other insulating liquids.

  • GLF-314 SF6 Gas Infrared Imaging Leak Detector

    GLF-314 SF6 Gas Infrared Imaging Leak Detector

    SF6 infrared imaging leak detector ndi chipangizo chosalumikizana ndi gasi chomwe chimatha kuzindikira kutuluka kwa mpweya pamamita angapo kapena makumi a mita.Imatha kuyang'ana mwachangu malo akulu ozindikira ndikupeza zotayira molondola munthawi yeniyeni.

    Chojambula chozindikira kutentha kwa gasi chimatha kuzindikira kutayikira kapena kutulutsa kosalongosoka kwa organic volatiles, ndipo chimagwirabe ntchito bwino ngakhale pakutulutsa pang'ono kwa gasi.

    Kugwiritsidwa ntchito kwa kutulutsa mpweya wa gasi ndi njira yabwino komanso yodalirika, yomwe imatha kuzindikira kutuluka kwa gasi wachilengedwe m'magulu osiyanasiyana monga mayendedwe, kusungirako ndi kupanga, kuti apititse patsogolo chitetezo ndikusunga ndalama.

  • GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    Pali zida zambiri zamagetsi mumagetsi, njanji ndi migodi yayikulu yamafuta a petrochemical ndi mabizinesi, kutchinjiriza kwawo kwamkati kumakhala kodzaza ndi mafuta.Mphamvu ya dielectric yamafuta otsekera ndikuyesa kovomerezeka.Pofuna kukwaniritsa zosowa za msika, kampani yathu idapanga ndikutulutsa makina oyesa mphamvu yamafuta a dielectric molingana ndi muyezo wadziko lonse wa GB/T507-2002(IEC156), DL429.9-91 komanso mulingo waposachedwa kwambiri wamakampani opanga magetsi. DL/T846.7-2004.Chidachi chimatenga kachipangizo kakang'ono kachipangizo kakang'ono kamene kamayambira, chimazindikira zonse zomwe zimayesedwa, zimakhala zolondola kwambiri, zimathandizira kwambiri magwiridwe antchito, komanso zimachepetsa kwambiri kulimbikira kwa ogwira ntchito.Nthawi yomweyo, chidacho chimakhala ndi mawonekedwe ophatikizika ndipo ndichosavuta kunyamula.

  • GDOT-80A Insulation Mafuta Tester

    GDOT-80A Insulation Mafuta Tester

    Chonde werengani bukuli mosamala musanagwiritse ntchito.
    Chonde onani ngati woyesayo alumikizidwa bwino padziko lapansi musanayese.
    Ndizoletsedwa kusuntha kapena kukweza chivundikiro choyesera poyesa kuti tipewe kuvulazidwa ndi mphamvu zambiri.Mphamvu ziyenera kuzimitsidwa musanalowe m'malo mwa mafuta a zitsanzo.

  • GDKC-5000 Transformer Pa Load Tap Changer Tester

    GDKC-5000 Transformer Pa Load Tap Changer Tester

    GDKC-5000 Transformer On Load Tap Changer Tester imatha kuyeza molondola nthawi yocheperako, mawonekedwe osakhalitsa, kukana kwakanthawi, kulumikizana kwa magawo atatu ndi magawo ena a chosinthira chotsitsa.Ndi chida choyenera kuyesa chosinthira chapampopi.Imakwaniritsa zofunikira pakuwunika kachitidwe kakusintha kwapampopi ndi kuyeza nthawi yosinthira.

     

  • GD-875/877 Thermal Infrared Camera

    GD-875/877 Thermal Infrared Camera

    GD-875/877 infuraredi kamera amagwiritsa 25μm 160 * 120 chowunikira, kutentha muyeso osiyanasiyana -20 ℃–+ 350,3.5inch TFT LCD chophimba.

     

    Kugwiritsa ntchito

     

    Kusamalira koteteza

    • Makampani amagetsi: Chingwe chamagetsi ndi malo opangira magetsi opangira kutentha;kuzindikira cholakwika ndi cholakwika.
    • Dongosolo lamagetsi: Dziwitsanitu kudzaza dera kusanachitike
    • Makina amakina: Chepetsani nthawi yopuma ndikupewa kulephera kowopsa.

    Sayansi yomanga

    • Padenga: Kuzindikiritsa mwachangu mavuto olowa m'madzi.
    • Kapangidwe: Kuwunika kwamphamvu zamalonda ndi zogona.
    • Kuzindikira chinyezi: Dziwani chomwe chimayambitsa chinyezi ndi mildew.
    • Kuwunika:Unikani njira zowongolera kuti muwonetsetse kuti malowo ndi ouma.

     

     

  • GDPD-313P Chojambulira Pamanja Chotulutsa Pamanja

    GDPD-313P Chojambulira Pamanja Chotulutsa Pamanja

    Chowunikira chogwiritsira ntchito pamanja chimagwiritsidwa ntchito kuti azindikire ndikuyesa kutulutsa kwamagetsi apansi pompopompo ndi kutulutsa pamwamba mu kabati yosinthira ndikuwonetsa mawonekedwe otulutsa ndikutulutsa mu nthawi yeniyeni pazenera la LCD.Chidacho chimatengera mawonekedwe onyamula mfuti, omwe amatha kufufuzidwa ndikuzindikiridwa mwachindunji pa chipolopolo cha switchgear popanda kuwononga kapena kuwononga magwiridwe antchito a switchgear.Nthawi yomweyo, zizindikiro zoyezedwa zimatha kusungidwa ndikuseweredwanso pa TF khadi.Mahedifoni ofanana amatha kumva phokoso la kutulutsa.

  • GDYZ-302W Metal Oxide Arrester (MOA) Tester

    GDYZ-302W Metal Oxide Arrester (MOA) Tester

    GDYZ-302W Metal Oxide Arrester Tester imapangidwa ndi makamu, chowunikira, ndi ndodo yoteteza.Wolandirayo ndi chojambulira amatengera kulumikizana opanda zingwe, mtunda wolumikizana ndi 30 metres, wolandirayo amatha kutsegula kapena kutseka patali mutu wa chojambulira kuti amalize kuyesa, ndipo wolandirayo amatha kuwonetsa kuchuluka kwa mayeso omwe alipo komanso mawonekedwe a clamp. mutu mu nthawi yeniyeni.Chojambuliracho chimagwiritsa ntchito injini yaying'ono kuyendetsa kutsegula kapena kutseka kwa mutu wamba.Mutu wa clamp umapangidwa ndi permalloy yapamwamba kwambiri, yomwe ili ndi mphamvu zotsutsana ndi kusokoneza ndipo sichikhudzidwa ndi maginito akunja.Chigamulocho ndi chokwera ngati 1uA.Chowunikiracho chimatha kulumikizidwa ndi ndodo yotchingira kuti iyesere zida zomangira zinc oxide pamizere yothamanga kwambiri.Mamita amathanso kugwiritsidwa ntchito ngati chowongolera chapamwamba kwambiri chowongolera pakutayikira.